Product catalog summary
Overview: Cirprotec specializes in designing and manufacturing lightning, surge, and overvoltage protection devices. Their products, compliant with international standards like IEC, UL, and ISO certifications, are designed for both internal and external protection, including grounding systems and insulation monitors.
Specifications: The document details the CPS block and CPS nano series, which are surge protective devices (SPDs) compliant with UL 1449 3rd Edition. These devices protect against transient voltage surges from lightning or switching operations.
Protection Mechanism: SPDs function as voltage-controlled switches, diverting excess voltage to the ground when it exceeds a threshold, thus safeguarding connected equipment. Selection depends on network topology, nominal voltage, and surge exposure.
Installation and Selection: Emphasizes selecting the right SPD based on surge exposure and discharge capacity. A cascade system is recommended for optimal protection, with SPDs classified by installation location and exposure rating.
Product Features: The CPS nano and CPS nano plus models are noted for their compact design, ease of installation, and features like the Redundant Multi Discharge System (MDS), EMI/RFI filters, and intelligent aging display (IAD®). They offer remote end-of-life indication and suit various network configurations.
Technical Specifications: Detailed specifications for the CPS nano and CPS nano plus include maximum discharge capacity, nominal discharge current rating, voltage protection rating, and enclosure type, designed for different phase configurations and voltage ratings.
Conclusion: Cirprotec's SPDs enhance equipment life, ensure service continuity, and reduce maintenance costs, positioning them as a reliable partner in surge protection.
Additional Overview: The document also covers the CPS block and CPS block plus models, designed for main or distribution panels to protect against electrical surges.
Additional Specifications:
  • Classification: Type 2 (UL 1449 3rd Edition) and Class II (IEC 61643-11).
  • Protection Modes: Common and differential mode protection.
  • Nominal Voltage Rating: 120V to 480V across various configurations.
  • MCOV: 175V to 510V depending on configuration.
  • Maximum Discharge Capacity: CPS block 120-200 kA per phase, CPS block plus 120-240 kA per phase.
  • Nominal Discharge Current: 20 kA per phase.
  • Voltage Protection Rating: Varies by configuration.
  • SCCR: 100 kA for CPS block, 200 kA for CPS block plus.
  • Response Time: 1 ns.
  • Enclosure Type: CPS block IP 66/NEMA 4, CPS block plus IP 55/NEMA 12.
Additional Features:
  • Modular Construction: Easy maintenance and module replacement.
  • Intelligent Aging Display (IAD®): End-of-life indication with LEDs.
  • Multi-Discharge System (MDS): Varistor technology with individual MOV disconnection.
  • Dynamic Thermal Disconnection: Safety through overheating disconnection.
  • Remote Indication: End-of-life alerts.
  • EMI/RFI Filter: Reduces electromagnetic interference.
  • Surge Counter: Available in CPS block plus for tracking surge events.
Applications: Suitable for various networks and voltages, providing comprehensive protection and reducing maintenance costs, ideal for high exposure environments.
Contact Information: For more information, contact Cirprotec at their Barcelona office or visit their website.
See more

Catalog excerpts

CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-1

UL U49 3rd Ed. Surge protective devices (SPD) Transient voltage surge suppressors (TVSS]

 Open the catalog to page 1
CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-2

Cirprotec, more than just protection Cirprotec, specialists in lightning and surge protection. Your protection partner. Cirprotec is a pioneer in the design and manufacture of lightning, surge and overvoltage protection devices. It has an extensive network of sales offices and is present in over 60 countries. We have everything you need. Total solution: protection, monitoring and safety. Cirprotec offers a wide range of lightning and overvoltage protection solutions: Internal protection (transient and power frequency overvoltage protectors) External protection (ESE lightning rods and Faradization)....

 Open the catalog to page 2
CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-3

We are manufacturers. Quality assurance. Cirprotec answers for its products. This by controlling all stages of the process: we have a number of design, manufacturing and production centers and laboratories. Designed and manufactured entirely in Europe in accordance with local and international standards such as IEC, UL, EN, IEEE, NFC, VDE, UNE always under the control of ISO 9001 and 14001 quality assurance. Serving energy efficiency. Innovations for new applications. Cirprotec is committed to innovation: A highly specialized team, test laboratories, high investment in R&D&i, international patents...

 Open the catalog to page 3
CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-4

Why protect Transient overvoltages are voltage surges that can reach tens of kilovolts with a duration of the order of microseconds. This type of surge can have various different causes, including atmospheric lightning direc tly striking the ex ternal protection (lightning rod) on a building or transmission line or the associated induction of ele c tr o m a gnetic f iel d s o n m et al l ic conductors. It is also common for non-weather phenomena, such as transformer center switching or the switching off of motors or other inductive loads to cause voltage spikes in adjacent lines. Voltage surges...

 Open the catalog to page 4
CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-5

Transient voltage surges General operation and selection How a protector works. A surge protective device acts as a voltagecontrolled selector switch and is installed between the active conductors and earth in parallel to the equipment to be protected. When the network voltage is lower than the activation voltage, the protector acts as a high-impedance element, so that no current passes through it. On the other hand, when the network voltage exceeds the activation voltage, the protector acts as a near-zero impedance element, deriving the surge to earth and preventing it affecting the receivers....

 Open the catalog to page 5
CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-6

Protection Implementing the protec parameters according S elec ting an SPD depends on t wo f ac tor s: the location categor y, which differentiates the to UL 1449 3rd Ed parts of the installation according to the type Imax MAXIMUM DISCHARGE CAPACITY Maximum peak current, per phase, in 8/20 μs wave that the protection device is able to withstand. NOMIN A L DISCH A RGE CURRENT RATING Peak current in 8/20 μs wave that the protection device can withstand on 15 occasions without reaching the end of its service life. VOLTAGE PROTECTION RATING This indicates the maximum residual voltage between the...

 Open the catalog to page 6
CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-7

ction according to IEEE C62.41.2-2002: Scenario 1 (conducted and induced surges) Location A Main Panel Service Entrance Main Panel Outbuilding Service Entrance Underground Service Long-distance circuits and individual equipment Outbuilding, service entrance and main panel Main panel, distribution panels and shortdistance circuits UL type used Exposure rating Imax (8/20 µs) [kA] per phase CPS Block + CPS Block CPS nano + CPS nano

 Open the catalog to page 7
CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-8

CPS block & block plus UL & IEC Duality The CPS nano range brings together Cirprotec's experience of the principal international manufacturing and test standards for SPDs Modular Each protection mode can be individually replaced if it reaches end of life. This allows for efficient preventive maintenance. MDS Redundant Multi Discharge System varistor technology with individual disconnection of each MOV EMI / RFI Filter All models include an electromagnetic filter for network noise. IAD® The intelligent aging display (IAD®) provides visual information about the remaining percentage of protection...

 Open the catalog to page 8
CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-9

CPS nano & nano plus UL & IEC Duality The CPS nano range brings together Cirprotec's experience of the principal international manufacturing and test standards for SPDs EMI / RFI Filter All models include an electromagnetic filter for network noise. MDS Redundant Multi Discharge System varistor technology with individual disconnection of each MOV IAD® The intelligent aging display (IAD®) provides visual information about the percentage of protection available from CPS nano plus (100%, 50% early alert, 0%) Nema 4 Both models are highly watertight (Nema 4 / IP66) Remote indication The IR Remote...

 Open the catalog to page 9
CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-10

CPS nano Non-modular Surge Protective Device (SPD) designed according to standards UL 1449 3rd ed. and IEC 61643-11 for installation in main panels or distribution panels and for the specific protection of critical loads. Compact and easy to install, the CPS nano provides comprehensive protection for a wide range of networks and voltages. Features • Type 2, “Permanently connected” SPDs intended for installation on the load side of the service equipment (main panel) overcurrent device; including SPDs located at the branch panel. • Maximum 8/20 discharge capacity (Imax) from 40 to 120 kA per phase....

 Open the catalog to page 10
CPT-Cirprotec-V4-SURGE-PROTECTIVE-DEVICES-UL-1449-3rd-Ed-CPS-11

Specifications Split Phase Classification according to UL 1449-3rd Edition Protection modes Common and differential mode protection Nominal voltage rating AC 50-60 Hz Maximum continuous operating voltage AC 50-60 Hz Maximum discharge capacity per phase / Nominal discharge capacity per phase Voltage protection rating (L-N/L-G/N-G) Voltage protection rating (L-L) Voltage protection rating (LHL-N/LH-G) Voltage protection rating (LHL-L) Maximum back-up fuse Short-circuit current rating Response time Dynamic thermal disconnection Enclosure type Selection Guide Imax / phase Split Phase Insulating material...

 Open the catalog to page 11