1. Catalogs
  2. Cleaver-Brooks
  3. HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers
video corpo

HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers
1 /8Pages

HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers

HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers
1 /8Pages

Catalog excerpts

HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers-1

HIGH EFFICIENCY, LOW EMISSIONS WET-BACK FIRETUBE BOILERS

 Open the catalog to page 1
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers-2

WHEN SPECIFYING, BUYING OR REPLACING YOUR NEXT BOILER remember the Cleaver-Brooks 4WG & ICB advantages: Four (4) Pass wet-back boilers ranging in size from 100 - 800 HP High and low pressure steam and hot water Highly engineered packages, matching burner with boiler to deliver: • Fuel economy • Compact footprint PPM NOx is only available on model 4WG The model ICB is available in 3 pass design if desired Optional upgrades such as the LevelMaster™ low water cutoff or Hawk™ Boiler Management control system, adding additional value to an already value rich offering. Single source, single responsibility...

 Open the catalog to page 2
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers-3

ENGINEERED BOILER OFFERINGS START • Highly efficient fuel burning packages with • Accurate fuel/air ratio control with 14 point adjustment cam(s), simple linkage assembly and Cleaver-Brooks Profire burner's unique rotary air • Low emission options ranging from 75, 30, 15 when applicable. • Easy access components with • Optimum safety with state of the art burner management and limiting control schemes. minimizing emissions requires excellent burner entire firing range. It is ICB™ line of firetube Rotary Damper Adjustable Cams packaged burners with and without flue maximums depending when burning...

 Open the catalog to page 3
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers-4

UNIQUE FEATURES This four pass wet-back firetube boiler is ruggedly constructed for hot water or low and high pressure steam applications. Ranging in size from 100-800 horsepower, this gas, #2 oil or combination fired product is a highly engineered and fully compatible boiler/burner package featuring excellent fuel to steam/water efficiency, space savings, low emissions, Excellent efficiency: Attaining high fuel to steam/water efficiencies, in excess of 80%, does not happen by chance. It requires exacting combustion and heat transfer design to assure optimum performance throughout the entire...

 Open the catalog to page 4
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers-5

MODEL ICB Wet-back features with Dry-Back Advantages This boiler model is truly unique! Its designed to incorporate the key features and benefits of both a wetback and dry-back boiler while delivering exceptional value at a competitive price! The key is the revolutionary inter-cooled rear turnaround chamber coupled with the Profire packaged burner and larger furnace; optimizing radiant heat transfer, maintaining high efficiencies, lowering emissions, easing maintenance… all while conserving valuable floor space! Inter-cooled rear access way: Relatively cool 3rd pass gas passing across the Btu...

 Open the catalog to page 5
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers-6

Models 4WG & ICB The industry’s new standard for firetube boiler packages • Highly engineered packages matching burner & boiler for optimum performance • Provides application flexibility with multiple fuel firing Throughout our 80 year history, Cleaver-Brooks has been symbolized by the flame in hand representing the Greek • Size range from 100 – 800 horsepower god Prometheus who harnessed fire for the betterment of • Hot water, low or high pressure steam mankind. This symbol represents a tradition of service and • Lowest emissions to < 9 PPM NOx on natural gas and 70 PPM #2 oil* continual pursuit...

 Open the catalog to page 6
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers-7

Worldwide Sales, Parts and Service U.S.A. and anada C Repr esen at ve O f i t i fces = H eadquar s t er = Banch O fi r fce International Representatives • • • • • • • • • Argentina Australia Bahamas Bangladesh Barbados Belize Bermuda Bolivia Bulgaria • • • • • • • • Chile Colombia Costa Rica Dominican Republic Ecuador Egypt El Salvador England • • • • • • • • • Guam Guatemala Honduras Hong Kong Israel Jamaica Jordan Kuwait Mexico • • • • • • Nicaragua Oman Pakistan Panama Paraguay Peoples Republic of China • Peru • Philippines • • • • • • • • • Puerto Rico Qatar Saudi Arabia Singapore Taiwan...

 Open the catalog to page 7

All Cleaver-Brooks catalogs and technical brochures

  1. LCS150e.1

    2  Pages

  2. LCS250e.1

    2  Pages

  3. LevelMaster

    4  Pages

  4. Model 4

    4  Pages

  5. Model 5

    4  Pages

  6. Oil Pump Set

    12  Pages

  7. PCS140e.1

    2  Pages

  8. ProFire-D

    8  Pages

  9. ProFire-NTH

    4  Pages

  10. ProFire-S1

    4  Pages

  11. Stack Damper

    2  Pages

  12. LC ClearFire

    8  Pages

  13. Heat Recovery

    8  Pages

  14. SCR

    4  Pages

  15. FLX Flextube

    8  Pages

  16. ADAC

    2  Pages

  17. 4WI - CBLE

    8  Pages

  18. CBR

    4  Pages

  19. ICB

    8  Pages

  20. CBL

    4  Pages

  21. Ohio Special

    4  Pages

  22. CB Accu-Draft

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.