1. Catalogs
  2. CKD
  3. Tie rod cylinder SCG

Tie rod cylinder SCG

Tie rod cylinder SCG
1 / 87 PagesView full catalog

Tie rod cylinder SCG

Product catalog summary
Overview: The document introduces the eco-friendly SCG Series air cylinders, designed to eliminate toxic substances and prevent environmental contamination. These cylinders feature a compact design with ports and needles on the same plane for easier installation and adjustment.
Specifications: The SCG Series includes various types such as standard, position locking, low speed, low friction, double rod, non-rotating, rubber scraper, coolant proof, and spatter adherence prevention types. Bore sizes range from 32 to 100 mm, and the cylinders comply with RoHS Directives, ensuring no harmful substances like lead or hexavalent chrome are used.
Design Features: The cylinders have a uniform white exterior and a compact switch design that saves space. The T switch is smaller than conventional switches, eliminating protrusion and allowing easy installation with a switch bracket. The cylinders are up to 40 mm shorter than conventional models.
Installation & Adjustment: Detailed instructions are provided for installing flow control valves and adjusting switches, emphasizing the importance of using the correct torque and positioning for optimal performance.
Safety Precautions: Users are advised to read safety precautions before use. Key warnings include ensuring the cylinder load factor is 50% or less, avoiding synchronous operation of multiple cylinders, and not using quick exhaust valves with position locking cylinders.
Performance Considerations: The document outlines the kinetic energy absorption capabilities of rubber and air cushions, advising on the appropriate use of shock absorbers if kinetic energy exceeds specified values. It also highlights the importance of using clean air and avoiding lubrication to maintain cylinder performance.
Model Variations: The SCG Series offers a wide range of model variations to suit different applications, with options for customized piston rod end forms and various mounting styles.
Switch Specifications: The document outlines specifications for various switch models, including T1/T2Y/T3Y/T2YD switches, featuring a 1 color/2 color indicator and strong magnetic field proof capabilities. Power voltage ranges from 85 to 265 VAC, with load voltages and currents specified for different configurations.
Model Descriptions and Applications: The SCG-M Series is highlighted, with descriptions of different mounting styles such as axial foot type, rod end flange type, and clevis bracket type. The document provides a detailed guide on how to order, including model numbers, bore sizes, port thread types, and cushion types.
Installation and Maintenance: Detailed instructions are provided on installation methods for different mounting styles, including foot, flange, eye, and clevis brackets. Information on repair parts and maintenance, specifying materials used for various components, is also included.
Dimensions and Weight: Dimensions for basic types and configurations with bellows are provided, along with weight specifications for different bore sizes and mounting styles. Notes on dimensions for rubber cushion types and guidelines for ordering mounting brackets are included.
Additional Notes: The document advises consulting with CKD for specific working conditions and custom configurations, with notes on custom orders, environmental conditions, and specific installation requirements.
SCG-G4 Series Overview: The document provides detailed specifications and dimensions for the SCG-G4 Series, a type of double-acting cylinder designed to prevent spatter adherence. It includes information on internal structure, parts list, materials, and mounting styles.
SCG-G4 Specifications: The SCG-G4 Series features a variety of bore sizes ranging from 32mm to 100mm. Key components include rod nuts, piston rods, seals, bushings, and gaskets, primarily made from steel, nitrile rubber, and aluminum alloys. Different treatments like nickel plating and zinc chromate plating are specified for durability.
SCG-G4 Dimensions: Detailed dimensions are provided for various bore sizes, including measurements for mounting brackets and accessories. Dimensions for rubber cushion types are noted to be slightly longer than air cushion types.
SCG-G4 Mounting Styles: Several mounting styles are outlined, including LB, FA/FB, CA/CB, and TA/TB/TC, with materials such as steel and cast iron used for brackets.
SCG-G4 Accessories: Accessories like rod eyes, clevis brackets, and trunnion brackets are detailed with specific dimensions and weights. Notes on included components like pins and washers are provided.
SCG-G4 Notes: The document advises consulting with CKD for environment-compatible T-type switches and provides additional references for accessory dimensions on specific pages.
See more

Catalog excerpts

Tie rod cylinder SCG-1

guided cylinder Conventional switch Compact switch New easy-to-use SCG Series ( 32 to 100) air cylinders - Remove toxic substances and protect the environment by preventing contamination Port and needle on same plane Air supply/exhaust port and cushion needle installation on same side. Cylinder installation/ adjustment, etc. are easier. A T switch smaller than the conventional switch is used. This eliminates switch protrusion in installation, saving space. Switches are installed easily and smoothly with our original switch bracket. Fix with screws alone Installation is completed by tightening screws after adjusting switches. The mechanism sandwiches the tie rod, making the switch position adjustable without supporting the switch. Powerful fixing The T switch in the rail is finely adjustable. Easy switch install Standard magnets Ecological product Harmful substances such as lead and hexavalent chrome that adversely affect the global environment are not used in the cylinder and cylinder switch. This product complies with the RoHS Directives in effect in the EU. (Lead-free solder and lead wires) Switches can be installed on all products. Less installation space is required because the cylinder is up to 40 mm shorter than the conventional cylinder. Products match a variety of equipment with a uniform white exterior. SCG Series Products Model variation Bore size Standard type Position locking type Same dimensions for rubber scraper type (G), coolant proof type (G1, G2) and spatter adherence prevention type (G4) The dimensions of the rubber scraper and spatter adherence prevention are the same as the standard type, facilitating installation. Low friction type Double rod type Non-rotating type Tie rod cylinder Standard type Rubber scraper type Coolant proof type Spatter adherence type

 Open the catalog to page 1
Tie rod cylinder SCG-2

Series variation SCG Series Series variation Double acting low speed type Double acting low friction type Double acting double rod type Double acting non-rotating type Double acting powerful scraper type Double acting coolant proof type SCG-G4 Double acting spatter adhesion prevention type Trunnion type No. 2 bracket Clevis bracket Piston rod material stainless steel Copper and PTFE free Consult with CKD. Consult with CKD. Double acting position locking type Double acting single rod type Tie rod cylinder Standard type Both sides rubber cushion Both sides air cushion :Custom order, Center trunnion...

 Open the catalog to page 2
Tie rod cylinder SCG-3

Variation and option selection table : Standard : Option : Available (custom order) : Available depending on conditions X : Not available Port thread Double acting single rod type Non-rotating type Position locking type Low speed type Low friction type Rubber scraper type Coolant proof scraper (NBR) Coolant proof scraper (FKM) Spatter adherence prevention type Port thread With bellows (polyolefin material) Piston rod material stainless steel Copper and PTFE free type Customized piston rod end form Cylinder switch Rod eye Rod clevis Eye bracket Clevis bracket Eye bracket Trunnion type No. 2 bracket...

 Open the catalog to page 3
Tie rod cylinder SCG-4

Pneumatic components Safety precautions Always read this section before starting use. Refer to Intro 71 for general notes of cylinders and Intro 78 for cylinder switches. Design & Selection 2. Position locking type SCG-Q Install a flow control valve on the cylinder. Install a flow control valve on the cylinder. Use within the applicable piston speed range for each cylinder. Either a rubber or air cushion type cushion mechanism is assembled in the cylinder. The air cushion absorbs kinetic energy the piston acquires using air compression, and prevents the piston and cover from colliding at stroke...

 Open the catalog to page 4
Tie rod cylinder SCG-5

SCG Series 4. Coolant proof type SCG-G2/G3 3. Low friction type SCG-U Durability differs based on working conditions and model features. This cylinder is the cylinder which has internal leakage. Refer to the specification on page 392 for the internal leakage volume. Do not apply the deviated load onto the piston rod. It could shorten scraper and bearing life. If coolant or water do not get on the G2 or G3 series, the piston rod lubrication could be spent and shorten life. Use the G Series in this case. When a balancer, etc., is used, a flow control valve should not be installed if supply and...

 Open the catalog to page 5
Tie rod cylinder SCG-6

SCG Series Installation & Adjustment Supply a pressure higher than the minimum working pressure to the port having the locking mechanism. Precautions for switch installation Assembling the switch bracket When assembling the cylinder onto the switch bracket, fit the tie rod to be installed into the bracket, and move the switch so that it is at the center of the operation range (ON range). Then, tighten the fixing bolts with a tightening torque of 0.6 to 0.9 N·m. The bracket position (GC, DD) and switch positions (RD, HD) at which the maximum sensitivity is attained at both stroke ends are shown...

 Open the catalog to page 6
Tie rod cylinder SCG-7

SCG Series During Use & Maintenance 1. Position locking type SCG-Q Releasing the nonlocking manual override The stopper pin moves and the lock is released when the release SCM bolt is screwed into the stopper piston and the bolt is pulled up tion or when counter side port is pressurized). When the hand is released, if the stopper piston returns by the internal spring and CA/OV2 enters the piston rod groove, the piston is locked. SSD Release bolt Stopper spring Stopper piston When using the cylinder with air cushion, if the air cushion needle on the lock mechanism side is tightened too tight,...

 Open the catalog to page 7
Tie rod cylinder SCG-8

CMK2 CMA2 SCM SCG SCA2 SCS CKV2 CA/OV2 SSD CAT MDC2 MVC SMD2 MSD* FC* STK ULK* JSK/M2 JSG JSC3 USSD USC JSB3 LMB STG STS/L LCS LCG LCM LCT LCY STR2 UCA2 HCM HCA SRL2 SRG SRM SRT MRL2 MRG2 SM-25 CAC3 UCAC RCC2 MFC SHC GLC Ending

 Open the catalog to page 8
Tie rod cylinder SCG-9

Tie rod cylinder, double acting single rod type Bore size: Bore size Double acting Working fluid Withstanding pressure Ambient temperature Port size Rubber cushioned Working piston speed Effective air cushion length mm 30 to 1000 (use within the allowable energy absorption. ) Selection of air cushion and rubber cushion possible 13.4 Not required (when lubricating, use turbine oil Class 1 ISO VG32.) Allowable energy Rubber cushioned Stroke length Bore size (mm) Standard stroke length (mm) Max. stroke length (mm) Available stroke length (mm) Min. stroke length (mm) 700 32 Note 1: The custom stroke...

 Open the catalog to page 9

All CKD catalogs and technical brochures

  1. MN4GA / 4GB

    140  Pages

  2. MV3QR

    16  Pages

  3. 4G unit valve

    4  Pages

  4. SCP*3 Series

    60  Pages

  5. SCS2 series

    56  Pages

  6. LMD series

    15  Pages

  7. KBZ series

    64  Pages

  8. WXU series

    32  Pages

  9. AX6000M

    24  Pages

  10. SCS-G Series

    2  Pages

  11. CMK2 SR

    7  Pages

  12. SCPS2-MSeries

    4  Pages

  13. SCPD2 Serie

    3  Pages

  14. SCPD2 Series

    2  Pages

  15. SCPS Series

    1  Page

  16. SCM Series

    2  Pages

  17. GHV series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.