ETG 6500 SYN WM
2Pages

{{requestButtons}}

Catalog excerpts

ETG 6500 SYN WM - 1

ETG 6500 SYN WM advanced multicomponent gas analyzer for Syngas O2, CO2, CO, CH4, H2, CnHm MONITORING MONITORING Suitble for applications: • Syngas Plants • Hythane Plants • Research Center • Syngas System Integrator The ETG 6500 SYN series of gas analyzers by ETG are the ideal solution for Syngas measurement applications because of their accuracy, stability, reliability, broad measurement range, and the variety of available form factors. Unlike other analyzers, ETG 6500 SYN non-dispersive infrared (NDIR) gas analyzers measure multiple gases in the instrument in special wavelenght regions, interferences free from the other components. The TCD detector used for H2 analysis is automatically corrected via proprietary algorithm for possible interferences by other gases. ETG analyzers have the ability to measure CH4, CO2, CO, CnHm, H2 and O2 providing the optimal combination of gases for Syngas process optimization. The enhanced optics and electronics of our NDIR analyzers have virtually eliminated zero drift after the initial warm up period. The temperature and pressure compensation eliminates the major causes of span drift in the instruments. USER INTERFACE OVERVIEW • Arm processor • Touch Screen monitor • Ethernet, Wi-Fi and USB Remoting • Low cost of ownership • Modbus, Pro ibus, Ethernet (optional) and others ETG Risorse e Tecnologia S.r.l. — Via Baione 2/K 10034 Chivasso (IT) — Tel: +39 011 192.708.90 — email: info@etgrisorse.com https

Open the catalog to page 1
ETG 6500 SYN WM - 2

SPECIFICATIONS • NDIR (for CO2 CO and CH4) & TCD (for H2) technology • N2 and Heat value calculate by proprietary algorithm (standard) • TCD for H2 • CnHm measured by NDIR detector (optional) • Sample conditioning system (optional) • Automatic Autozero free selectable • Continous Calculation Calorific Value • Totally developed in Italy Response Time Response time are specified at a sample flow rate of 1 liter per minute through the MCA 100 sample cell Data Refresh Rate Warm-up Time 30 seconds ready, 3 minutes useable, 30 minutes full performance Operating Temperature Operating Humidity...

Open the catalog to page 2

All CleanAir Europe catalogs and technical brochures

  1. LDAR phx42

    2 Pages

  2. MCA 100 Syn

    1 Pages

  3. MET-80

    2 Pages

  4. ETG QE-PAS

    2 Pages

  5. ETG 6900 TDL

    4 Pages

  6. Jerome J405

    2 Pages

  7. catalogue 2011

    100 Pages

  8. Model-20

    2 Pages

  9. Model-10/2

    2 Pages

  10. Model-20/2

    2 Pages

  11. Model-10

    2 Pages

  12. Model-200

    2 Pages