5E-C5808/C5808J Automatic Calorimeter

5E-C5808/C5808J Automatic Calorimeter

5E-C5808/C5808J Automatic Calorimeter

Product catalog summary
Overview: The document provides detailed specifications and configurations for the 5E-C5808 and 5E-C5808J automatic calorimeters, which are used to determine the calorific value of various combustibles. These devices are crucial for industries such as power plants, coal mines, and chemical industries.
Standard and Optional Configurations: Both models come with a main analyzer, standard CV bomb, computer, crucibles, ignition paper, benzoic acid, O-ring kit, and tool kit. Optional configurations include lens paper, pellet press, and a halogen-resistant oxygen vessel.
Features: The 5E-C5808J model features patented laser ignition technology, allowing for faster and easier sample preparation. Both models offer automatic oxygen vessel lifting, charging, and venting, intelligent temperature control, and compact design.
Technical Parameters: The calorimeters support automatic oxygen charging with a power requirement of 220V/50Hz and an air pressure of 2.8MPa-3.0MPa. The precision for 1g benzoic acid is 0.05% RSD, with a measuring range up to 50000J and a temperature resolution of 0.0001°C.
Specifications: The models conform to various international standards such as ASTM D240, ASTM D5865, and ISO 1928. The analysis time per sample is 8 minutes, with different methods offering varying times. The devices are benchtop or vertical in structure, with automatic or manual bomb vessel lifting.
Performance: The 5E-C5500 model exceeds ASTM precision requirements with a relative standard deviation of less than 0.05% RSD, surpassing the standard of 0.17% RSD.
See more

Catalog excerpts

5E-C5808/C5808J Automatic Calorimeter-1

Automatic Calorimeter Standard Configuration Main analyzer Standard CV bomb -1 Unit Computer Crucibles Ignition Paper Benzoic Acid O-ring kit Tool kit Optional Configuration Lens paper Pellet press Halogen Resistant Oxygen Vessel Automatic Calorimeter Standard Configuration Main analyzer Standard CV bomb -1 Unit Computer Crucibles Ignition Wire Benzoic Acid O-ring kit Tool kit Optional Configuration Lens paper Pellet press Halogen Resistant Oxygen Vessel Patented Laser Ignition Design Define the New Generation of Calorimeter * Available in C5808J Application 5E-C5808/5E-C5808J is CKIC new generation calorimeter which is used to determine the calorific value of solid and liquid combustibles including oil, coal, coke, foodstuffs and biomass products. The calorific value is a crucial characteristic for each substance, also the key point to calculate the price of coal, so it will directly affect the economic benefits of the customers. This technique is widely applied in power plants, coal mines, metallurgy, chemical industry, commercial inspection, scientific research, etc.

 Open the catalog to page 1
5E-C5808/C5808J Automatic Calorimeter-2

Features 1. Patented laser ignition technology (available in C5808J model) allowing easier and faster sample preparation, no ignition wire or cotton thread is needed 2. 8min fast analysis for one sample 3. Automatic oxygen vessel lifting 4. Automatic oxygen charging and venting 5. Intelligent temperature control of the jacket and the water tank, the water constant temperature stability of the jacket reaches to 0.02℃ 6. Small space occupied with compact design 7. Intelligent diagnosis and safety protection function Laser Beam Automatic Oxygen Charger Application Support the use of 5E Series Calorimeter,...

 Open the catalog to page 2
5E-C5808/C5808J Automatic Calorimeter-3

Test Data Calibrate Mass, g Temperature Rise as-determined Heat Capacity Remark: ASTM-D5865, the precision of ten acceptable calibration test runs shall have a relative standard deviation (RSD) no greater than 0.17% and CKIC’s specification is less than 0.05%RSD. Conclusion: 5E-C5500 Automatic Calorimeter exceeds the ASTM precision requirement. Specification Model Precision (1g Benzoic Acid) Temp. Resolution Measuring Range Control Ability Up to 50000J 2 Units / 1 PC available Dynamic method:10mins, Classical method:15mins Dynamic method: 11mins Classical method: 16mins Analysis Time per Sample...