jerguson Mag-gage brochure
12Pages

{{requestButtons}}

Catalog excerpts

jerguson Mag-gage brochure - 1

Magnetic Liquid Level Indication Products Magnicator II

Open the catalog to page 1
jerguson Mag-gage brochure - 2

Magnetic Liquid Level Indication Products Magnetic Field Density Diagramof Magnicator II Float Reliability is in the physics.A uniquely strong north magnetic field activates flags,switches and transmitters with a certainty not found elsewhere because only the Magnicator II has a magnet arrangement this powerful,and this focused. The Jerguson Magnicator II float has the strongest magnetic field of any magnetic level indicator. Its patented design (U.S.Patent 5,743,137) uses two 360κ annular Alnico 8 ring magnets with opposing north poles. If you are looking for reliable performance from a...

Open the catalog to page 2
jerguson Mag-gage brochure - 3

Magnetic Flux Density Plot of Magnicator II Float Opposing magnetic poles project concentrated flux lines away from the outside diameter of the magnets.This forced deflection creates a stronger field than any other float magnet arrangement,greater than 90 Gauss at the centerline of the indicator flags.Physics has guaranteedthat the Magnicator float has the strongest magneticfield...which translates to the most reliable instrument. > Typical floats from other manufacturers employ a circular array of Alnico 5 Bar Magnets.Other brands use a single ring magnet.Neither can produce as intense a...

Open the catalog to page 3
jerguson Mag-gage brochure - 4

Your demanding application deserves a gage withthe guts to stick it out for a long,long time.In addition to complying with ASME B31.1 for power piping and ASME B31.3 for process piping,all Magnicator > Magnicator Float II Magnetic Level Gages incorporateadditional design and construction benefits you will not find on any comparable product: > Other ManufacturerΒs Float Most other magnetic level gages are offered as Sch 10,with an upgrade to Sch 40 available. Since most plant piping specifications prohibit Sch 10 pipe,this can be misleading.The difference between Sch 10 and Sch 40 is...

Open the catalog to page 4
jerguson Mag-gage brochure - 6

NightStar LED base illuminator for the Magnicator > II >

Open the catalog to page 6
jerguson Mag-gage brochure - 7

Specification Overview FM & CSA Approval to: Class I,Div.I,Grps.B,C,& DClass II,Div.II,Grps.E,F,& G Օ Power Supply: 120 or 240 VAC Power Consumption: < 750 mA @ 120 VAC< 375 mA @ 240 VAC Օ Max.Remote Distance from Power Supply to Light Strip = ~80 feet (24.3m) Electrical Connection:3/4" FNPT Օ Ambient Temperature: -40F (-40ںC) to 170F (77ںC) Process Temperature: Up to 450պF (232C) 450ںF (232C) to 600ںF (316C)with air purge kit on indicator ڕ Protection Methods: Explosion-proof power supply NightStar Indicators can be field-upgradedon any Jerguson magnetic gage,or other manufacturers gage,by...

Open the catalog to page 7
jerguson Mag-gage brochure - 9

.001" resolution continuous outputՕ FM & CSA - Class 1,Div.I,Grps.B,C,& D; Class 1,Div.II,Grps.E,F,& G ATEX EEx ia IIB + H2 T4 Օ NEMA 4X design Adjustable zero and span Օ LCD display and window cover are standard Communication Protocols > Cutawayview 4-20 mA loop-powered transmitterwith Hart > ծ protocol (standard) Fieldbus Foundation > ٕ 4-20 mA loop-powered transmitter 1/2" (Std),1/4" (Optional) resolution Օ UL & C-UL Class 1,Div.I,Grps.B,C,& DClass 2,Grps.E,F,& G NEMA 4X design Օ Field Adjustable Span > No cams or springsՕ Highly vibration-resistant UL approved for hazardous...

Open the catalog to page 9
jerguson Mag-gage brochure - 10

Consult our Specification Guidefor complete model numbers and configuration options. Designed to meet needs of offshore industry,chemical wash-down,and severe environmentsՕ Flag indicators are sealed in glass tube; 100% fused glass end seals No gaskets: > Օ Up to 900 psi (62 bar) per code requirements Indicator range 2" above and below steam and water connections canՒt leak or fog > Ε LED indicators have no moving parts 10 year nominal life on LED Օ Field-upgradeable; easy clamp-on installation Approved for use in general purpose areasՕ Red and green standard; other colors available 120/240...

Open the catalog to page 10
jerguson Mag-gage brochure - 11

Hot or Cold Insulation > Hot Insulation550˚F (287˚C) to 1000˚F (537˚C) Jacket covers entire gage and includes drawcords at each end for closure.Provided with openings for gage process connections, indicator and switches or transmitters. PTFE coated & impregnated fiberglass Օ 1" thickness to 550˚F (287˚C) 2" thickness to 800ՋF (426ڋC) ڕ 3" thickness to 1000˚F (537˚C) Stainless steel grommets Օ Polypropylene / fiberglass drawcord at ends Mini Magnicator > Economical magnetic gage features single bar magnet floatՕ Pressures to 400 psi (27 bar) Temperatures to 500ՋF (260ڋC) ڕ Specific gravity...

Open the catalog to page 11