HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers
8Pages

{{requestButtons}}

Catalog excerpts

HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers - 1

HIGH EFFICIENCY, LOW EMISSIONS WET-BACK FIRETUBE BOILERS

Open the catalog to page 1
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers - 2

WHEN SPECIFYING, BUYING OR REPLACING YOUR NEXT BOILER remember the Cleaver-Brooks 4WG & ICB advantages: Four (4) Pass wet-back boilers ranging in size from 100 - 800 HP High and low pressure steam and hot water Highly engineered packages, matching burner with boiler to deliver: • Fuel economy • Compact footprint PPM NOx is only available on model 4WG The model ICB is available in 3 pass design if desired Optional upgrades such as the LevelMaster™ low water cutoff or Hawk™ Boiler Management control system, adding additional value to an already value rich offering. Single source, single...

Open the catalog to page 2
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers - 3

ENGINEERED BOILER OFFERINGS START • Highly efficient fuel burning packages with • Accurate fuel/air ratio control with 14 point adjustment cam(s), simple linkage assembly and Cleaver-Brooks Profire burner's unique rotary air • Low emission options ranging from 75, 30, 15 when applicable. • Easy access components with • Optimum safety with state of the art burner management and limiting control schemes. minimizing emissions requires excellent burner entire firing range. It is ICB™ line of firetube Rotary Damper Adjustable Cams packaged burners with and without flue maximums depending when...

Open the catalog to page 3
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers - 4

UNIQUE FEATURES This four pass wet-back firetube boiler is ruggedly constructed for hot water or low and high pressure steam applications. Ranging in size from 100-800 horsepower, this gas, #2 oil or combination fired product is a highly engineered and fully compatible boiler/burner package featuring excellent fuel to steam/water efficiency, space savings, low emissions, Excellent efficiency: Attaining high fuel to steam/water efficiencies, in excess of 80%, does not happen by chance. It requires exacting combustion and heat transfer design to assure optimum performance throughout the...

Open the catalog to page 4
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers - 5

MODEL ICB Wet-back features with Dry-Back Advantages This boiler model is truly unique! Its designed to incorporate the key features and benefits of both a wetback and dry-back boiler while delivering exceptional value at a competitive price! The key is the revolutionary inter-cooled rear turnaround chamber coupled with the Profire packaged burner and larger furnace; optimizing radiant heat transfer, maintaining high efficiencies, lowering emissions, easing maintenance… all while conserving valuable floor space! Inter-cooled rear access way: Relatively cool 3rd pass gas passing across the...

Open the catalog to page 5
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers - 6

Models 4WG & ICB The industry’s new standard for firetube boiler packages • Highly engineered packages matching burner & boiler for optimum performance • Provides application flexibility with multiple fuel firing Throughout our 80 year history, Cleaver-Brooks has been symbolized by the flame in hand representing the Greek • Size range from 100 – 800 horsepower god Prometheus who harnessed fire for the betterment of • Hot water, low or high pressure steam mankind. This symbol represents a tradition of service and • Lowest emissions to < 9 PPM NOx on natural gas and 70 PPM #2 oil* continual...

Open the catalog to page 6
HIGH EFFICIENCY, LOW EMISSIONS Wet-Back Firetube Boilers - 7

Worldwide Sales, Parts and Service U.S.A. and anada C Repr esen at ve O f i t i fces = H eadquar s t er = Banch O fi r fce International Representatives • • • • • • • • • Argentina Australia Bahamas Bangladesh Barbados Belize Bermuda Bolivia Bulgaria • • • • • • • • Chile Colombia Costa Rica Dominican Republic Ecuador Egypt El Salvador England • • • • • • • • • Guam Guatemala Honduras Hong Kong Israel Jamaica Jordan Kuwait Mexico • • • • • • Nicaragua Oman Pakistan Panama Paraguay Peoples Republic of China • Peru • Philippines • • • • • • • • • Puerto Rico Qatar Saudi Arabia Singapore...

Open the catalog to page 7

All Cleaver-Brooks catalogs and technical brochures

  1. LCS150e.1

    2 Pages

  2. LCS250e.1

    2 Pages

  3. LevelMaster

    4 Pages

  4. Model 4

    4 Pages

  5. Model 5

    4 Pages

  6. Oil Pump Set

    12 Pages

  7. PCS140e.1

    2 Pages

  8. ProFire-D

    8 Pages

  9. ProFire-NTH

    4 Pages

  10. ProFire-S1

    4 Pages

  11. Stack Damper

    2 Pages

  12. LC ClearFire

    8 Pages

  13. SCR

    4 Pages

  14. FLX Flextube

    8 Pages

  15. ADAC

    2 Pages

  16. 4WI - CBLE

    8 Pages

  17. CBR

    4 Pages

  18. ICB

    8 Pages

  19. CBL

    4 Pages

  20. Ohio Special

    4 Pages