Group: CleanAir Engineering
Catalog excerpts
Heated Methane / NonMethane / Total Hydrocarbon Analyzer (NMHC) Model-200 The VIG Industries, Inc. Model-200 is a microprocessor based, oven heated methane / nonmethane / total hydrocarbon gas analyzer designed for high accuracy, sensitivity and stability. The Model-200 uses two independent flame ionization detectors (FIDs), one to measure total hydrocarbons and the second coupled with a GC Column for the separation of the methane and nonmethane components. A sample is fed to the analyzer via an internal heated pump to the first FID for a real time total hydrocarbon reading. A portion of the sample is trapped and pushed through a column to separate the methane component and then to the second FID. Any remaining sample in the column is back flushed through the column to obtain the nonmethane component. All components that come in contact with the sample through analysis are maintained in a temperature-controlled oven to prevent condensation, and to provide repeatable, reliable performance in the analysis of a wide variety of hydrocarbon concentrations in gaseous mixtures or in ambient air. • Easy to use software • Automatic start-up/ignition • Heated sample pump heads • Two stage sample filter with exchangeable sintered stainless steel elements • PTFE isolated detectors (FIDs) • Automatic fuel shut-o system • Automatic flame-out indicators • Adjustable alarm and oven settings • Precision 1% of full scale • 4-20mA output - no extra charge • Zero and calibration solenoids with software • RS-232 interface • Internal combustion air supply Related Available Equipment • • • • • Zero air generator (Reduces bottles) Hydrogen generator (Reduces bottles) Heated sample lines and controllers Strip chart recorders and data loggers NEMA rated enclosures • Compliance Monitoring - U.S. E.P.A. Method 18 and Method 25A • Process Monitoring - Continuous monitoring and alarm or control of: process gas streams utilizing organic solvents, crude oil, and other chemicals containing hydrocarbons. • Efficiency Monitoring - Monitoring euent of volatile organic compound (VOC) reduction equipment for environmental compliance, eciency control of incinerators (Thermal or catalytic), scrubbers, carbon absorbers, and other abatement equipment, monitoring of catalytic converters, combustion and diesel engine eciency. • Safety Monitoring - Lower explosive limit (LEL) monitoring and/or control of ovens/dryers, fugitive emissions monitoring, personnel work area monitoring, leak detection of process equipment or solvent storage areas. • Stack Monitoring • Toll Free (800)862-7844 • Phone (714)632-8200 • Fax (714)632-8201 • http://www.vigindustries.com
Open the catalog to page 1Standard Specifications Measuring Method - 2 Oven Heated, Flame Ionization Detectors (FIDs) Separation Method - GC Column Measurement Range/Standard Ranges - (4 Ranges per amplifier, 2 amplifiers per analyzer, 1 amplifier for total and 1 amplifier for methane and nonmethane) •0-10, 0-100, 0-1000, 0-10000ppm (Lower detection limit 0.01 ppm) or •Other ranges available upon request Zero & Span Noise - Less than 0.2% of full scale Zero & Span Drift - +/- 1 % full scale per 24 hours Linearity- Within 1% of full scale through all ranges Repeatability - Within 1 % of full scale through all ranges...
Open the catalog to page 2All CleanAir Europe catalogs and technical brochures
-
Aeroqual Series 500
1 Pages
-
LDAR phx42
2 Pages
-
ETG MCA 100 SYN
2 Pages
-
MCA 100 Syn
1 Pages
-
ETG MCA 100 SYN P
2 Pages
-
ETG MCA 100 BIO P
2 Pages
-
ETG MCA 100 BIO
2 Pages
-
ETG 6500 SYN WM
2 Pages
-
ETG 6500 BIO WM
2 Pages
-
MET-80
2 Pages
-
ETG 6900 TDL NH3
1 Pages
-
ETG QE-PAS
2 Pages
-
ETG 4500 EIMS
3 Pages
-
ETG 6900 TDL HCl
1 Pages
-
ETG 6900 TDL
4 Pages
-
Jerome J405
2 Pages
-
Model 48C CO Analyzer
2 Pages
-
MAK10-Peltier
6 Pages
-
catalogue 2011
100 Pages
-
Model-20
2 Pages
-
Model-10/2
2 Pages
-
Model-20/2
2 Pages
-
Model-10
2 Pages