LMD series
15Pages

{{requestButtons}}

Catalog excerpts

LMD series - 1

Air-Operated Valve for Chemical Liquids LMD Series AIR-OPERATED VALVE FOR CHEMICAL LIQUIDS New series for the lineup of chemical liquid valves LMD Series has arrived!

Open the catalog to page 1
LMD series - 2

New series for the lineup of chemical liquid valves Light LMD Series has arrived! Air-Operated Valve for Chemical Liquids Orifice size 5 models Installation method Two-point fixed bracket to provide installation dimensions that are compatible with AMD Series Like the popular AMD part 3, the shape of the bracket is designed to provide space saving installation. High quality and high performance New type flared tube fitting * For the new flare-type fitting, contact CKD. Two-point (diagonal) attachment Easy to use with appropriate quality Option With flow adjustment With indicator Fluorine...

Open the catalog to page 2
LMD series - 3

XXXXX Series Air-Operated Valve for Chemical Liquids 1 2 3 Subject to Export Trade Control Ordinances * For those with Orifice ø16 and ø20 Working fluid Chemical liquids, pure water, air, N2 gas (Note 1) Fluid temperature Working pressure range (A→B) MPa See the figure “Allowable working pressure range” (below) Working pressure range (B→A) MPa See the figure “Allowable working pressure range” (below) Valve seat leakage cm /min 0 (under water pressure) Installation attitude Free FIT-ONE fitting made by BUENO TECHNOLOGY CO., LTD. Operation Operation pressure rangeMPa section Operation...

Open the catalog to page 3
LMD series - 4

With stiffening ring Operation port direction FIT-ONE fitting integrated type With indicator NC (Normally closed) NO (Normally open) Double acting With flow adjustment Option for metal coating (Note 2) Option for metal coating Blank Not coated C Coated E Operation port direction (Note 3) 4 In the overhead view, indicates the fluid flow direction, the operation port direction. Option for fitting set (Note 4) Blank With fitting set T Note on model no. selection Note 1: Precautions for operation port, stiffening ring and piping Stiffening ring can be omitted by leaving this section blank....

Open the catalog to page 4
LMD series - 5

Dimensions Blank ON • OFF Only, LMD**-*-*4*R 1 Flow path Operation port direction (R view) R view 10 With flow adjustment: LMD**-*-10*4*R Connected model number

Open the catalog to page 5
LMD series - 6

LMD5 Dimensions Blank ON • OFF Only, LMD5*-*-*4*R LMD5 Operation port direction (R view) 10 With flow adjustment: LMD5*-*-10*4*R

Open the catalog to page 6
LMD series - 7

Flow characteristics LMD3 to LMD5 Flow characteristics (water) Differential pressure - flow rate in ( ): Cv value 1000 Flow rate With flow adjustment (water) Number of rotations – flow P=0.2 MPa P=0.1 MPa Flow rate (ℓ/min) 120 160 3 2.5 3.5 Dial turn (Turns) Note 1: et the adjustment dial 1/4 round or more S open from the complete closed position. Using the product with less opening may cause vibration or fluctuation in flow depending on the working conditions.

Open the catalog to page 7
LMD series - 8

Related products Diaphragm-type cylinder valve LAD series eduction of particles R The particles are significantly reduced by using resin for all the wet areas and assembling in special environment. doption of port thread A Any appropriate pipe can be selected and connected. ow-pressure loss flow path L Effective sectional area is significantly increased by adopting the flow path design that drastically reduces pressure loss. In addition, it is energy saving. Air-operated valve for chemical liquids AMD part 3 series All-in-one model that supports various specifications /4”, 3/8”, 1/2”, 3/4”...

Open the catalog to page 8
LMD series - 9

Safety precautions Always read this section before starting use. When designing and manufacturing a device using CKD products, the manufacturer is obligated to check that device safety mechanism, pneumatic control circuit, or water control circuit and the system operated by electrical control that controls the devices is secured. It is important to select, use, handle, and maintain the product appropriately to ensure that the CKD product is used safely. Observe warnings and precautions to ensure device safety. Check that device safety is ensured, and manufacture a safe device. Warning 1...

Open the catalog to page 9
LMD series - 10

Disclaimer 1 Term of warranty “Warranty Period” is 18 months from the first delivery to the customer. In case any defect attributable to CKD is found during the Warranty Period, CKD shall, at its own discretion, repair the defect or replace the relevant product in whole or in part, according to its own judgment. Note that the following faults are excluded from the warranty term: (1) Product abuse/misuse contrary to conditions/environment recommended in its catalogs/specifications (2) Failure caused by other than the delivered product (3) Use other than original design purposes (4)...

Open the catalog to page 10
LMD series - 11

High purity chemical gas/liquid control systems Safety precautions Always read this section before starting use. Design & Selection orking environment W (1) Check compatibility between the material of each components and the working environment before using the product. (Do not use it in a corrosive environment or flammable environment.) (2) Make sure that fluids do not adhere to the product body. (3) Use the product within the ambient temperature range. (4) Do not use the product in a place with vibration or shock, a heat source neighborhood, or outdoors. Warning his product can not be...

Open the catalog to page 11
LMD series - 12

During Use & Maintenance f the product has the flow adjustment, set the I adjustment knob at a position of the specified number of rotations or more to the open direction from the complete closed position. Using the product with less opening may cause vibration or fluctuation in flow depending on the working conditions. There may be flow fluctuation caused by fluid temperature fluctuation depending on the use condition. Warning se within the maximum service pressure and U maximum working pressure range. CAUTION he compatibility check list on page 12 provides T basic information on...

Open the catalog to page 12
LMD series - 13

High purity chemical gas/liquid control systems Safety precautions Always read this section before starting use. WARNING ead the instruction manual thoroughly before R starting maintenance to ensure correct operation. lways turn the power OFF and release any fluids A or pressure before starting maintenance. hen conducting a maintenance or inspection W work, read the material safety data sheet (MSDS) of the chemical liquids used, and wear the required protective clothing. ong-term use of chemical liquids with high L permeability such as hydrochloric acid, hydrofluoric acid, and nitric acid...

Open the catalog to page 13

All CKD catalogs and technical brochures

  1. MN4GA / 4GB

    140 Pages

  2. MV3QR

    16 Pages

  3. SCP*3 Series

    60 Pages

  4. SCS2 series

    56 Pages

  5. KBZ series

    64 Pages

  6. WXU series

    32 Pages

  7. AX6000M

    24 Pages

  8. SCS-G Series

    2 Pages

  9. CMK2 SR

    7 Pages

  10. SCPD2 Serie

    3 Pages

  11. SCPD2 Series

    2 Pages

  12. SCPS Series

    1 Pages

  13. SCM Series

    2 Pages

  14. GHV series

    4 Pages

Archived catalogs