Overview
The Integrated Light & Switchboard (ILS) system is designed to enhance the interface between flame safeguard and combustion equipment, minimizing wiring errors and improving quality. It includes an Integrated Burner Control Subpanel and an LED Switchboard, which provide power, fuel selection, and burner control with visual indications of the burner sequence.
Key Components
  • Integrated Burner Control Subpanel: Connects to the LED Switch Panel and reduces wiring complexity.
  • LED Switch Panel: Mounted on the control panel front, it displays burner sequence and firing rate.
  • Interconnecting Cables: Facilitate communication between components.
Features
  • Multiple Applications: The subpanel design supports various applications, reducing wiring needs.
  • Alarm Silencing: Includes three optically isolated alarm outputs for burner, limit, and auxiliary alarms.
  • Local Remote Switch: Allows burner enable/disable from building management systems.
  • Manual Firing Rate Potentiometer: Enables precise manual burner control.
  • Visual Indication: LEDs indicate power status, call for heat, ignition phase, main fuel status, and alarm conditions.
LED Indicators
  • Power On: White LED indicates control power presence.
  • Call for Heat: White LED signals demand for burner startup.
  • Ignition: White LED shows ignition phase.
  • Main Fuel: Dual-color LED indicates fuel valve status (green for gas, amber for oil).
  • Modulation Indicator: LEDs show firing level (25% white, 50% yellow, 75% blue, 100% green).
Operational Controls
  • Burner Switch: Switches burner between local, off, and remote demand settings.
  • Fuel Select: Allows safe fuel change in dual fuel systems.
  • Modulation Mode: Selects automatic or manual flame control.
  • Manual Flame Control: Potentiometer for adjusting firing rate in manual mode.
  • Alarm Silence: Silences audible alarms while maintaining LED indications.
Technical Specifications
  • Electrical Ratings: 120 Vac, 50/60 Hz.
  • Environmental Ratings: Operating temperature from -40°F to +140°F, storage up to +150°F, 85% humidity.
  • Weight: Burner Control Subpanel: 1 lb., 12 oz.; LED Switch Panel: 4 oz.
  • Approvals: Underwriters Laboratories, Inc. (cULus) listed.
Models Available
  • Single and dual fuel modes: On/Off, Low-High-Low, 135 ohm Full Modulation, 4-20 mA Full Modulation.
See more

Catalog excerpts

Light and Switchboard-1

ILS SYSTEM INTEGRATED LIGHT & SWITCHBOARD

 Open the catalog to page 1
Light and Switchboard-2

Integrated LED Technology Multiple Applications The Integrated Burner Control Subpanel and LED Switchboard provides a wiring interface between the flame safeguard and combustion equipment reducing the potential for wiring errors and improving quality. The LED switch panel is mounted to the front of the control panel and connects to the Integrated Burner Control Subpanel using interconnecting cables. It provides power, fuel selection and auto/manual burner control along with visual indication of the burner sequence. The system consists of the Integrated Burner Control Subpanel, the LED Switch...

 Open the catalog to page 2
Light and Switchboard-3

The LEDs provide the following information: Power On - white LED indicates presence of control power in the subpanel. Call for Heat - white LED indicates that a demand for burner startup is present. Ignition - white LED indicates the burner is in the ignition phase of operation. Main Fuel - Dual color LED that indicates that the main fuel valve(s) are powered. Dual fuel mode: Green light - gas valves are open Amber/Yellow light - oil valves are open Single fuel mode: Amber light only Burner, Limit and Auxiliary Alarm - Red LED indicates what equipment section is in an alarm condition. Modulation...

 Open the catalog to page 3
Light and Switchboard-4

Product Specifications Electrical Ratings Ambient Temperature Ranges: Environmental Ratings CAUTION: Adding external limits or controls will require removal of appropriate terminal jumpers. 250V T5A WARNING:Relays must only be replaced with approved OMRON part# MY2-AC110/120S LED Switch Panel: 4 oz. (124 grams) Burner Control Subpanel: 1 lb., 12 oz. (871 grams) Humidity: 85% relative humidity, continuous, Underwriters Laboratories, Inc. (component cULus) Figure 1. Integrated Burner Control Subpanel, dimensions in inches (mm). Models Available Single and dual fuel for the following modes of operation:...

 Open the catalog to page 4

All Cleaver-Brooks catalogs and technical brochures

  1. LCS150e.1

    2  Pages

  2. LCS250e.1

    2  Pages

  3. LevelMaster

    4  Pages

  4. Model 4

    4  Pages

  5. Model 5

    4  Pages

  6. Oil Pump Set

    12  Pages

  7. PCS140e.1

    2  Pages

  8. ProFire-D

    8  Pages

  9. ProFire-NTH

    4  Pages

  10. ProFire-S1

    4  Pages

  11. Stack Damper

    2  Pages

  12. LC ClearFire

    8  Pages

  13. Heat Recovery

    8  Pages

  14. SCR

    4  Pages

  15. FLX Flextube

    8  Pages

  16. ADAC

    2  Pages

  17. 4WI - CBLE

    8  Pages

  18. CBR

    4  Pages

  19. ICB

    8  Pages

  20. CBL

    4  Pages

  21. Ohio Special

    4  Pages

  22. CB Accu-Draft

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.