Model-10
2Pages

{{requestButtons}}

Catalog excerpts

Model-10 - 1

The VIG Industries, Inc. Model-10 is a microprocessor based, spot heated total hydrocarbon gas analyzer designed for high accuracy, sensitivity and stability. The Model-10 uses a flame ionization detector (FID) for continuous measurement. The FID is spot heated to prevent condensation, and to provide repeatable, reliable performance in the analysis of a wide variety of hydrocarbon concentrations in gaseous mixtures or in ambient air. • Easy to use software • Automatic start-up/ignition • Two stage sample filter with exchangeable sintered stainless steel elements •PTFE isolated detector (FID) • Automatic fuel shut-o system • Automatic flame-out indicator • Adjustable alarm settings • Automatic ranging • Precision 1.5% of full scale • Fast response • 19" rack/bench mount • Choice of Hydrogen or Hydrogen/Helium fuel • Automatic calibration • Zero and calibration solenoids with software • RS-232 interface • Second concentration level alarm • Internal combustion air supply • Purge and internal cleaning system • Dilution system • User selectable fuel (H 2 or H 2 /H e mixture) • Range recognition relays • Multi-point sequencer • Sample shut-off • Compliance Monitoring • Process Monitoring - Continuous monitoring and alarm or control of: process gas streams utilizing organic solvents, crude oil, and other chemicals containing hydrocarbons. • Efficiency Monitoring - Monitoring euent of volatile organic compound (VOC) reduction equipment for environmental compliance, eciency control of incinerators (Thermal or catalytic), scrubbers, carbon absorbers, and other abatement equipment, monitoring of catalytic converters, combustion and diesel engine eciency. • Safety Monitoring - Lower explosive limit (LEL) monitoring and/or control of ovens/dryers, fugitive emissions monitoring, personnel work area monitoring, leak detection of process equipment or solvent storage areas. • Stack Monitoring Related Available Equipment • • • • • Zero air generator (Reduces bottles) Hydrogen generator (Reduces bottles) Heated sample lines and controllers Strip chart recorders and data loggers NEMA rated enclosures • Toll Free (800)862-7844 • Phone (714)632-8200 • Fax (714)632-8201 • http://www.vigindustries.com

Open the catalog to page 1
Model-10 - 2

Standard Specifications Measuring Method - Spot Heated, Flame Ionization Detector (FID) Measurement Range/Standard Ranges - (4 Ranges per analyzer) •0-10, 0-100, 0-1000, 0-10000ppm (Lower detection limit 0.01 ppm) or •Other ranges available upon request Zero & Span Noise - Less than 0.5% of full scale Zero & Span Drift - +/- 1.5% full scale per 24 hours Linearity- Within 1.5% of full scale through all ranges Repeatability - Within 1.5% of full scale through all ranges Stability - Within 1.5% of full scale through all ranges Oxygen Synergism - Within 1.5% of full scale within selected range...

Open the catalog to page 2

All CleanAir Europe catalogs and technical brochures

  1. LDAR phx42

    2 Pages

  2. MCA 100 Syn

    1 Pages

  3. MET-80

    2 Pages

  4. ETG QE-PAS

    2 Pages

  5. ETG 6900 TDL

    4 Pages

  6. Jerome J405

    2 Pages

  7. catalogue 2011

    100 Pages

  8. Model-20

    2 Pages

  9. Model-10/2

    2 Pages

  10. Model-20/2

    2 Pages

  11. Model-200

    2 Pages