Integrated Unit for Water Control WXU Series INTEGRATED UNIT FOR WATER CONTROL Space-saving pipeless Space-saving pipeless s 80% less footprint (2 fluid control type) Significant reduction of installation space due to fewer ports and utilization
Open the catalog to page 1A new era of water control A rich variation of water control equipment has all-in-one space-saving 80% less footprint by pipeless Compact Integrated Unit for Water Control Reduction of individual piping Reducing air leakage Reducing design arrangement man hours System image 1 fluid control type Supply unit Cooling portion 2 fluid control type MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN Cooling portion Return unit
Open the catalog to page 21 fluid ons specifications Cooling water supply and return is available with one unit. one n d A Valve can be equipped to both the return side and the supply side. By adopting a cock type valve, it can be opened and closed with one action and visual confirmation is easy. By making the in-block and valve housing lightweight it is easy to handle. 1 fluid specifications Cooling water supply and return is available with one unit. In the supply side, a needle and valve can be mounted, and individual control in each system (on/off) is possible. Easy adjustment flow rate with needle. 2 fluid...
Open the catalog to page 3WXU-H Series Port size: Rc3/8, Rc1/2, Rc1 Flow rate range: 0.5~32L/min Cooling portion Cooling portion be done in 1unit. Individual control is possible in each circuit. Working pressure MPa Proof pressure (water pressure) MPa Fluid temperature ºC Ambient temperature ºC Atmosphere Flow rate adjustment range % Station no. Mounting orientation Sealant IN/OUT port Port size Branch port Water, hot water 0~0.7 1.4 1~70 5~50 Place free of corrosive and explosive gases 0~100 (With water) 2-10 stations Free Fluoro rubber Rc1 Rc3/8 or Rc1/2 adjustment in the return side valve. Flow characteristics...
Open the catalog to page 4WXU-H Series How to order In-block position Left Right W Both sides Port size (branch port) Rc3/8 Rc1/2 (Not available when "T" water temperature measuring function is used.) D Flow rate range Flow sensor output A Station no. B In-block position C Port size (branch port) D Flow rate range Flow sensor output : 6stations : Left : Rc1/2 : 1.5~12L/min : NPN transistor 2 outputs (a contact point) function NPN transistor 2 outputs (a contact point) NPN transistor 2 outputs (b contact point) PNP transistor 2 outputs (a contact point) PNP transistor 2 outputs (b contact point) Both sides
Open the catalog to page 5WXU-H Series Internal structure and parts list Stainless steel casting Stainless steel Adjusting knob Flow sensor [WFK3000 series] Fluoro rubber
Open the catalog to page 6WXU-H Series Dimensions
Open the catalog to page 7Cooling portion Working pressure MPa Proof pressure (water pressure) MPa Fluid temperature ºC Ambient temperature ºC Atmosphere Cooling portion Flow rate adjustment range can be done in 1unit. Individual control is possible in each circuit. Water, hot water 0~0.4 (Note) 1.0 1~70 5~50 Place free of corrosive and explosive gases 0~100 (Water) Station no. Mounting orientation Sealant IN/OUT port Port size Branch port 2-10 stations Free Fluoro rubber Rc3/4 or Rc1/2 Rc3/8 or Rc1/2 Note: Please contact us when using it at higher than the usage pressure. Flow characteristics Water supply and...
Open the catalog to page 8Flow sensor output Descriptions A Left Right Both sides Port size (IN/OUT port) Valve actuation None Port size (branch port) Rc3/8 Rc1/2 (Not available when "T" water temperature measuring function is used.) F Flow rate range : 6stations : Left Port size (IN/OUT port) : Rc1 Valve actuation classification : Port size (branch port) : Rc1/2 Flow rate range : 1.5~12L/min Flow sensor output : NPN transistor 2 outputs (a contact point) A Station no. B In-block position In-block position DC0~10V NPN transistor 2 outputs (a contact point) NPN transistor 2 outputs (b contact point) PNP transistor 2...
Open the catalog to page 9Internal structure and parts list station Stainless steel Needle block Stainless steel Needle stopper Stainless steel Cold forging carbon steel Stainless steel Valving element Flow sensor [WFK3000 series] Stainless steel casting
Open the catalog to page 10Series Dimensions
Open the catalog to page 11Integrated Unit for Water Control Cooling portion Cooling portion (Return unit) as water and air). It is suitable for circuits that have water cooling and air purge. Individual control is possible in each circuit. (Used in 2 units) WXUWater, hot water, air 0~0.4 (Note) 1.0 1~70 5~50 Place free of corrosive and explosive gases 15~100 (With water) 2~6stations Free Fluoro rubber Rc1 Rc1/2 Rc3/8 or Rc1/2 Working pressure MPa Proof pressure (water pressure) MPa Fluid temperature ºC Ambient temperature ºC Atmosphere Flow rate adjustment range % Station no. Mounting orientation Sealant Fluid 1...
Open the catalog to page 12WXU-D Series If the entire 1 station assembly equipment configuration is the same, you can order the entire unit through symbol selection. If you form a unit with different equipment configurations mixed with the 1 station assembly , please specify the configuration in the "manifold specification sheet" (page 18). drainage classification <Example of model number> Water supply and drainage classification 2 fluid control type NC (normal close) type NC (normal close) type
Open the catalog to page 13Internal structure and parts list station Stainless steel casting Flow sensor [WFK3000 series] Needle stopper Stainless steel Cold forging carbon steel Stainless steel Stainless steel Stainless steel
Open the catalog to page 14Series Dimensions
Open the catalog to page 15Installed equipment specifications Valve portion specifications Flow sensor wiring method • The cable is a 4 wire cabtyre and uses a cable core of 0.2 mm2 • Sensor type voltage output specifications: -AO, -A2, -A3 • Sensor type current output specifications: -A1 Connect to the DC power supply plus [+] : DC12~24V±10% 1 Connect to the DC power supply minus [-] : DC 0V : Output voltage is proportional to : Please do not connect this to • • Connect to the DC power supply plus [+] : DC12~24V±10% • • • Connect to the 4-20mA input device • • Connect to the DC power supply minus [-] : DC 0V If you...
Open the catalog to page 16All CKD catalogs and technical brochures
-
【NEW】ABP2-HP1・AT2 Series Catalog
16 Pages
-
FP Series Precautions
7 Pages
-
FP Series Introduction
10 Pages
-
FCM Series Variation list
1 Pages
-
【NEW】WFK2 Series Catalog
24 Pages
-
【NEW】WFK2 Series Precautions
6 Pages
-
MN4GA / 4GB
140 Pages
-
4GD1 to 3R, 4GE1 to 3R
261 Pages
-
MV3QR
16 Pages
-
4F ** 0EX series
28 Pages
-
Pilot operated 5-port valve
74 Pages
-
MV3QRA1/MV3QRB1 Series
20 Pages
-
PV5G/PV5/GMF/PV5S-0
76 Pages
-
4G unit valve
4 Pages
-
SCP*3 Series
60 Pages
-
SCS2 series
56 Pages
-
Rodless cylinder SRL3
89 Pages
-
Linear slide cylinder LCG
58 Pages
-
Linear slide cylinder LCM
52 Pages
-
Linear slide cylinder LCX
64 Pages
-
Guided cylinder STM
24 Pages
-
Cartridge cylinder CAT
6 Pages
-
Compact cylinder SSD
221 Pages
-
Compact cylinder SSD2
278 Pages
-
Guided compact cylinder SSG
16 Pages
-
Medium bore size cylinder SCS
46 Pages
-
Medium bore size cylinder SCA2
161 Pages
-
Tie rod cylinder SCG
87 Pages
-
Medium bore size cylinder CMK2
107 Pages
-
Round shaped cylinder SCM
116 Pages
-
Medium bore size cylinder CMA2
20 Pages
-
Pencil shaped cylinder SCP*3
60 Pages
-
LMD series
15 Pages
-
KBZ series
64 Pages
-
AGD21R-A series
4 Pages
-
AX6000M
24 Pages
-
SCS-G Series
2 Pages
-
CMK2 SR
7 Pages
-
CMK2 Series Double acting
7 Pages
-
SSD-F/SSD-KF Series
1 Pages
-
CMK2-T Series
1 Pages
-
SCPS2-V Series
4 Pages
-
SCPD2-*C Series
1 Pages
-
SCPD2-K Series
3 Pages
-
SCPS2-MSeries
4 Pages
-
SCPD2-D/SCPD2-DT Series
3 Pages
-
SCPD2-F Series
2 Pages
-
SCPD2 Serie
3 Pages
-
SCPD2 Series
2 Pages
-
SCPS Series
1 Pages
-
SCM Series ø 20 to ø 63
2 Pages
-
SCM Series
2 Pages
-
GHV series
4 Pages
-
High purity gas systems
2 Pages
-
Component for chemicals
2 Pages
-
Labor-Saving products
8 Pages
-
General purpose valve
1 Pages
-
Pneumatic valves
8 Pages
-
Pneumatic cylinders
12 Pages