
Catalog excerpts

Safety Precautions Be sure to read this section before use. When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured. It is important to select, use, handle and maintain the product appropriately to ensure that the CKD product is used safely. Observe warnings and precautions to ensure device safety. Check that device safety is ensured, and manufacture a safe device. WARNING This product is designed and manufactured as a general industrial machine part. It must be handled by an operator having sufficient knowledge and experience. 2 Use this product in accordance with specifications. 1 This product must be used within its stated specifications. In addition, never modify or additionally machine this product. This product is intended for use in general industrial machinery equipment or parts. It is not intended for use outdoors (except for products with outdoor specifications) or for use under the following conditions or environments. (Note that this product can be used when CKD is consulted prior to its usage and the customer consents to CKD product specifications. The customer should provide safety measures to avoid danger in the event of problems.) 1 se for applications requiring safety, including nuclear energy, railways, aircraft, marine vessels, vehicles, medical devices, devices or applications U in contact with beverages or foodstuffs, amusement devices, emergency cutoff circuits, press machines, brake circuits, or safety devices or applications. 2 Use for applications where life or assets could be significantly affected, and special safety measures are required. Observe organization standards and regulations, etc., related to the safety of device design and control, etc. ISO4414, JIS B 8370 (Pneumatics fluid power - General rules and safety requirements for systems and their components) JFPS2008 (Principles for pneumatic cylinder selection and use) Including the High Pressure Gas Safety Act, Industrial Safety and Health Act, other safety rules, organization standards and regulations, etc. Do not handle, pipe, or remove devices before confirming safety. 1 Inspect and service the machine and devices after confirming safety of all systems related to this product. 2 Note that there may be hot or charged sections even after operation is stopped. 3 hen inspecting or servicing the device, turn OFF the energy source (air supply or water supply), and turn OFF power to the facility.Discharge any W compressed air from the system, and pay attention to possible water leakage and leakage of electricity. 4 hen starting or restarting a machine or device that incorporates pneumatic components, make sure that the system safety, such as pop-out W prevention measures, is secured. Observe warnings and cautions in the following pages to prevent accidents. The precautions are ranked as "DANGER", "WARNING" and "CAUTION" in this section. W DANGER: hen a dangerous situation may occur if handling is mistaken leading to fatal or serious injuries, and when there is a high degree of emergency to a warning. WARNING: If handled incorrectly, a dangerous situation may occur, resulting in death or serious injury. W hen a dangerous situation may occur if handling is mistaken leading to minor injuries or CAUTION: physical damage. Note that some items described as "CAUTION" may lead to serious results depending on the situation. Every item provides important information and must be observed. Warranty period The product specified herein is warranted for one (1) year from the date of delivery to the location specified by the customer. 2 Warranty coverage If the product specified herein fails for reasons attributable to CKD within the warranty period specified above, CKD will promptly provide a replacement for the faulty product or a part thereof or repair the faulty product at one of CKD’s facilities free of charge. However, following failures are excluded from this warranty: 1) ailure caused by handling or use of the product under conditions and in environments not conforming to those stated in the catalog, the F Specifications, or the Instruction Manual. 2) ailure caused by use of the product exceeding its durability (cycles, distance, time, etc.) or caused by consumable parts. F 3) Failure not caused by the product. 4) Failure caused by use not intended for the product. 5) Failure caused by modifications/alterations or repairs not carried out by CKD. 6) Failure caused by reasons unforeseen at the level of technology available at the time of delivery. 7) Failure caused by acts of nature and disasters beyond control of CKD. The warranty stated herein covers only the delivered product itself. Any loss or damage induced by failure of the delivered product is excluded from this warranty. Note: For details on the durability and consumable parts, contact your nearest CKD sales office. 3 Compatibility check The customer is responsible for confirming the compatibility of CKD products with the customer's systems, machines and equipment.
Open the catalog to page 1
Pneumatic control systems Safety Precautions Be sure to read this section before use. Refer to the General Catalog (No. CB-024SA) for general precautions. Product-specific cautions: Air booster ABP2 Series not use the air booster for continuous operation such as in a compressor. The Air Booster is a device for partial pressure increase in the factory. As with a compressor, its use in high frequency continuous operation will shorten its life. Use as a guideline 60 or less of the average operation cycle per minute. (Air boosters have a nominal life of 10 million cycles with normal use) Refer...
Open the catalog to page 2
foot bracket installed on both ends is available as an option. (ModelNo.ABP2-02-B) the air tank with the 4-ø11 anchor bolt hole on the bottom. of an air tank and regulator after the air booster is recommended for attaining stable secondary pressure. connecting the air booster directly to the air tank, fix the tank mounting base to the air booster with the included hexagon socket head cap screw, attach the included O-ring to the tank mounting base using the bottom port, and fix the air tank top with the hexagon socket head cap screw. Air booster IN Air booster Hex socket head cap screw Base...
Open the catalog to page 3All CKD catalogs and technical brochures
-
【NEW】ABP2-HP1・AT2 Series Catalog
16 Pages
-
FP Series Precautions
7 Pages
-
FP Series Introduction
10 Pages
-
FCM Series Variation list
1 Pages
-
【NEW】WFK2 Series Catalog
24 Pages
-
【NEW】WFK2 Series Precautions
6 Pages
-
MN4GA / 4GB
140 Pages
-
4GD1 to 3R, 4GE1 to 3R
261 Pages
-
MV3QR
16 Pages
-
4F ** 0EX series
28 Pages
-
Pilot operated 5-port valve
74 Pages
-
MV3QRA1/MV3QRB1 Series
20 Pages
-
PV5G/PV5/GMF/PV5S-0
76 Pages
-
4G unit valve
4 Pages
-
SCP*3 Series
60 Pages
-
SCS2 series
56 Pages
-
Rodless cylinder SRL3
89 Pages
-
Linear slide cylinder LCG
58 Pages
-
Linear slide cylinder LCM
52 Pages
-
Linear slide cylinder LCX
64 Pages
-
Guided cylinder STM
24 Pages
-
Cartridge cylinder CAT
6 Pages
-
Compact cylinder SSD
221 Pages
-
Compact cylinder SSD2
278 Pages
-
Guided compact cylinder SSG
16 Pages
-
Medium bore size cylinder SCS
46 Pages
-
Medium bore size cylinder SCA2
161 Pages
-
Tie rod cylinder SCG
87 Pages
-
Medium bore size cylinder CMK2
107 Pages
-
Round shaped cylinder SCM
116 Pages
-
Medium bore size cylinder CMA2
20 Pages
-
Pencil shaped cylinder SCP*3
60 Pages
-
LMD series
15 Pages
-
KBZ series
64 Pages
-
AGD21R-A series
4 Pages
-
WXU series
32 Pages
-
AX6000M
24 Pages
-
SCS-G Series
2 Pages
-
CMK2 SR
7 Pages
-
CMK2 Series Double acting
7 Pages
-
SSD-F/SSD-KF Series
1 Pages
-
CMK2-T Series
1 Pages
-
SCPS2-V Series
4 Pages
-
SCPD2-*C Series
1 Pages
-
SCPD2-K Series
3 Pages
-
SCPS2-MSeries
4 Pages
-
SCPD2-D/SCPD2-DT Series
3 Pages
-
SCPD2-F Series
2 Pages
-
SCPD2 Serie
3 Pages
-
SCPD2 Series
2 Pages
-
SCPS Series
1 Pages
-
SCM Series ø 20 to ø 63
2 Pages
-
SCM Series
2 Pages
-
GHV series
4 Pages
-
High purity gas systems
2 Pages
-
Component for chemicals
2 Pages
-
Labor-Saving products
8 Pages
-
General purpose valve
1 Pages
-
Pneumatic valves
8 Pages
-
Pneumatic cylinders
12 Pages