Overview
The document provides detailed information about Cleaver-Brooks' high-efficiency, low-emissions firetube boilers, specifically the Model 4WI and CBLE. These boilers are designed for steam and hot water applications ranging from 100 to 800 horsepower (HP). They are engineered to offer high efficiency, low emissions, and ease of maintenance, with options for both wet-back and dry-back configurations.
Model 4WI
The Model 4WI is a wet-back firetube boiler known for its reliability, compact footprint, and long life. It offers high efficiency with guaranteed performance and low emissions, achieving less than 7 ppm NOx on natural gas and less than 70 ppm NOx on #2 oil. The design includes a 4-pass configuration and features such as whisper-quiet operation and easy maintenance.
Model CBLE
The Model CBLE is a dry-back firetube boiler that shares design elements with the 4WI but includes an integral burner. It offers similar benefits, including high efficiency, low emissions, and flexibility for additional options. The CBLE is designed for long life and safety, with a focus on ease of maintenance and quiet operation.
Design and Technology
Both models incorporate advanced burner design and furnace geometry, utilizing Computational Fluid Dynamics (CFD) modeling for optimized heat transfer and efficiency. The boilers feature integrated controls, heat recovery systems, and options for low NOx emissions. The design prioritizes safety, with features like the LevelMaster™ water level control and AccuLink™ fuel/air control system.
Efficiency and Emissions
The boilers are engineered to achieve high fuel-to-steam/water efficiency, backed by a $10,000-per-point guarantee. Emissions are minimized through advanced burner design and flue gas recirculation (FGR), with options for ultra-low NOx emissions.
Life Cycle and Cost
Cleaver-Brooks boilers are designed for long life, with an average lifespan exceeding 25 years. They offer low life cycle costs due to their efficiency, ease of maintenance, and high residual value. The boilers are compact, saving space and reducing initial construction costs.
Additional Features
The boilers come with flexible options, including variable speed drives, modulating feedwater valves, and O2 trim systems. The Hawk 1000/4000 Boiler Management Control provides integrated management and communication capabilities.
Conclusion
Cleaver-Brooks' 4WI and CBLE boilers offer a comprehensive solution for efficient and environmentally friendly steam and hot water generation. With a focus on safety, reliability, and low emissions, these boilers are supported by a global network of service and parts providers.
See more

Catalog excerpts

4WI - CBLE-1

HIGH-EFFICIENCY, LOW-EMISSIONS 4WI - CBLE WET-BACK/DRY-BACK FIRETUBES Steam & Hot Water 100-800 HP

 Open the catalog to page 1
4WI - CBLE-2

Delivering high-efficiency, low-emissions control worldwide. Our Model 4WI wet-back firetube boiler not only offers high efficiency but low emissions with options for low NOx. The Model 4WI not only has a history of being reliable, but offers a smaller footprint, maximum safety, easy maintenance and long life. Engineered by Cleaver-Brooks to provide a low lifecycle cost, the 4WI is a great value for the investment. 100 – 800 HP 4-pass, wet-back configuration High efficiencies guaranteed at $10,000 per point! Low emissions to less than 7 ppm NOx, on natural gas and less than 70 ppm NOx on #2 oil*...

 Open the catalog to page 2
4WI - CBLE-3

Offering easy maintenance, saftey and flexibility. Exha Soluti Integr Contr Heat Recovery Our Model CBLE firetube boiler has the same design elements of the 4WI only in a dry-back configuration. With the same great offerings, the Model CBLE also comes with an integral burner. It’s a boiler package designed for long life, high fuel-to-steam/water efficiency, maximum safety, lowest emissions, quiet operation, ease of maintenance and the flexibility to add desired options to further enhance the package. 125 – 800 HP Dry-back configuration High efficiencies guaranteed at $10,000 per point! Low emissions...

 Open the catalog to page 3
4WI - CBLE-4

WET-BACK OR DRY-BACK CONFIGURATION The Cleaver-Brooks 4WI and CBLE line of firetube boilers are offered in either a 4-pass wet-back (4WI) or dry-back design (CBLE), both of which come with an integral burner. It’s a boiler package designed for long life, highest fuel-to-steam/water efficiency, maximum safety, lowest emissions, quiet operation, ease of maintenance and the flexibility to add desired options to further enhance the package. Burner Design and the Furnace Geometry Cleaver-Brooks team of highly qualified combustion and heat transfer engineers, using computational fluid dynamic modeling...

 Open the catalog to page 4
4WI - CBLE-5

Reliability & Long Life Highest Efficiency Design engineering and manufacturing excellence the primary reasons for the extended life of a Cleaver-Brooks firetube boiler. With over 100,000 units in the field, the average life exceeds 25 years with many C- B LevelMaster™ cases exceeding 50! Therefore, reliability should not be considered an intangible. Not when you consider a single downtime occurrence can result in a production loss that far exceeds the cost of the boiler. And no other boiler holds such a high resale value or is the most preferred rental boiler choice. Why? Because it’s the most...

 Open the catalog to page 5
4WI - CBLE-6

Low Life Cycle Cost The best way to evaluate the actual cost for a long-term asset is through the life cycle costing discipline. When evaluating the best and lowest overall cost boiler to choose, one should seriously consider the following criteria in addition to initial cost: What boiler gives me the longest life, reducing my replacement/renewal costs over the required life span of the asset? The average Cleaver-Brooks firetube boiler has a life expectancy of 25 years with hundreds of units still efficiently performing after 50 years! in the industry! Conservatively, this saves you thousands...

 Open the catalog to page 6
4WI - CBLE-7

When Specifying, Buying or Replacing Your Next Boiler Exha Soluti Integr Contr Heat Recovery Remember the Cleaver-Brooks 4WI & CBLE Advantages: • Highest efficiencies guaranteed at $10,000 per point • Lowest emissions to less than 7 ppm NOx on natural gas and less than 70 ppm NOx on #2 oil • Maximum safety • Ease of maintenance • Low NOx options (LE from 60 – 30, NT from 9 to less than 7 ppm) precisely matching your requirements • 4-pass Wet-Back or Dry-Back option • Space savings • Long life • Whisper-quiet operation • Flexible options • Lowest life cycle cost • ingle source, single responsibility...

 Open the catalog to page 7
4WI - CBLE-8

Total Integration goes far beyond boilers. For more than 80 years, Cleaver-Brooks has built a reputation for innovation in the boiler solutions industry. We remain committed to introducing technology and products that enable a more energy-efficient and environmentally friendly generation of steam and hot water. When you come to us for a boiler, you can know that each element is created to the highest standards, and all will work together seamlessly to give you a highly efficient and reliable solution for protecting your boiler system. To learn more, please call or visit us online. Packaged Boiler...

 Open the catalog to page 8

All Cleaver-Brooks catalogs and technical brochures

  1. LCS150e.1

    2  Pages

  2. LCS250e.1

    2  Pages

  3. LevelMaster

    4  Pages

  4. Model 4

    4  Pages

  5. Model 5

    4  Pages

  6. Oil Pump Set

    12  Pages

  7. PCS140e.1

    2  Pages

  8. ProFire-D

    8  Pages

  9. ProFire-NTH

    4  Pages

  10. ProFire-S1

    4  Pages

  11. Stack Damper

    2  Pages

  12. LC ClearFire

    8  Pages

  13. Heat Recovery

    8  Pages

  14. SCR

    4  Pages

  15. FLX Flextube

    8  Pages

  16. ADAC

    2  Pages

  17. CBR

    4  Pages

  18. ICB

    8  Pages

  19. CBL

    4  Pages

  20. Ohio Special

    4  Pages

  21. CB Accu-Draft

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.