ETG MCA 100 SYN
2Pages

{{requestButtons}}

Catalog excerpts

ETG MCA 100 SYN - 1

ETG MCA 100 SYN multicomponent gas analyzer for Syngas O2, CO2, CO, CH4, H2, CnHm MONITORING Suitable for applications: • Syngas Plants • Hythane Plants • Research Center • Syngas System Integrator The ETG MCA 100 SYN series of gas analyzers by ETG are the ideal solution for Syngas measurement applications because of their accuracy, stability, reliability, broad measurement range, and the variety of available form factors. Unlike other analyzers, ETG MCA 100 SYN P non-dispersive infrared (NDIR) gas analyzers measure multiple gases in the instrument in special wavelenght regions, interferences free from the other components. The TCD detector used for H2 analysis is automatically corrected via proprietary algorithm for possible interferences by other gases. ETG analyzers have the ability to measure CH4, CO2, CO, CnHm, H2 and O2 providing the optimal combination of gases for Syngas process optimization. The enhanced optics and electronics of our NDIR analyzers have virtually eliminated zero drift after the initial warm up period. The temperature and pressure compensation eliminates the major causes of span drift in the instruments. USER INTERFACE OVERVIEW • Cross sensitivity compensation • Arm processor • Touch Screen monitor • Ethernet and USB Remoting • Low cost of ownership ETG Risorse e Tecnologia S.r.l. — Via Baione 2/K 10034 Chivasso (IT) — Tel: +39 011 192.708.90 — email: info@etgrisorse.com https

Open the catalog to page 1
ETG MCA 100 SYN - 2

SPECIFICATIONS • Sample conditioning system (optional) • Automatic Autozero free selectable • Totally developed in Italy • NDIR (for CO2 CO and CH4) & TCD (for H2) technology • N2 and Heat value calculated by proprietary algorithm (standard) • TCD for H2 Response Time Response time are specified at a sample flow rate of 1 liter per minute through the MCA 100 sample cell Data Refresh Rate Warm-up Time From to 10 to 20 minutes (depending on external temperature) Operating Temperature & Humidity Operating Altitude Zero & Span user selectable External Electrical Supply Power consumption Output...

Open the catalog to page 2

All CleanAir Europe catalogs and technical brochures

  1. LDAR phx42

    2 Pages

  2. MCA 100 Syn

    1 Pages

  3. MET-80

    2 Pages

  4. ETG QE-PAS

    2 Pages

  5. ETG 6900 TDL

    4 Pages

  6. Jerome J405

    2 Pages

  7. catalogue 2011

    100 Pages

  8. Model-20

    2 Pages

  9. Model-10/2

    2 Pages

  10. Model-20/2

    2 Pages

  11. Model-10

    2 Pages

  12. Model-200

    2 Pages