Connection with only 2 wires Technical features Electrical insulation Maximum assigned service Voltage 2 wire terminal connection that facilitates the installation. Measurement circuit Operating conditions Mechanical features DIN rail accesory The WGC transformers have an accessory for the DIN rail makes their installation even easier. Assigned impulse Voltage / pollution Assigned transformation ratio, Kn Accuracy in measurements Direct thermal current Short-circuit thermal current, Ith Dynamic current, Idyn Operating temperature Relative humidity Maximum altitude Terminal protection Screw down fasteners DIN Rail (con accesorio) Casing material / Colour Self-extinghishing class Product standards 95% 2000 m IP 20 (IEC 60529) M-5 See Code Lexan 923 / RAL 7035 UL 94V-0 IEC 60044-1 Screw down fasteners (screw type pzl) 0,1 a 2,5 mm2 / 27 ... 12 AWG Two wire (S1-S2) connection type Dimensions of rigid/flexible conductors Connection to the Cabling with wire section ≥ 1 mm2 protection and measurement Cabling of braided and devices (RCD,RCM) shielded wire section ≥ 1 mm2 Code P10151 P10152 P10153 P10154 P10155 P10156 P10157 P10158 P10159 P10160 P19921 Earth leakage transformers optimized for the installation Better inmunity www. circutor. com CIRCUTOR, SA - Vial Sant Jordi, s/n 08232 Viladecavalls (Barcelona) Spain Tel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 [email protected] Technology for energy efficiency Designed by: Communication Dept. - CIRCUTOR, SA.
Open the catalog to page 1Earth leakage transformers Electronic relay range of earth leakage protection and monitoring compatible with WGC This new range presents a series of improvements above all in the installation of equipment in switchboards. Along with the usual installation fixtures, we add the possibility of doing it with a DIN rail by means of an accessory, which would facilitate its installation. The WGC series earth leakage transformers have a greater immunity to transitory type current peaks that usually cause differential protection triggers. Adjustable sesitivity and delay time Prealarm Display RGU-10 Class...
Open the catalog to page 22 Pages
4 Pages
2 Pages
8 Pages
8 Pages
20 Pages
12 Pages
4 Pages
4 Pages
8 Pages
16 Pages
12 Pages
34 Pages
32 Pages
64 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
4 Pages
8 Pages
3 Pages
2 Pages
2 Pages
1 Page
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
7 Pages
2 Pages
2 Pages
5 Pages
5 Pages
5 Pages
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
9 Pages
1 Page
9 Pages
4 Pages
3 Pages
2 Pages
1 Page
3 Pages
2 Pages
2 Pages
5 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
40 Pages
2 Pages
2 Pages
162 Pages