Heated Total Hydrocarbon Analyzer The VIG Industries, Inc. Model-20 is a microprocessor based, oven heated total hydrocarbon gas analyzer designed for high accuracy, sensitivity and stability. The Model- 20 uses a Name ionization detector (FID) for continuous measurement. All components that come in contact with the sample through analysis are maintained in a temperature- controlled oven to prevent condensation, and to provide repeatable, reliable performance in the analysis of a wide variety of hydrocarbon concentrations in gaseous mixtures or in •Automatic start-up / ignition •Heated sample pump head •Two stage sample filter with exchangeable sintered stainless steel elements • PTFE isolated detector (FID) •Automatic fuel shut off system •Automatic flame-out indicator •Adjustable alarm and oven settings •Automatic ranging • Precision 1 % of full scale • Fast response •Choice of Hydrogen or Hydrogen/Helium •Automatic calibration •Zero and calibration solenoids with •Second concentration level alarm •Internal combustion air supply •Purge and internal cleaning system • Dilution system •User selectable fuel (H2 or H2/He mixture) •Range recognition relays •Multi-point sequencer •Sample shut-off • Process Monitoring- Continuous monitoring and alarm or control of: process gas streams utilizing organic solvents, crude oil, and other chemicals containing hydrocarbons. •Efficiency Monitoring - Monitoring effluent of volatile organic compound (VOC) reduction equipment for environmental compliance, efficiency control of incinerators (thermal or catalytic), scrubbers, carbon absorbers, and other abatement equipment, monitoring of catalytic converters, combustion and diesel engine efficiency. •Safety Monitoring - Lower explosive limit (LEL) monitoring and/or control of ovens/dryers, fugitive emissions monitoring, personnel work area monitoring, leak detection of process equipment or solvent storage areas. • Stack Monitoring Related Available Equipment •Zero air generator (Reduces bottles) •Hydrogen generator (Reduces bottles) •Heated sample lines and controllers •Strip chart recorders and data loggers •NEMA rated enclosures 4051 E. La Palma #C Anaheim, CA 92807 • Toll Free (800)862-7844 • Phone (714)632-8200 • Fax (714)632-8201 • http://www.vigindustries.com

Open the catalog to page 1
Model-20 - 2

Standard Specifications Measuring Method - Oven Heated, Flame Ionization Detector (FID) Measurement Range/Standard Ranges - (4 Ranges per amplifier, one choice per analyzer) • 0-10, 0-100, 0-1000, 0-10000ppm (lower detection limit 0.01ppm) • 0-100, 0-1000, 0-10000, 0-100000ppm (lower detection limit 0.1ppm) Other ranges available upon request Zero & Span Noise - Less than 0.2% of full scale Zero & Span Drift - +/- 1% full scale per 24 hours Linearity - Within 1% of full scale through all ranges Repeatability - Within 1% of full scale through all ranges Stability - Within 1% of full scale...

Open the catalog to page 2

All CleanAir Europe catalogs and technical brochures

  1. LDAR phx42

    2 Pages

  2. MCA 100 Syn

    1 Pages

  3. MET-80

    2 Pages

  4. ETG QE-PAS

    2 Pages

  5. ETG 6900 TDL

    4 Pages

  6. Jerome J405

    2 Pages

  7. catalogue 2011

    100 Pages

  8. Model-10/2

    2 Pages

  9. Model-20/2

    2 Pages

  10. Model-10

    2 Pages

  11. Model-200

    2 Pages