Air Pollution Sampling Equipment For Environmental Professionals Worldwide

Open the catalog to page 1
catalogue 2011 - 2

TERMS & CONDITIONS Prices and Terms Our prices are subject to change without notice. The price in effect when we receive your order will apply. All prices are F.O.B. Palatine, Illinois. We will be pleased to furnish quotations by phone, fax, e-mail or mail. Terms of payment are Net 30 days with established credit, or by Visa/Master Card at time of order. Invoices over 30 days past due are subject to a 1.5% finance charge per month. Confirming Orders Please make sure that all confirming orders are clearly marked to avoid duplicate orders. Shipments and Delivery Unless otherwise instructed,...

Open the catalog to page 2
catalogue 2011 - 3

ENGINEERING • Calibration Services • technical Services • Engineering and Custom Fabrication Services • Repair Services

Open the catalog to page 3
catalogue 2011 - 4

Air Pollution Sampling Equipment Table of Contents Source Sampling Equipment Source Sampling equipment Continued

Open the catalog to page 4
catalogue 2011 - 5

Air Pollution Sampling Equipment Table of Contents CEM EQUIPMENT Parts & ACCESSORIES

Open the catalog to page 5
catalogue 2011 - 6

All Clean Air Engineering sampling trains contain components that are compatible with and comparable to systems currently used in the industry today. Source Sampling Equipment Let the account teams at Clean Air Engineering Express help you assemble these sampling train components required to perform EPA particulate and gaseous sampling. We have all the equipment you need, when you need it.

Open the catalog to page 6
catalogue 2011 - 7

Source Sampling EQUIPMENT Source Sampling equipment Continued Source Sampling Equipment Source Sampling Equipment

Open the catalog to page 7
catalogue 2011 - 8

Air Velocity Kit Method 2 Method 2 Method 2 Each kit includes: Stainless steel standard pitot tube Inclined-vertical manometer Two (2) 9’ lengths of rubber tubing Air velocity calculator slide rule Magnetic mounting clips Additional gauge oil Steel carrying case. Pitot Assemblies Pitot assemblies include: • “S” type pitot • Grounded Stack Thermocouple • Pitot and Thermocouple are shrouded into a 1” stainless steel sheath Part Number Part Number 03 - Length (0306 = 6 Ft. Pitot Assembly) Geometric pitot calibration is included. *Custom order len9ths always available Wind tunnel...

Open the catalog to page 8
catalogue 2011 - 9

Solid Thermocouples Type “K” thermocouple, grounded, stainless steel sheath, 1/8”O. D. with standard K-Type male plug. Custom Thermocouple available in as few as three days. Specification: • Sheath- Stainless steel • Style- Quick Disconnect Standard Male Plug • Calibration- Type K • Diameter- 0.125 (1/8)” • Junction- Grounded • Continuous Temperature Limit-1600°F Part Number Thermocouples Accessories Clean Air Express has a huge selection of Thermocouples and Thermocouples accessories. Custom Lengths are available.

Open the catalog to page 9
catalogue 2011 - 10

SOURCE SAMPLING EQUIPMENTFlue Gas Analyzer Method 3 Method 3 Method 3 Clean Air Express Flue gas Analyzer rapidly analyzes gas mixtures, specifically to determine carbon dioxide, oxygen and carbon monoxide. Burrell Allied Cabinet Model Gas Analyzer: Graduated 100-ml gas measuring burette, one contact and two auto bubbler absorption pipettes for determining carbon dioxide, oxygen and carbon monoxide levels. Burrell Industro model B gas Analysis System: Graduated 0-21% gas measuring burette, one contact and two auto bubbler absorption pipettes for determining carbon dioxide, oxygen and...

Open the catalog to page 10
catalogue 2011 - 11

Tedlar® Bags Unlike other sample bag materials, Tedlar® film resists gas permeation - both into and out of the bag, assuring sample integrity for all applications. Tedlar® is rated for continuous use from -98 to 225 F. This wide range of operation allows for use in very cold or very hot environments including stacks, vents, and flues. Tedlar® film is inert to a wide range of chemicals. Tedlar® Bags are referenced for many EPA methods, including Methods 3, 18 and 40. Optional Twist Valve w/ Septum *Note: We recommend shipping filled Tedlar® bags in a rigid carton to prevent damage/discharge...

Open the catalog to page 11
catalogue 2011 - 12

Source Sampling EQUIPMENT Method 5 Sampling Train Part Number The Clean Air Method 5 Train is the benchmark of the industry. It is suited to perform isokinetic particulate testing Referencing Federal EPA 40 CFR 60, Appendix A, Method 5 -“Determination of Particulate Emissions From Stationary Sources.” Other pollutants can be collected in the impinger portion of the system providing the proper reagent is utilized. A Method 5 Train is the basic equipment for several EPA Reference Methods. Ask your Clean Air Express customer Service Representative for details on the accessories needed to...

Open the catalog to page 12
catalogue 2011 - 13

Source Sampling EQUIPMENT Method 5 Sampling Train Diagram Method 5 Sampling Train Monorail Support Port Seal Adapter #0140 M5 Probe, Liner and Nozzle M5 Sample Oven #0032 Stack Wall 4 Impinger Compartment #0033 Standard Impinger Assembly (Greenburg Smith) #05755 Modified Impinger Assembly #05750 Method 5 Umbilical Isokinetic Control Console #0028 250

Open the catalog to page 13
catalogue 2011 - 14

SOURCE SAMPLING EQUIPMENTCateco Method 5 Sampling Train The Method 5 Cateco Sampling Train is similar to the Method 5 train except that it replaces the Modular Sample Unit with a more versatile Cateco Heated Filter Unit. Separating the probe and heated filter from the glassware makes this train ideal for testing vertical and hard to access locations. The Clean Air Cateco Method 5 Train is suited to perform isokinetic particulate testing Referencing Federal EPA 40 CFR 60, Appendix A, Method 5 -“Determination of Particulate Emissions From Stationary Sources.” Other pollutants can be collected...

Open the catalog to page 14
catalogue 2011 - 15

Source Sampling EQUIPMENT Cateco Method 5 Sampling Train Diagram Cateco Method 5 Sampling Train Method 5 Method 5 Cateco Heated Filter Oven #0035 Socket to Hose Barb Connector 28/12 #0508 Port Seal Adapter #0140 M5 Probe, Liner and Nozzle Cateco Umbilical Extension Stack Wall 4 Impinger Compartment #0033 Standard Impinger Assembly (Greenburg Smith) #05755 Modified Impinger Assembly #05750 Isokinetic Control Console #0028

Open the catalog to page 15
catalogue 2011 - 16

Source Sampling EQUIPMENT Method 5 CE Sampling Train 0100-5-220VCE Part Number The Clean Air Method 5 Train is suited to perform isokinetic particulate testing referencing US EPA 40 CFR 60, European prEN 13284-1. It is also compatible with Standard ISO 9096 for sampling particulates emissions from chimneys or smoke stacks. Condensable pollutants can be collected in the impingers per EPA Method 202. Part Number 0028220MCE 0032220CE 0033 05003B 0034 036050QCCE 0106BS220CE 0140 0400NS 0156 0621.26 • • • • • Item Isokinetic Control Console with Pump – CE Marked Sample Oven Compartment – CE...

Open the catalog to page 16

All CleanAir Europe catalogs and technical brochures

  1. LDAR phx42

    2 Pages

  2. MCA 100 Syn

    1 Pages

  3. MET-80

    2 Pages

  4. ETG QE-PAS

    2 Pages

  5. ETG 6900 TDL

    4 Pages

  6. Jerome J405

    2 Pages

  7. Model-20

    2 Pages

  8. Model-10/2

    2 Pages

  9. Model-20/2

    2 Pages

  10. Model-10

    2 Pages

  11. Model-200

    2 Pages