MAK10-Peltier
6Pages

{{requestButtons}}

Catalog excerpts

MAK10-Peltier - 1

Compact Gas Conditioning MAK10-Peltier State 06 / 2017 I Subject to change ✓ High performance peltier-cooler with two long lasting peltier-elements ✓ Precise outlet dew point even at significant load variations ✓ Corrosion resistant PTFE / PVDF heat exchanger ✓ Very compact design ✓ Digital display for temperature, alarms, logbook, operating hours counter and service interval indication ✓ Modular upgradeable and application dependently configurable ✓ 1 - 2 gas paths ✓ Integrable filters, flow meters, flow alarms, liquid sensors, gas pumps, preseparators und acid dosing ✓ Wall mounting, 19“-rack, or mobile housing Application The compact gas conditioning systems series MAK10-Peltier are used for continuous extractive gas analysis. They serve primarily for exact constant lowering of the sample gas dew point and thus for drying of the humid sample gas flow. In this way water vapour cross sensitivities and volumetric errors are minimized and damages of the sensible analyzer are avoided. With optional components like condensate pumps, preseparators, filters, liquid sensors, flow meters and sample gas pumps devices of series MAK10-Peltier can be upgraded to complete compact quick and simple integrable conditioning systems. The flexible modular design guarantees an optimum adaption to every measuring task. Technology The precise temperature control with pulse width modulation in combination with the innovative corrosion resistant heat exchangers achieves low extremely constant dew points. Also load fluctuations and high thermal stress is compensated reliably. The hydrophobic corrosion resistant PTFE coating and the very short retention time in the heat exchanger ensure a lowest possible gas dissolution rate. Functions An electronic system controls dew point and cooling air temperature. Potential free alarm contacts allow remote monitoring of the device. Operating parameters are stored for diagnosis in a log. An operation hours counter controls the service intervals. Available housing versions are wall mounting housing, 19“-rack housing and very light-weight mobile versions with carrying handles. Branch Frankfurt AGT-PSG GmbH & Co. KG ^ +49 (0) 6171 - 9750 - 0 Branch Erkelenz AGT-PSG GmbH & Co. KG ^ +49 (0) 2431 - 9627 - 0

Open the catalog to page 1
MAK10-Peltier - 2

Technical Data Model 25°C de temperature ambiante dp = point de rosee d'entree State 06 / 2017 I Subject to change ■ Dosage acide incl. pompe a condensats ■ Station d'accueil ■ 19 "-rack Options ■ Pompe a condensats ■ Filtre en profondeur PTFE, longueur 65 mm ou 102 mm ■ Pompe a gaz echantillon N86 IP00 ou IP20 ■ Debitmetre pour max. 150 ou 250 ou 500 l / h ■ Debitmetre avec barriere lumineuse et electronique ■ Capteur de liquide interne ou externe incl. electroniquePre-separator incl. condensate pump En raison du grand nombre d'options, une grande variete de configurations individuelles du...

Open the catalog to page 2
MAK10-Peltier - 3

MAK10 Heat-Exchanger System State 06 / 2017 I Subject to change More efficiency, no energy losses, even at high ambient temperatures ✓ Coldness transfer through aluminium ✓ Good thermal conductance 204 W/m°K ✓ Double sided cold transfer with 2 peltier elements ✓ Extremely compact design ✓ Optimal shielding from the environment High and constant dryness rate even at extreme load variations ✓ PTFE-coated, hydrophobic surface ✓ Immediate formation of large condensate droplets ✓ Spiral performing condensate stream goes downwards ✓ Consistent use of gravity ✓ Discharge of condensate at the...

Open the catalog to page 3
MAK10-Peltier - 4

MAK10-Peltier Model Examples MAK10P-1 ✓ 1 echangeur de chaleur PTFE / PVDF ✓ 1 voie de gaz (2 x 175 l / h) ✓ 1 pompe a condensats ✓ 1 contact d'alarme MAK MAK10P-1 aves pre-separateur ✓ 1 echangeur de chaleur PTFE / PVDF ✓ 1 PTFE filtre en profondeur ✓ 1 pompe gaz echantillon ✓ 1 MAK contact d‘alarme s» MAK10P-2 avec station ✓ 1 double echangeur de chaleur PVDF ✓ 2 PTFE filtres en profondeur ✓ 2 capteurs liquide et electroniques ✓ 1 MAK- / 2 capteur de contact d'alarme State 06 / 2017 I Subject to change MAK10P-2 19“-rack version ✓ 2 echangeurs de chaleur PTFE / PVDF ✓ 1 PTFE filtre en...

Open the catalog to page 4
MAK10-Peltier - 5

State 06 / 2017 I Subject to change Configuration examples MAK10P-1 MAK10P-2 © Heat exchanger © Condensate pump ® Condensate pre-separator © PTFE depth filter © Sample gas pump © Flow meter © Electronic ® Liquid sensor ® Light barrier Branch Frankfurt AGT-PSG GmbH & Co. KG ^ +49 (0) 6171 - 9750 - 0 Branch Erkelenz AGT-PSG GmbH & Co. KG ^ +49 (0) 2431 - 9627 - 0

Open the catalog to page 5
MAK10-Peltier - 6

Integrated components / options Condensate pump Reliable continuous condensate removal Low rotation speed, long lasting pump tube Condensate pre-separator Separation of free condensate and solid particles Sample gas pre-cooling for inlet dew points >65°C State 06 / 2017  Subject to change PTFE depth filter Reliable filtration of solid particles Quick and simple filter change Flow meter Exact dosing, with fine adjustment needle valve Optional with light barrier Liquid sensor Protects against condensate break through Reliable detection of smallest amounts of liquid Control / alarm for liquid...

Open the catalog to page 6

All CleanAir Europe catalogs and technical brochures

  1. LDAR phx42

    2 Pages

  2. MCA 100 Syn

    1 Pages

  3. MET-80

    2 Pages

  4. ETG QE-PAS

    2 Pages

  5. ETG 6900 TDL

    4 Pages

  6. Jerome J405

    2 Pages

  7. catalogue 2011

    100 Pages

  8. Model-20

    2 Pages

  9. Model-10/2

    2 Pages

  10. Model-20/2

    2 Pages

  11. Model-10

    2 Pages

  12. Model-200

    2 Pages