Clemex PSFilter
12Pages

{{requestButtons}}

Catalog excerpts

Clemex PSFilter - 1

intelligent microscopy PSFilter Cutting Edge Solution in Particulate Analysis

Open the catalog to page 1
Clemex PSFilter - 2

CLEMEX PSFilter CLEMEX intelligent microscopy A Commitment to Excellence in Imaging For 20 years, Clemex has been providing integrated solutions for Image Analysis in microscopy to meet the specific needs of customers worldwide. This is our expertise and our commitment. Clemex is known for its reliability, its high-quality products, and its after-sales service. Clemex goes beyond meeting the needs of its diverse clientele. Clemex PSFilter is used in quality-control laboratories to measure particulates collected on a membrane filter to check for contamination, and on a silicon wafer when...

Open the catalog to page 2
Clemex PSFilter - 3

Intelligent Clemex PSFilter : > Out-of-the-Box Functionality > Ease-of-use > Compliant with International Standards > Used in the automotive, aerospace, medical, and pharmaceutical industries A Commitment to Cleanliness and Quality Control The measuring of particle contamination is of the utmost importance in the manufacturing and pharmaceutical industries. Damage caused by these particles can often have detrimental effects in machinery and harmful effects in pharmaceuticals. That is why the Clemex PSFilter is specially designed to analyze contamination in different areas by measuring...

Open the catalog to page 3
Clemex PSFilter - 4

CLEMEX PSFilter As low as 0.5 micron Our optical systems are stable, reliable, and, once installed, will consistently return accurate, reproducible and certifiable results. If speed is needed, using the Clemex PSFilter with a macroscope will yield results for particles of 5 microns and up. If, on the other hand, image detail is of prime importance, the Clemex PSFilter with a microscope will render particles of 0.5 microns and up. 1. Clemex PSFilter with a microscope and a motorized stage for particles larger than 0.5 micron. 2. Clemex PSFilter with a macroscope and a motorized stage for...

Open the catalog to page 4
Clemex PSFilter - 5

Targeting All the Particles Clemex PSFilter offers an incredible range of properties and customizable parameters that can be used to measure all particles. You can categorize any object by shape, size, color, or texture attributes. With this system you gain a complete understanding of the sample material by generating statistically significant data from information gathered on large numbers of individual particles. The Clemex PSFilter system can handle standard size membrane filters in special sample holders without operator involvement. Large fibers, overlapping fibers, and small dirt...

Open the catalog to page 5
Clemex PSFilter - 6

CLEMEX PSFilter Target Particles in 3 Easy Steps STEP 1 - The Sample Clemex PSFilter accepts different types of samples: membrane filters, wafers, tape lifts, and gel packs. Using specialized holders and an automated stage, the software-controlled microscope or macroscope can scan and map the sample in a few minutes. STEP 2 - Selecting a Standard With its convenient pull-down menus, Clemex PSFilter allows you to choose from pre-programmed International Standards such as IEST STD CC 1246D, ISO 16232, ISO 4406, ISO 4407, or USP 788. Clemex PSFilter also offers the option of customizing its...

Open the catalog to page 6
Clemex PSFilter - 7

STEP 1 The Sample The Clemex PSFilter can analyze different types of samples for different types of purposes. Different Types of Mediums Membrane Filters Membrane filters are used to trap micro particles or micro-organisms within fluid systems. Methods used to determine cleanliness of membrane filters are ISO 4406 & ISO 4407 (for hydraulic fluids), ISO 16232 (for the cleanliness of fluid circuit components in road vehicules), and USP 788 (for injection liquids used in pharmaceuticals). Wafers or Witness Plates Wafers, also referred to as Witness Plates, are used for Particle Fallout...

Open the catalog to page 7
Clemex PSFilter - 8

CLEMEX PSFilter STEP 2 Selecting a Standard* USP 788 The USP 788 standard outlines practices and methods used to measure particle size and count in parenteral preparations. Each method requires a different type of instrumentation and therefore the standard addresses correct sample preparation, instrument calibration for each instrument, and particle size and count specifications. These standards are published by the International Organization for Standardization (ISO) which relate to the contamination of hydraulic fluids by solid particulates. ISO 4406 defines the method used for coding the...

Open the catalog to page 8
Clemex PSFilter - 9

STEP 3 Get Results and Print Everyone has special needs that distinguish their business. We know this and cater to those needs by providing the Clemex Report Generator, a quick and easy way to customize report templates according to internal or industry specific requirements, such as ISO 4406, IEST STD CC1246D and others. Report templates can be tailored to your specifications, to produce either a secure printable report for distribution and review (PDF), or to save to a spreadsheet program for further analysis and calculation. Date: Analyst: Sample ID: Pore size: Sample volume: Covered...

Open the catalog to page 9
Clemex PSFilter - 10

CLEMEX PSFilter Application of Standard USP 788 USP 788 is a standard used in the pharmaceutical industry to classify particulate matter in parenteral injections. Two methods are used to determine the count of undissolved mobile particles unintentionally present in solutions. Clemex PSFilter complies with Method 2 set forth by USP: a microscopic particle count test. Clemex PSFilter is the perfect tool to analyze emulsions, colloids and liposomal preparations. Since these parenteral preparations have reduced clarity they need to be filtered before being analyzed by optical microscopy. Once a...

Open the catalog to page 10
Clemex PSFilter - 11

Application of Standard ISO 16232 ISO 16232 is a standard used to determine the cleanliness of road vehicle components. The life expectancy of automotive parts that are in contact with a liquid is greatly diminished when a high number of small particles are present. This standard is essential in the automotive industry. The vehicle components are first immersed in a liquid that is then collected and filtered with a membrane filter. The filter is then dried and placed in Clemex PSFilter’s specialized holder. Clemex PSFilter scans and maps the filter, all the while counting the particles and...

Open the catalog to page 11