Product catalog summary
Overview: The document provides detailed information about the Magnicator® II, a magnetic liquid level indication product by Jerguson, a part of The Clark-Reliance Corporation. It highlights the product's superior magnetic field strength, robust construction, and various features that enhance reliability and performance in industrial applications.
Specifications: The Magnicator II features a patented float design with two 360º annular Alnico 8 ring magnets, creating a strong and focused magnetic field. This design ensures reliable activation of flags, switches, and transmitters. The product complies with ASME B31.1 and B31.3 standards, with standard Schedule 40 chamber construction, and options for Sch 80 and Sch 160 for higher pressures.
Procedures: The Magnicator II operates by connecting to a process vessel, with a sealed float that rises and falls with liquid levels. The indicator flags rotate in response to the float's magnetic field, providing a clear visual indication of liquid levels.
Norms and Standards: The product adheres to ASME standards for power and process piping. It also features robust construction with full penetration autogenous welds for durability and reliability.
Recommendations: Jerguson recommends using flag indicators for most applications due to their reliability and resistance to shock and vibration. The NightStar LED illuminators are suggested for enhanced visibility in low-light conditions.
Additional Features: The document describes the integration of guided wave radar (GWR) for independent liquid level measurement, unaffected by changes in product density. It also details various switches and transmitters, including magnetostrictive and reed switch options, for enhanced functionality.
Options and Accessories: The document lists several options, including hermetically-sealed flag indicators, LevelStar LED indicators, and insulation options for extreme temperatures. It also mentions the availability of combination sight glass/magnetic gages and high-pressure column options.
Conclusion: The Magnicator II is presented as a reliable and robust solution for magnetic liquid level indication, with advanced features and compliance with industry standards, making it suitable for demanding industrial applications.
See more

Catalog excerpts

jerguson Mag-gage brochure-1

Magnetic Liquid Level Indication Products Magnicator II

 Open the catalog to page 1
jerguson Mag-gage brochure-2

Magnetic Liquid Level Indication Products Magnetic Field Density Diagramof Magnicator II Float Reliability is in the physics.A uniquely strong north magnetic field activates flags,switches and transmitters with a certainty not found elsewhere because only the Magnicator II has a magnet arrangement this powerful,and this focused. The Jerguson Magnicator II float has the strongest magnetic field of any magnetic level indicator. Its patented design (U.S.Patent 5,743,137) uses two 360κ annular Alnico 8 ring magnets with opposing north poles. If you are looking for reliable performance from a magnetic...

 Open the catalog to page 2
jerguson Mag-gage brochure-3

Magnetic Flux Density Plot of Magnicator II Float Opposing magnetic poles project concentrated flux lines away from the outside diameter of the magnets.This forced deflection creates a stronger field than any other float magnet arrangement,greater than 90 Gauss at the centerline of the indicator flags.Physics has guaranteedthat the Magnicator float has the strongest magneticfield...which translates to the most reliable instrument. > Typical floats from other manufacturers employ a circular array of Alnico 5 Bar Magnets.Other brands use a single ring magnet.Neither can produce as intense a magnetic...

 Open the catalog to page 3
jerguson Mag-gage brochure-4

Your demanding application deserves a gage withthe guts to stick it out for a long,long time.In addition to complying with ASME B31.1 for power piping and ASME B31.3 for process piping,all Magnicator > Magnicator Float II Magnetic Level Gages incorporateadditional design and construction benefits you will not find on any comparable product: > Other ManufacturerΒs Float Most other magnetic level gages are offered as Sch 10,with an upgrade to Sch 40 available. Since most plant piping specifications prohibit Sch 10 pipe,this can be misleading.The difference between Sch 10 and Sch 40 is substantial,with...

 Open the catalog to page 4
jerguson Mag-gage brochure-6

NightStar LED base illuminator for the Magnicator > II >

 Open the catalog to page 6
jerguson Mag-gage brochure-7

Specification Overview FM & CSA Approval to: Class I,Div.I,Grps.B,C,& DClass II,Div.II,Grps.E,F,& G Օ Power Supply: 120 or 240 VAC Power Consumption: < 750 mA @ 120 VAC< 375 mA @ 240 VAC Օ Max.Remote Distance from Power Supply to Light Strip = ~80 feet (24.3m) Electrical Connection:3/4" FNPT Օ Ambient Temperature: -40F (-40ںC) to 170F (77ںC) Process Temperature: Up to 450պF (232C) 450ںF (232C) to 600ںF (316C)with air purge kit on indicator ڕ Protection Methods: Explosion-proof power supply NightStar Indicators can be field-upgradedon any Jerguson magnetic gage,or other manufacturers gage,by replacing...

 Open the catalog to page 7
jerguson Mag-gage brochure-9

.001" resolution continuous outputՕ FM & CSA - Class 1,Div.I,Grps.B,C,& D; Class 1,Div.II,Grps.E,F,& G ATEX EEx ia IIB + H2 T4 Օ NEMA 4X design Adjustable zero and span Օ LCD display and window cover are standard Communication Protocols > Cutawayview 4-20 mA loop-powered transmitterwith Hart > ծ protocol (standard) Fieldbus Foundation > ٕ 4-20 mA loop-powered transmitter 1/2" (Std),1/4" (Optional) resolution Օ UL & C-UL Class 1,Div.I,Grps.B,C,& DClass 2,Grps.E,F,& G NEMA 4X design Օ Field Adjustable Span > No cams or springsՕ Highly vibration-resistant UL approved for hazardous locationsClass...

 Open the catalog to page 9
jerguson Mag-gage brochure-10

Consult our Specification Guidefor complete model numbers and configuration options. Designed to meet needs of offshore industry,chemical wash-down,and severe environmentsՕ Flag indicators are sealed in glass tube; 100% fused glass end seals No gaskets: > Օ Up to 900 psi (62 bar) per code requirements Indicator range 2" above and below steam and water connections canՒt leak or fog > Ε LED indicators have no moving parts 10 year nominal life on LED Օ Field-upgradeable; easy clamp-on installation Approved for use in general purpose areasՕ Red and green standard; other colors available 120/240 VAC...

 Open the catalog to page 10
jerguson Mag-gage brochure-11

Hot or Cold Insulation > Hot Insulation550˚F (287˚C) to 1000˚F (537˚C) Jacket covers entire gage and includes drawcords at each end for closure.Provided with openings for gage process connections, indicator and switches or transmitters. PTFE coated & impregnated fiberglass Օ 1" thickness to 550˚F (287˚C) 2" thickness to 800ՋF (426ڋC) ڕ 3" thickness to 1000˚F (537˚C) Stainless steel grommets Օ Polypropylene / fiberglass drawcord at ends Mini Magnicator > Economical magnetic gage features single bar magnet floatՕ Pressures to 400 psi (27 bar) Temperatures to 500ՋF (260ڋC) ڕ Specific gravity 0.7...