Catalog excerpts
Control relays Current detector control relay Description The WI current detectors are electronic devices with an output relay that is connected or disconnected, in accordance with the level of current detected in the circuit. }} trip level is adjusted with the potentiomThe eter on the front of the unit. }} The reset process is automatic with currents under 10% of the trip level (Hysteresis). }} Delay: the connection and disconnection times of the output relay can be adjusted separately. }} Measurement of the current, depending on the type: yy With built-in current transformer (net diameter ∅ 25 mm) yy Separate transformer, input.../5 Aac Features Power supply circuit Voltage* Testing voltages between the circuits and the grid Measurement circuit Relay contacts Output relay Insulation voltage (Ui) Interrupting power (105 operations) with resistive load Ue/Ie: 240 Vac / 3.2 A with inductive load Ue/Ie: 240 Vac / 0.8 A 30 Vdc / 1.6 A Build features WIs can be used in any application that needs to control the load: Operating temperature Standards IEC 605, IEC 1010-1, EN 61010-1, EN 50 081, EN 50 082, IEC 255, UL 94, UNE 20 607, UNE 21 136, VDE 0110 (*) Other voltages and frequencies on demand. }} Power supply units for grinders or aggregate grinding units. }} Loads in extrusion machines }} Pump control }} Load on motors, etc.
Open the catalog to page 1Control relays Current detector control relay References Trigger time (adjustable) Adjustment margin (adjustable) Connections With separate transformer With built-in transformer Current to control Current to control S1 Current to control Current to control Power supply Power supply 230 Vac Vac 230 Power supply Power supply 230 Vac Vac 230
Open the catalog to page 2All CIRCUTOR catalogs and technical brochures
-
Filtering solutions
16 Pages
-
BC48 15V
4 Pages
-
DCB, Digital instruments
2 Pages
-
WRU-10, Smart protection
2 Pages
-
REC4, Self-reclosing RCCB
8 Pages
-
Electric Vehicle Charging
8 Pages
-
Solutions for AMI systems
20 Pages
-
Solutions for ISO 50001
12 Pages
-
TCP2RS+
4 Pages
-
LM4I4O-M
4 Pages
-
Solar photovoltaic canopies
8 Pages
-
Solutions for Self-consumption
16 Pages
-
MYeBOX Connected to efficiency
12 Pages
Archived catalogs
-
Short-Form 2021
162 Pages
-
CSB
2 Pages
-
RG1M
2 Pages
-
RGE
2 Pages
-
WGC series
2 Pages
-
RGU10
2 Pages
-
LVC
1 Pages
-
TSA
2 Pages
-
R-RE-RBE
2 Pages
-
CLZ-FP-HD
5 Pages
-
CV
2 Pages
-
computer MAX
2 Pages
-
LR-LRB
3 Pages
-
CR Series
1 Pages
-
MCB
2 Pages
-
WGBU
3 Pages
-
C80
4 Pages
-
AR5L
9 Pages
-
TSR
1 Pages
-
C-convert
9 Pages
-
MEG
2 Pages
-
SYNCHROMAX
3 Pages
-
UC Series
3 Pages
-
SMC-STC
3 Pages
-
FMZ-FTZ
3 Pages
-
WMC-WTC
5 Pages
-
EC-V
5 Pages
-
EC-A
5 Pages
-
RAPTION 150
2 Pages
-
URBAN
2 Pages
-
CVM-A Series
7 Pages
-
BM-V
3 Pages
-
PGR Series
2 Pages
-
SGE-PLC Series
2 Pages
-
LM4I/4O-M
2 Pages
-
RGU-10B
2 Pages
-
CEM-C20
2 Pages
-
CEM-C10
2 Pages
-
OPTIM-HYB
2 Pages
-
RVE2-P
2 Pages
-
cSMARTIII
2 Pages
-
AR6
2 Pages
-
CVM-C5
2 Pages
-
FRE
2 Pages
-
MT-FDE
2 Pages
-
RECmaxMP
2 Pages
-
RECmaxLPD
2 Pages
-
CBS4
2 Pages
-
RGU2
2 Pages
-
CIRWATT-B100
2 Pages
-
FEMC-FETC
3 Pages
-
HC
2 Pages
-
BC-V
3 Pages
-
BC-A
3 Pages
-
TL-5
1 Pages
-
CIRWATT-B505
2 Pages
-
CIRWATT B 502
2 Pages
-
CVM Power analyzers
40 Pages
-
Type B
8 Pages
-
C-FLEX Series
4 Pages
-
MS
1 Pages
-
FLEX-R
1 Pages
-
CIRWATT B 410T
3 Pages
-
TRMC
2 Pages
-
RS2RS
1 Pages
-
ReadWatt
2 Pages
-
Módem Router 3G
2 Pages
-
DIR2
1 Pages
-
computer Smart
2 Pages
-
Smart earth leakage protection
32 Pages
-
ANALOGUE INSTRUMENTS
64 Pages
-
DIGITAL INSTRUMENTS
34 Pages