1. Catalogs
  2. Cirprotec
  3. EXTERNAL PROTECTION
video corpo

EXTERNAL PROTECTION

EXTERNAL PROTECTION
1 / 38 PagesView full catalog

EXTERNAL PROTECTION

Product catalog summary
Theory of Lightning Protection
Lightning poses significant risks due to its destructive effects, such as electrocution, structural damage, fires, and equipment destruction. Effective protection systems are crucial to mitigate these risks.
Lightning Protection Systems
These systems capture and safely conduct lightning to the ground. Key components include air terminals, down conductors, earthing systems, and surge protection devices. Certified products tested by accredited laboratories are emphasized for reliability and safety.
Regulatory Framework
International standards like NF C 17-102, UNE 21186, and IEC 62305 guide the design and implementation of lightning protection systems, assessing the need for protection and defining necessary components.
nimbus® Project Designer Software
This software aids in designing lightning protection systems by evaluating protection needs and optimizing ESE lightning rod placement. It generates comprehensive reports for project proposals.
nimbus® Early Streamer Emission Lightning Rods
The nimbus® series, including the nimbus® R, uses ESE technology for greater protection volume and cost savings. It accelerates upward leader formation, increasing the protected area.
Lightning Rods and Accessories
Components such as capture systems, lightning strike counters, down conductors, and earthing systems work together for comprehensive protection.
Cirprotec's Commitment to Safety and Innovation
With over 25 years of experience, Cirprotec emphasizes innovation, quality assurance, and compliance with international standards to ensure facility safety.
nimbus® Project Designer Features
  • Comprehensive Tool: Integrates facility drawing, risk assessment, and lightning rod placement optimization.
  • Automatic Calculation: Determines optimal lightning rod locations based on cost criteria.
  • Guided Process: A step-by-step process with contextual help, requiring no prior knowledge.
  • Risk Assessment: Calculates protection levels according to standards NF C 17-102:2011, UNE 21186:2018, and CTE SU08.
  • Technical Specification Tool: Provides a complete document for project specification.
  • Bill of Materials: Lists all necessary accessories for the lightning protection system.
Project Design Process
  • Project Data: Define project name, location, regulatory framework, and facility characteristics.
  • Drawing and Parameters: Import plans, draw installation perimeters, and set scales.
  • Risk Assessment: Select or calculate protection levels for each structure.
  • nimbus® Optimiser: Optimizes lightning rod placement and configuration.
  • Bill of Materials: Generates a comprehensive list of materials required.
  • Project Report: Compiles all data into a downloadable PDF report.
Additional Features
  • Web Application: Accessible on any OS and browser, no download required.
  • Multilingual Platform: Available in Spanish, English, and French.
  • Effective Project Management: Allows tracking, editing, and recalculating project details.
  • Compliance with Regulations: Adheres to ESE lightning protection standards.
nimbus® Lightning Rods
  • Robust Design: Exceeds standard requirements, tested for discharges up to 200 kA.
  • Global Presence: Over 45,000 units installed worldwide.
  • ESE Technology: Utilizes advanced electronic early streamer emission technology.
Specifications
Nimbus® lightning rods are made from AISI 316 stainless steel, ensuring high corrosion resistance. They comply with standards NF C 17-102:2011 and UNE 21186:2011, certified by Bureau Veritas, and withstand lightning currents up to 200 kA.
Quality Assurance
Nimbus® products are Bureau Veritas certified, ensuring rigorous type tests and audited production processes. A laser-marked QR code on each product allows customers to verify authenticity and compliance with standards.
Maintenance and Testing
Regular maintenance of lightning protection systems is mandated by regulations. Nimbus® rods can be tested on-site using the LR-tester, while the nimbus® R series offers remote testing capabilities with the R-Tester.
Remote Testing
The nimbus® R series incorporates remote verification technology, allowing for testing without physical access to the rod.
Lightning Discharge Counter
The CDR-401 is an open-core lightning strike counter, compliant with standards EN 50164-6, EN 62561-6, and UTE C 17106, protected against dust and immersion (IP67).
Installation Accessories
Includes masts, support poles, and anchorages made from galvanized or stainless steel for durability.
Conclusion
Nimbus® lightning rods offer high-quality materials, compliance with international standards, and innovative features like remote testing and QR code verification to ensure authenticity and performance.
Component Specifications
  • Down Conductor System: Includes kits for mast-antenna and equipotential protection, using stainless steel and plastic materials.
  • Supports: Pyramidal conductor holders, roof tile conductor holders, and metallic roof clamps.
  • Clamps: Bronze and nylon cable clamps, copper tape clamps, and concrete wall staples.
  • Connecting Sleeves: Steel and brass connection sleeves for maintenance.
  • Protection Pipes: Made from polyethylene and galvanized steel.
  • Earthing System: Includes earthing inspection pits, warning signs, earth rod clamps, rods, plates, and enhancing compounds.
Contact Information
CIRPROTEC, S.L.U., located in Terrassa, Barcelona, Spain, provides contact details for various regions including Europe, Middle East, Africa, America, and Asia-Pacific.
See more

Catalog excerpts

EXTERNAL PROTECTION-1

EXTERNAL LIGHTNING PROTECTION SYSTEMS nimbus® LIGHTNING

 Open the catalog to page 1
EXTERNAL PROTECTION-3

Cirprotec, your protection partner SPECIALIST IN LIGHTNING AND SURGE PROTECTION Pioneers in the design and manufacture of lightning and surge protection devices, Cirprotec has been manufacturing high quality solutions and products for over 25 years using the most innovative technologies. Cirprotec's leadership in this field is supported by its clear commitment to innovation and the latest trends. An example of this is the new nimbus® R lightning rod series, an online IOT cloud-based monitoring system, for convenient monitoring of events and maintenance. SAFETY AND RELIABILITY • Bringing together...

 Open the catalog to page 3
EXTERNAL PROTECTION-4

Lightning | The need for protection THE PHENOMENON OF LIGHTNING At any one time there are about 5,000 active thunderstorms around the world. Lightning density depends on the terrain and climate, which means it varies from one place to another and from one time of year to another. In Spain, for example, some two million lightning bolts fall to earth, killing a dozen people and hundreds of animals each year. Lightning is a powerful natural discharge of static electricity, produced during a thunderstorm and generating an electromagnetic pulse. Under normal conditions, there is a balance between...

 Open the catalog to page 4
EXTERNAL PROTECTION-5

Lightning | Effective protection REGULATORY FRAMEWORK PRODUCT CERTIFICATION The destructive capacity of lightning makes it necessary to assess the need for protection, and possibly to install an effective protection system. Due to its construction and accessibility, an ESE lightning rod is designed for high durability, and accessing and replacing it is usually complicated and expensive. So it is especially important for it to be certified and have undergone tests (mechanical, climate chambers, current impulses) in accordance with the above standards, which guarantee its reliability and robustness....

 Open the catalog to page 5
EXTERNAL PROTECTION-6

Lightning protection system The destructive capacity of the lightning makes it essential to evaluate the need for protection and, perhaps, to install a system to ensure effective protection. The current regulatory framework in each country defines the need for protection and sets out the steps to follow for designing a system which guarantees protection against lightning. ASSESS THE NEED FOR PROTECTION The need for protection of a facility is established starting from the evaluation of the degree of safety required and associated risk factors. Whenever the expected strike frequency (Ne) is greater...

 Open the catalog to page 6
EXTERNAL PROTECTION-7

Lightning rods | ESE Technology THE MOST EFFICIENT SYSTEM ESE (Early Streamer Emission) technology uses the atmospheric gradient to generate ionization which creates an upward propagating leader faster than any Franklin passive rod. The time difference ΔT is the "benefit" of ESE technology and is known as "early emission" (microseconds µs). Downward leader Strike point Upward leader (streamer) By reducing the start time, the streamer can be connected to the descending leader at a virtually located strike point well above the tip of the ESE lightning rod. This substantially increases the protected...

 Open the catalog to page 7
EXTERNAL PROTECTION-8

PROJECT DESIGNER Tool for the complete design of an external lightning protection system. Comprehensive tool All the tools you need for facility drawing, risk assessment, optimisation of lightning rod placement and generation of technical documentation integrated into a single piece of software.

 Open the catalog to page 8
EXTERNAL PROTECTION-9

nimbus® project designer software LIGHTNING SYSTEM PROTECTION DESIGN FOR ANY TYPE OF FACILITY

 Open the catalog to page 9
EXTERNAL PROTECTION-10

Lightning system protection design software The nimbus® project designer is a free online tool which allows users to create the complete design of a lightning protection system, from analyzing the risks in accordance with the current regulations, to automatically calculating the optimal number and location of nimbus® lightning rods. The software provides a valuable document detailing the data and calculations for the specification of the project, facilitating the preparation of quotes. The results of the project are compiled in a report that includes general aspects related to the project in...

 Open the catalog to page 10
EXTERNAL PROTECTION-11

Easy, fast and optimised project design GUIDED PROCESS AUTOMATIC LIGHTNING ROD CALCULATION Thanks to a linear process, and guided by an assistant with contextual help, defining projects becomes a simple task. No previous knowledge is required. The algorithm developed by Cirprotec allows the optimal location of nimbus® lightning rods and earthings using cost criteria. EASY DEFINITION OF THE PROTECTION AREA Complete and simple drawing tool with drawing import. RISK ASSESSMENT Calculations of the level of protection in accordance with current standards NF C 17-102:2011, UNE 21186:2018 and CTE SU08....

 Open the catalog to page 11
EXTERNAL PROTECTION-12

nimbus® project designer | Step by step RESOLVE YOUR PROJECTS RAPIDLY AND INTUITIVELY nimbus® project designer is an online software tool which provides the designer with the necessary tools for the design of lightning protection projects. A linear process allows the user to be guided by the assistant through a set of “stations” which configure the data and decisions which determine the scope of the external lightning protection project, in all cases allowing it to be edited or modified. Project data Cirprotec https://nimbus.cirprotec.com These steps are detailed as follows: Project data PROJECT...

 Open the catalog to page 12
EXTERNAL PROTECTION-13

Drawing and parameters Cirprotec Risk assessment Cirprotec Project data nimbus® optimiser Risk assessment Project report Project data nimbus® optimiser Risk assessment Risk calculation results The level of protection must be Name of risk assigned or calculated for at least one structure. Loss of human life (R1) Calculated risk Loss of essential services (R2) Assign protection level Loss of cultural heritage (R3) Structure options Project report Help: Changes are saved automatically. Indicate the height and materials for the structure. In the column CALCULATED RISK you will have to check that...

 Open the catalog to page 13
EXTERNAL PROTECTION-14

Design using the most advanced software FEATURES nimbus® project designer is the result of Cirprotec's extensive experience in the design and dimensioning of lightning protection systems. This software provides the designer with the set of tools needed for the efficient solution of projects. • Free access for any number of projects By just registering, you will have access to all the functions of the software and you can carry out any number of projects, with no limit to the number of lightning rods. • Web application Since it is a web application it does not require a download or installation,...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.