Group: CleanAir Engineering
Catalog excerpts
ETG MCA 100 BIO P multicomponent gas analyzer for Biogas MONITORING MONITORING Suitable for applications: • • • • • BIOGAS PLANTS BIOMETHANE UPGRADING RESEARCH CENTER WATER TREATMENT PLANT BIOGAS SYSTEM INTEGRATOR The MCA 100 Bio series of gas analyzers by ETG are the ideal solution for Biogas measurement and industrial combustion applications because of their accuracy, stability, reliability, broad measurement range, and the variety of available form factors. Unlike other analyzers, ETG MCA 100 non-dispersive infrared (NDIR) gas analyzers measure multiple gases in an instrument with a single optical path platform. Single-gas analyzers are inadequate when using methane as a biofuel, because the gas often contains large amounts of CO2 as a contaminant. ETG analyzers have the ability to measure CO2, H2S and O2 in addition to methane, providing the optimal combination of gases analysis for Biogas/Biomethane process. The enhanced optics and electronics of our NDIR analyzers have virtually eliminated zero drift after the initial warm up period. The temperature and pressure compensation eliminates the major causes of span drift in the instruments. monitorINTERFACE USER • Touch Screen monitor • Ethernet, Wi-Fi and USB Remoting • Low cost of ownership • Portable version with battery ETG Risorse e Tecnologia S.r.l. — Via Baione 2/K 10034 Chivasso (IT) — Tel: +39 011 192.708.90 — email: info@etgrisorse.com htt
Open the catalog to page 1SPECIFICATIONS • NDIR (for CO2 and CH4) & ECD (for H2S, O2) technology • Impact resistant housing • N2 and calorific value calculated by proprietary algorithm (standard) • Totally developed in Italy • Dust filter front panel • Internal sample pump Response Time Response time are specified at a sample flow rate of 1 liter per minute through the MCA 100 sample cell Data Refresh Rate Warm-up Time 30 seconds ready, 3 minutes useable, 30 minutes full performance Operating Temperature Operating Humidity Operating Altitude Case protections Touch Screen 5.7” Resistive Type Zero & Span user...
Open the catalog to page 2All CleanAir Europe catalogs and technical brochures
-
Aeroqual Series 500
1 Pages
-
LDAR phx42
2 Pages
-
ETG MCA 100 SYN
2 Pages
-
MCA 100 Syn
1 Pages
-
ETG MCA 100 SYN P
2 Pages
-
ETG MCA 100 BIO
2 Pages
-
ETG 6500 SYN WM
2 Pages
-
ETG 6500 BIO WM
2 Pages
-
MET-80
2 Pages
-
ETG 6900 TDL NH3
1 Pages
-
ETG QE-PAS
2 Pages
-
ETG 4500 EIMS
3 Pages
-
ETG 6900 TDL HCl
1 Pages
-
ETG 6900 TDL
4 Pages
-
Jerome J405
2 Pages
-
Model 48C CO Analyzer
2 Pages
-
MAK10-Peltier
6 Pages
-
catalogue 2011
100 Pages
-
Model-20
2 Pages
-
Model-10/2
2 Pages
-
Model-20/2
2 Pages
-
Model-10
2 Pages
-
Model-200
2 Pages