CLARK SOLUTIONS PXR Series Temperature & Process Controllers Fuji Electric PID Controllers with Fuzzy Control of Self-Tuning TThe new PXR series controllers are the newest additions to Fuji Electric’s trusted line of temperature and process controllers. They are now packed with features and options acome in several sizes – 1/32 DIN, 1/16DIN, 1/8 DIN and 1/4 DIN. These controllers have all the standard features that you expect from Fuji Electric’s superior controllers, and more. In addition to auto-tuning and fuzzy control, they now come with selftuning — an innovation in the control field. It automatically retunes the controller under certain conditions, without the need to revert to auto-tuning. The standard 8-segment ramp/soak feature has been expanded to include two patterns that can be linked to create a 16-step profile. The PXR accepts temperature and process inputs and offers a choice of three kinds of outputs to meet a wide variety of needs in the process industries. Low-cost options include dual outputs, programmable alarms, remote setpoint, RS485 communications, analog retransmission, digital input, timer function, heater burnout alarm and 24V AC/DC supply voltage. One of the most impressive features is the large LED display. The faceplate, designed for NEMA 4X (IP66 equivalent), is watertight and corrosion-resistant. The easy-to-use 3-button keypad allows for programming similar to the popular PXW controller. The screw-terminal on the back further reduces the cost by eliminating the need for sockets. The PXR3 can be DINrail mounted with the optional adapter. Remote monitoring of up to 31 controllers at a time is possible with the RS485 option that uses the industry-standard ModbusTM protocol. The communications option comes with our free Windows®-based software, PXR-LITETM. The software allows you to program the controller from the PC and view real-time data and trend graph while logging the data into a text file. A powerful tool for the OEM customer is the Program Loader option with Windows®-based software. Programs for different applications can be saved to and from the controller. Power supply voltage: 100 (-15%) to 240V (+10%) AC, 50/60Hz; 24V (±10%) AC/DC Power consumption: PXR3: 6VA (100 VAC), 8VA (220V, 24V). PXR4: 8VA (100V), 10VA (220V), 12VA (24V). PXR5, 9: 10VA(100V), 12VA (220V, 24V) Reference junction compensation: accuracy ±1°C at 23°C Input Input signal Thermocouple: J, K, R, B, S, T, E, N, PL2. RTD: Pt100. Voltage, current. For 1 to 5V/4 to 20 mA DC, 0 to 5V/0 to 20 mA DC, use 250 ohm shunt resister included Input filter: 0 to 900.0 sec set in 0.5 sec steps Burnout: For thermocouple or RTD input, control output direction (upper or lower) is selectable Control Function Control action On/Off; PID control (with auto-tuning, self-tuning); Fuzzy Control(with auto-tuning) Proportional band (P): 0 to 999.9% of measuring range set in 0.1% steps Integral time: (l) 0 to 3200 sec set in 1 sec steps Differential time: (D) 0 to 999.9 sec set in 1 sec steps Proportional cycle: 1 to 150 sec set in1 sec steps Hysteresis width: 0 to 50% of measuring range; For on/off action only Input sampling cycle: 0.5 sec Control Output 1 (select one) Relay contact: PXR4, 5, 9: SPDT, 220 V AC/30 V DC, 3A (resistive load). PXR3: SPST contact, 220 V AC/30 V DC, 3A(resistive load) SSR: PXR4, 5, 9: ON–17 to 25 V DC; OFF–0.5 V DC or less. PXR3: 12 to 16 V DC. Max. current: 20mA or less 4 to 20 mA DC: PXR4, 5, 9: Allowable load resistance 600 ohms or less. PXR3: 100 to 500 ohms Control Output 2 (Heating/Cooling Control) (select one) Relay contact: SPST, 220 V AC/30 V DC, 3A (resistive load) SSR: PXR4, 5, 9: ON–17 to 25 V DC; OFF–0.5 V DC or less. PXR3: 12 to 16 V DC. Max. current: 20mA or less 4 to 20 mA DC: PXR4, 5, 9: Allowable load resistance 600 ohms or less. PXR3: 100 to 500 ohms Operation and Display Section Parameter setting method: Digital setting by 3 keys; Key lock function provided Display unit: Process value/set value displayed individually 4 digits, 7-segment LED Status display LED: Control output, process alarm output, heater burnout alarm output Indication accuracy (at 23°C): Thermocouple: ± (0.5% of measuring range)± 1 digit ±1°C. For thermocouple R at 0 to 500°C: ± (1% of measuring range) ±1 digit ±1°C. For thermocouple B at 0 to 400°C: ± (5% of measuring range) ±1 digit ±1°C. RTD, voltage/current: ±(0.5% of measuring range) ±1 digit • Advanced control functions PID Plus Self Tuning; PID Plus Fuzzy Control; Autotuning • NEMA 4X faceplate with large LED display 4-digit, red and green display; Waterproof faceplate conforms to NEMA-4X/IP66 • Multiple inputs Choose between thermocouple/ RTD and 4-20mA/0-5V inputs • Single or dual control outputs Relay, SSR driver or 4-20mA • Ramp/soak function Up to 16 ramp/soak segments or two 8-segment patterns,a standard feature • Programmable alarms option 2 programmable SPST relays with On/Off delay function • Remote setpoint option Change setpoint with a 1-5V signal • Analog retransmission option 4-20mA retransmission of PV, SV, MV, DV • Digital input option Change between 2 setpoints; Change between ramp/soak and standby; Start/reset the ramp/soak; Start/stop the auto tuning; Cancel the alarm latch; Start the incorporated timer • Timer function On-delay or off-delay timer activated with digital input; Up to 2 timer outputs can be obtained • Heater burnout alarm option If heater burns out, alarm goes off • Communications option RS485 (ModbusTM protocol) interface permits remote monitoring of up to 31 units from a PC. Comes with free Windows®-based software, PXR-LITETM • Warranty Manufactured in a ISO 9001 facility and backed by a 3-year warranty Clark Solutions 10 Bren
Open the catalog to page 1Program Loader Interface Alarm (option) Alarm type: Absolute alarm, deviation alarm, zone alarm with upper and lower limits for each; hold function available;alarm latch function provided Alarm ON-delay: Delay setting 0 to 9999 sec set in 1 sec steps Process alarm output: Relay contact: SPST, 220 V AC/30 V dC, 1A (resistive load); Max. 2 points (PXR3), max. 3 points (PXR4,5, 9) Heater burnout option: (not available on PXR3) Alarm setting range: 1 to 50A Available only when control output is relay or SSR drive. Heater burnout alarm: output Relay contact: SPST, 220 V AC/30 V DC, 1A (resistive load);...
Open the catalog to page 22 Pages
5 Pages
1 Page
2 Pages
1 Page
2 Pages
1 Page
3 Pages
35 Pages