1. Catalogs
  2. CITEL
  3. DDC30-20-65

DDC30-20-65

DDC30-20-65

Product catalog summary
Overview: The document provides technical specifications for the DDC30-20-65 DC power surge protector designed for 48 Vdc supplies. It is a 2-pole Type 1 + 2 surge protector with a pluggable module and optional remote signaling.
Specifications:
  • Nominal DC Voltage: 48 Vdc
  • Max AC Operating Voltage: 50 Vac
  • Max DC Operating Voltage: 65 Vdc
  • Nominal Discharge Current: 15 kA
  • Max Discharge Current: 30 kA
  • Impulse Current: 4 kA
  • Protection Level: 300 V / 600 V
  • Admissible Short-Circuit Current: 50,000 A
Mechanical Characteristics:
  • Technology: MOV
  • Configuration: 2-poles
  • Connection: Screw terminals
  • Mounting: Symmetrical rail 35 mm
  • Housing Material: Thermoplastic UL94 V-0
  • Operating Temperature: -40/+85°C
  • Protection Rating: IP20
  • Failsafe Mode: Disconnection from AC network
Additional Features:
  • Remote Signaling: Optional with DDC30S-20-65
  • Disconnection Indicator: 2 mechanical indicators (Red/Green)
  • Spare Module: MDDC30-65
Standards Compliance: prIEC 61643-41
Part Number: 828110112
See more

Catalog excerpts

DDC30-20-65-1

DC power surge protector - 48 Vdc Surge protector for DC supplies 2-pole Type 1 + 2 In: 15 kA / Imax: 30 kA Iimp: 4kA Pluggable module Remote signaling (option) prIEC 61643-41 compliance Electrical Characteristics SPD type Residual Current Leakage current to Ground Follow current Nominal discharge current 15 x 8/20 µs impulses Max. discharge current max. withstand @ 8/20 µs by pole Impulse current by pole max. withstand 10/350µs by pole Total lightning currentmax. total withstand @ 10/350µs Connection mode(s) Admissible short-circuit current Mechanical Characteristics Technology Housing material Operating temperature Protection rating Outdoor application Failsafe mode Disconnection from AC network Disconnection indicator 2 mechanical indicators - Red/Green Spare module(s) Remote signaling of disconnection Option DDC30S-20-65: output on changeover contact Wiring for remote signaling Max. Voltage/Current for remote signaling V: High-energy varistor Ft: Thermal fuse C: Remote signal contact t°: Thermal disconnection system MI: Disconnection indicator Disconnectors Thermal disconnector Standards Standards compliance CITEL • 2 rue Troyon • 92316 Sèvres Cedex • France • Tel: +33 1 41 23 50 23 • e-mail: [email protected] • citel.fr 20221216 - Docu