Catalog excerpts
Compliant with Internationally Consistent Explosion Proof Guidelines, Explosion proof capability Ex d IIB T4 Pilot-operated explosion proof 5 port valve 4F**0EX series EXPLOSION PROOF 5 PORT PILOT OPERATED VALVE Safely usable in hazardous atmosphere Compliant with IEC standard Compliant with Internationally Consistent Explosion-Proof Guidelines Pressure-resistant explosion-proof construction d Group II B Temperature class T4 Model inspection No. for model test No.TC20523 Usable outdoors Protection construction IP65 (dust-proof, jet-proof) Extended range of cable diameter selection ø7.5 to 13.5 lined up Obtained South Korea explosion-proof certification (KOSHA), Taiwan explosion-proof certification (ITRI)
Open the catalog to page 1Flow characteristics Series appearance No. of solenoid position JIS symbol Note 1 : Effective sectional area S and sonic conductance C are converted as S ^ 5.0 * C.
Open the catalog to page 2Discrete valve Pilot-operated explosion proof 5 port pneumatic valve Proof pressure explosion-proof structure Ex d IIB T4 (group IIB/temperature grade T4) Japan certified model inspection No. #TC20523 South Korea certified model inspection No. 15-AV4BO-0389 Taiwan certified model inspection No. Construction/electric (2015) #00216 Compatible cylinder bore size: 063 to 0250 Common specifications Electrical specifications (Ci) (C2) Note i: Ambient temperature refers to the temperature for storage and installation, and differs from fluid temperature, which applies during operation. Note i:...
Open the catalog to page 4Flow characteristics Note 1 : Effective sectional area S and sonic conductance C are converted as S ^ 5.0 * C. Rechargeable battery specifications The airflow passage and the material of the sliding sections are restricted to allow the unit to be used in the rechargeable battery manufacturing process. Contact CKD for types.
Open the catalog to page 5Discrete valve How to order • Explosion proof 5 port pneumatic valve [BSolenoid position > Explosion-proof certification authority | Symbol [CPort size A Note on model No. selection Note 1: For explosion-proof certification authority “KR” or “TW” “9” will be 98.5 to 99.5. Also, “13” cannot be selected. Note 2: Explosion-proof certification voltage 220 VDC outside of listed voltages will be handled as a special order. Note 3: When you order a coil, please order it as a pilot actuator assembly. Note 4: Contact CKD for using the unit for vacuum pressurization of an external pilot (K),...
Open the catalog to page 64F3*0EX Series Discrete valve; Body piping Internal structure and parts list 4F310EX
Open the catalog to page 7Discrete valve; Sub-plate piping Internal structure and parts list 4F|2OEX • 2-position double solenoid 4F63OEX, 4F54OEX 4Ff5OEX • 3-position All ports closed A/B/R connection P/A/B connection Main parts list Repair parts list
Open the catalog to page 84F3**0EX Series Discrete valve; Body piping ● L-type mounting leg (P) for single solenoid Solenoid valve 3-ø4.5 Solenoid valve Installation hole ● Position change of manual operating device (R) 51 Manual operating device R adaptor CKD
Open the catalog to page 9Discrete valve; Sub-plate piping Manual override 2-ø13 counter bore Depth 9 2-M8 depth 11 (Pilot hole ø7) 2-ø13 counter bore Depth 9 2-M8 depth 11 (Pilot hole ø7) 2-ø13 counter bore Depth 9 2-M8 depth 11 (Pilot hole ø7) Solenoid valve 2-ø8.5 Solenoid valve Installation hole
Open the catalog to page 10Discrete valve; Sub-plate piping 2-M8 depth 15 (Pilot hole ø7) 2-ø13 counter bore Depth 9 2-ø13 counter bore Depth 9 2-M8 depth 15 (Pilot hole ø7) 8-R3.3 Installation hole 2-ø8.5 Solenoid valve Installation hole 2-ø13 counter bore Depth 9 2-MA depth 15 (Pilot hole ø7)
Open the catalog to page 11Discrete valve; Sub-plate piping Manual override Manual override 2-ø16 counter bore Depth 15 2-M10 depth 15 (Pilot hole ø9) 2-M10 depth 15 (Pilot hole ø9) 2-ø16 counter bore Depth 15 8-R3.5 Installation hole 2-ø11 Solenoid valve Installation hole Manual override 2-M10 depth 15 (Pilot hole ø9) 2-ø16 counter bore Depth 15 Solenoid valve
Open the catalog to page 12Discrete valve; Sub-plate piping Manual override Manual override 2-ø20 counter bore Depth 16.5 2-M12 depth 23 (Pilot hole ø10.3) Manual override 2-ø14 Solenoid valve Installation hole 2-ø20 counter bore Depth 16.5 2-M12 depth 23 (Pilot hole ø10.3) 2-ø20 counter bore Depth 16.5 2-M12 depth 23 (Pilot hole ø10.3)
Open the catalog to page 13Individual wiring manifold Pilot-operated explosion proof 5 port pneumatic valve Proof pressure explosion-proof structure Ex d IIB T4 (group IIB/temperature grade T4) Japan certified model inspection No. #TC20523 South Korea certified model inspection No. 15-AV4BO-0389 Taiwan certified model inspection No. Construction/electric (2015) #00216 Compatible cylinder bore size: 063 to 0250 Common specifications Electrical specifications Note i: Ambient temperature refers to the temperature for storage and installation, and differs from fluid temperature, which applies during operation. Note i:...
Open the catalog to page 14Flow characteristics Note 1 : Effective sectional area S and sonic conductance C are converted as S ^ 5.0 * C. M4F**0EX Individual wiring manifold
Open the catalog to page 15Series Individual wiring manifold How to order Discrete solenoid valve for manifold (4F3) (^4F3^d) 0 EX(08-G(J0-(®' Discrete solenoid valve for manifold (4F4 to 7) C4F4^d> 9 EX-@-G@- O Enter the number of solenoid valves V°ltag»J Expl°sion-pr(X)f used in the case of mix manifold. certification authority (Refer to page 16 for examples of the description.)
Open the catalog to page 16M4F**0EX Series Individual wiring manifold How to order masking plate kit M4F3 A Port size Symbol Descriptions Model No. Port size * asket attached (M4F3) G Gasket and set screw attached (M4F4 to M4F7) * efer to the previous page for R other model indications. How to indicate mix manifold model numbers ①Indicate the quantity for each function (changeover position class) at the end of the model. Functions and symbols are indicated below. e.g.: 2-position single solenoid -> S1 Symbol Function (Solenoid position) S1 ② Enter the function (solenoid position) and layout position in the remark...
Open the catalog to page 17All CKD catalogs and technical brochures
-
【NEW】ABP2-HP1・AT2 Series Catalog
16 Pages
-
FP Series Precautions
7 Pages
-
FP Series Introduction
10 Pages
-
FCM Series Variation list
1 Pages
-
【NEW】WFK2 Series Catalog
24 Pages
-
【NEW】WFK2 Series Precautions
6 Pages
-
MN4GA / 4GB
140 Pages
-
4GD1 to 3R, 4GE1 to 3R
261 Pages
-
MV3QR
16 Pages
-
Pilot operated 5-port valve
74 Pages
-
MV3QRA1/MV3QRB1 Series
20 Pages
-
PV5G/PV5/GMF/PV5S-0
76 Pages
-
4G unit valve
4 Pages
-
SCP*3 Series
60 Pages
-
SCS2 series
56 Pages
-
Rodless cylinder SRL3
89 Pages
-
Linear slide cylinder LCG
58 Pages
-
Linear slide cylinder LCM
52 Pages
-
Linear slide cylinder LCX
64 Pages
-
Guided cylinder STM
24 Pages
-
Cartridge cylinder CAT
6 Pages
-
Compact cylinder SSD
221 Pages
-
Compact cylinder SSD2
278 Pages
-
Guided compact cylinder SSG
16 Pages
-
Medium bore size cylinder SCS
46 Pages
-
Medium bore size cylinder SCA2
161 Pages
-
Tie rod cylinder SCG
87 Pages
-
Medium bore size cylinder CMK2
107 Pages
-
Round shaped cylinder SCM
116 Pages
-
Medium bore size cylinder CMA2
20 Pages
-
Pencil shaped cylinder SCP*3
60 Pages
-
LMD series
15 Pages
-
KBZ series
64 Pages
-
AGD21R-A series
4 Pages
-
WXU series
32 Pages
-
AX6000M
24 Pages
-
SCS-G Series
2 Pages
-
CMK2 SR
7 Pages
-
CMK2 Series Double acting
7 Pages
-
SSD-F/SSD-KF Series
1 Pages
-
CMK2-T Series
1 Pages
-
SCPS2-V Series
4 Pages
-
SCPD2-*C Series
1 Pages
-
SCPD2-K Series
3 Pages
-
SCPS2-MSeries
4 Pages
-
SCPD2-D/SCPD2-DT Series
3 Pages
-
SCPD2-F Series
2 Pages
-
SCPD2 Serie
3 Pages
-
SCPD2 Series
2 Pages
-
SCPS Series
1 Pages
-
SCM Series ø 20 to ø 63
2 Pages
-
SCM Series
2 Pages
-
GHV series
4 Pages
-
High purity gas systems
2 Pages
-
Component for chemicals
2 Pages
-
Labor-Saving products
8 Pages
-
General purpose valve
1 Pages
-
Pneumatic valves
8 Pages
-
Pneumatic cylinders
12 Pages