Model HAWK ADAC Advanced Deaerator Control HAWK ADAC ADVANCED DEAERATOR CONTROL The CB ADAC Advanced Deaerator Control provides a PLC based control system for a deaerator, surge tank, two tank deaerator-and-surge, or Duo-tank installations. The system is capable of controlling operation of boiler feed and/or transfer pumps, maintaining tank levels, monitoring and responding to system demands, and recording/annunciating alarm conditions. The ADAC can run as a stand-alone system or connect to a CB-HAWK Master Panel or customer building automation system for monitoring purposes. FEATURES AND BENEFITS Standard Features: • Integration of various deaerator and surge tank devices in a common control system • Touch screen graphical Human Machine Interface (HMI) • Deaerator and surge tank water level modulating controls • Basic Chemical feed pump control • Boiler feed pump control - up to 6 pumps via variable speed drive, soft starters, combination starters, or contactors • Surge tank feed pump control (transfer pumps) - up to 3 pumps • Pump alternating, lead/lag, and automatic rotation • Serial, Ethernet, BAS, web server communications capability • Control of remote devices (valves, etc.) • Alarm/fault annunciation and history with audible alarm • Red/Yellow/Green stack light for visual status indication • Resettable Cumulative pump run time totals for maintenance purposes Optional Features: • 10” PanelView Plus in lieu of 7” (10” is standard on two tank systems) Section D05-1 Rev. 03-11

Open the catalog to page 1
HAWK ADAC ADVANCED DEAERATOR CONTROL - 2

Model HAWK ADAC Advanced Deaerator Control • Alarm bell, horn, or electric sounder • GEMS Mini Sure Site level indicator with 4-20 mA transmitter, DP Level transmitter or discrete level switches • Steam or water flow transmitters • Manual hard wired controls for any 4-20 mA controlled valve • Siemens motorized make-up valve • RSLinx OPC compliant remote monitoring software • Recirculation bypass (tank one only) • NEMA 4/12 entrance panel • NEMA 4x electrical panel PRODUCT OFFERING Standard Features, Single Tank System: • Compact Logix L32E processor • 7” color touch screen HMI • Stack light...

Open the catalog to page 2
HAWK ADAC ADVANCED DEAERATOR CONTROL - 3

Model HAWK ADAC Advanced Deaerator Control Standard Features, Duo Tank or DA-and-Surge System: • Compact Logix L32E processor • 10" color touch screen HMI • Stack light Programming and I/O cards for the following: • I/O for 1-6 boiler feed pumps and 1-3 transfer pumps using contactors, soft starters, or combination starters • Hard wired fixed location level inputs for HI and LO water alarms, and low water pump cutoff for 2 tanks • Audible alarm output • Stack light outputs • Recirc bypass output • Chemical feed relay • Boiler 1-6 ‘Feed Water Required’ inputs for hard piped one pump per...

Open the catalog to page 3
HAWK ADAC ADVANCED DEAERATOR CONTROL - 4

Model HAWK ADAC Advanced Deaerator Control SAMPLE SPECIFICATIONS CB ADAC ADVANCED DEAERATOR CONTROL PART 1 1.1 GENERAL GENERAL A. Each ADAC system shall be factory equipped with a pre-configured Programmable Controller and Human Machine Interface. B. System shall provide control logic for the following: 1. 1-6 feed pumps and 1-3 transfer pumps 2. Make up water level control for DA tank or DA and Surge 3. Low Water, Hi Water, and Aux Low Water alarms 4. Chemical feed control PART 2 2.1 PRODUCTS STANDARD SYSTEM AND OPTIONS A. Hardware Platform - Standard System 1. Compact Logix L32E...

Open the catalog to page 4
HAWK ADAC ADVANCED DEAERATOR CONTROL - 5

Model HAWK ADAC 2.2 Advanced Deaerator Control SENSORS AND TRANSMITTERS A. Tank level indication 1. Standard a. DA tank - GEMS Mini Sure Site with transmitter b. Surge tank - GEMS Mini Sure Site with transmitter 2. Optional a. DA tank - Differential pressure level transmitter b. Surge tank - Differential pressure level transmitter B. Tank Pressure and Temperature (see table) Tank Pressure/Temperature Transmitters Standard Optional DA tank pressure transmitter E&H Rosemount-3051 DA pump discharge pressure transmitter E&H Rosemount-3051 Surge tank transfer pump pressure transmitter E&H...

Open the catalog to page 5
HAWK ADAC ADVANCED DEAERATOR CONTROL - 6

Model HAWK ADAC 2.5 Advanced Deaerator Control SOFTWARE DEVELOPMENT PLATFORM (software not required - for informational purposes only) A. RSLogix 5000 (controller logic programming) B. RSView ME (HMI programming) C. RSView32 / Factory Talk (control room display and data acquisition) D. RSLinx OEM version (OPC server - Building Automation System) 2.6 MAJOR FUNCTIONS THAT THE ADAC SYSTEM SHALL PROVIDE: (controller functions based on customer configuration and purchase of options) A. Feed water pump control 1. System will be able to support up to 6 pumps, selected using the HMI (no PC or...

Open the catalog to page 6
HAWK ADAC ADVANCED DEAERATOR CONTROL - 7

Model HAWK ADAC Advanced Deaerator Control 4. An optional Surge tank MUV biasing mode is available. A bias may be enabled (user defined) to force the primary MUV feeding the DA tank to close as level falls in the surge tank. The bias factor applied to the primary MUV position increases as the level in the surge tank gets lower. This prevents the surge tank from pumping down to low water cutout so it can continue to run while condensate is returned to it. You would then have the secondary valve plumbed to the DA from a separate source and add water to the DA to be heated, deaerated and sent...

Open the catalog to page 7
HAWK ADAC ADVANCED DEAERATOR CONTROL - 8

Model HAWK ADAC 2.7 Advanced Deaerator Control ADDITIONAL ADAC SYSTEM FUNCTIONS: A. A pressure sensor mounted in steam space monitors Deaerator pressure. B. A set of contacts on each pump’s overload relay provides indication of pump failure. If VSDs or soft starters are used, a fault contact is monitored by the PLC to indicate pump failure. C. A set of contacts on each pump starter indicates pump running. If VSDs or soft starters are used, a contact is monitored by the PLC to indicate run status. D. A selector switch is mounted at each pump starter to allow Hand- Off-Auto switching. ‘Hand’...

Open the catalog to page 8
HAWK ADAC ADVANCED DEAERATOR CONTROL - 9

Model HAWK ADAC Advanced Deaerator Control 2. Data can be transferred by Ethernet through a CB Master Panel to a customer BAS. If a Master Panel is unavailable, the protocol translator can be configured to communicate directly between the ADAC and the customer BAS. Section D05-9 Rev. 03-11

Open the catalog to page 9

All Cleaver-Brooks catalogs and technical brochures

  1. LCS150e.1

    2 Pages

  2. LCS250e.1

    2 Pages

  3. LevelMaster

    4 Pages

  4. Model 4

    4 Pages

  5. Model 5

    4 Pages

  6. Oil Pump Set

    12 Pages

  7. PCS140e.1

    2 Pages

  8. ProFire-D

    8 Pages

  9. ProFire-NTH

    4 Pages

  10. ProFire-S1

    4 Pages

  11. Stack Damper

    2 Pages

  12. LC ClearFire

    8 Pages

  13. SCR

    4 Pages

  14. FLX Flextube

    8 Pages

  15. ADAC

    2 Pages

  16. 4WI - CBLE

    8 Pages

  17. CBR

    4 Pages

  18. ICB

    8 Pages

  19. CBL

    4 Pages

  20. Ohio Special

    4 Pages