MODEL E804-DZ FLUID HEATER 800 BHP
2Pages

{{requestButtons}}

Catalog excerpts

MODEL E804-DZ FLUID HEATER 800 BHP - 1

CLAYTON FLUID HEATERS OFFER: • COMPACT SIZE Clayton steam generators will normally fit in any available area while also reducing construction costs on new building installations. . FUEL EFFICIENT High efficiency which is inherent with the clayton design translates into lower operating costs and improved overall system operation . RESPONSIVE Very rapid response to changing steam loads. Clayton steam generator will automatically modulate to match your steam load profile while maintaining system steam pressure . SAFE Our once through design eliminates the possibility of a steam or water side explosion. The Clayton steam generator is simply the safest steam boiler on the market. . LESS WATER WASTE Clayton’s design concentrates TDS blow down significantly which reduces wasted fuel, water and chemical costs. . FAST START Full steam pressure and output in minutes from a cold startup saves fuel and labor cost over conventional designs. Eliminates wasted fuel from idling. . AUTOMATIC Operation is automatically controlled and the Clayton steam generator can be started from a single switch or remotely using an automatic start option. . LOW WEIGHT The relatively light weight means that all sizes of Clayton steam generators can be easily moved and installed even in areas with limited structural support. • RELIABLE Reliability of the Clayton steam generator is field proven and unsurpassed. This results in greatly reduced maintenance and attendance. • HIGH QUALITY STEAM Steam Quality in excess of 99.5% dry is assured at all times. This is the highest steam quality of any competitive design. Less water and impurities further increase your energy efficiency.

Open the catalog to page 1
MODEL E804-DZ FLUID HEATER 800 BHP - 2

MODEL E804 BOILER HORSEPOWER HEAT INPUT, BTU/hr Oil Gas NET HEAT OUTPUT, BTU/hr EQUIVALENT OUTPUT (from and at 212°F feedwater and 0 PSIG steam) DESIGN PRESSURE (see note 1) STEAM OPERATING PRESSURE (determined by design pressure) OIL CONSUMPTION at maximum steam output (see note 2) GAS CONSUMPTION at maximum steam output (see note 3) BURNER CONTROLS modulating EFFICIENCY oil-fired efficiency % gas-fired efficiency % ELECTRIC MOTORS, HP (see note 4) design pressure 15-300 psig design pressure 301-500 psig ELECTRIC FLA, based on 460 V (see note 5) design pressure 15-300 psig design...

Open the catalog to page 2

All CLAYTON INDUSTRIES catalogs and technical brochures

  1. PLC Control

    2 Pages

  2. Hotwell

    2 Pages

Archived catalogs