1. Catalogs
  2. CIRCUTOR
  3. Solutions for analysis & management for installations

Solutions for analysis & management for installations
1 /12Pages

Solutions for analysis & management for installations

Solutions for analysis & management for installations
1 /12Pages

Catalog excerpts

Solutions for analysis & management for installations-1

Solutions for analysis & management for installation

 Open the catalog to page 1
Solutions for analysis & management for installations-3

 Solutions for analysis & management for installations Having information is essential to know, be aware of and take actions that lower energy costs and improve the operations of facilities. By installing power analyzers, you can determine how, where, when and how much energy you are consuming in your installation. Once connected to the management software, you can track your consumption over time. This will make it possible to view consumption trends and identify areas of improvement so that you can apply corrective measures, assess their benefits and quickly detect any abnormal or inefficient...

 Open the catalog to page 3
Solutions for analysis & management for installations-4

4 | Solutions for analysis & management for installations ENERGY ME A SUREMENT AND MANAGEMENT Power analyzers CVM power analyzers with expansion modules. K E Y F E AT U R E S Installation in DIN Rail or Panel A wide range of devices in different formats for installing on any type of surface. Control with inputs/outputs Circutor analyzers have inputs for reading pulses from different energy sources or for checking a status (sensors, protection devices, etc.), and outputs for generating alarms for any instantaneous parameter. Power quality management Monitors power quality as per IEC 61000-4-30,...

 Open the catalog to page 4
Solutions for analysis & management for installations-5

Solutions for analysis & management for installations | 5 Flexible sensors to measure current (FLEX). Expandable with multiple inputs/outputs Version with EMSi system NEW New complete range of self-detectable Line devices. Easy set-up without the need to connect power supply or communications cables. FLEX versions Devices that can be installed without the need to interrupt or shut off the electrical supply, thanks to the use of FLEX flexible clamps. Calculate financial costs The analyzers show the cost associated with any type of energy consumption, both general and that associated with production...

 Open the catalog to page 5
Solutions for analysis & management for installations-6

6 | Solutions for analysis & management for installations ENERGY ME A SUREMENT AND MANAGEMENT Power analyzers for any point in the installation W H E R E T O I N S TA L L T H E A N A LY Z E R S Main Distribution Board CVM-A1500A Secondary Board Distribution Boards Circutor. The Future is Efficiency

 Open the catalog to page 6
Solutions for analysis & management for installations-7

Solutions for analysis & management for installations | 7 ENERGY ME A SUREMENT AND MANAGEMENT Full range of power analyzers QUICK SELEC TION Installation in PANEL Three-phase with indirect connection 96x96 mm ITF (.../5 A; .../1 A) FLEX sensors FLEX sensors Modbus RTU / BACnet / Webserver / HTML5 / XML Ethernet (Web server) + RS-485 2 Digital outputs + 2 Relay outputs + 2 Digital inputs Neutral current + 31st harmonics Neutral current + 50 th harmonics Neutral current + 63rd harmonics Power quality Datalogger (optional) DIN rail installation AC networks Direct single-phase Direct three-phase...

 Open the catalog to page 7
Solutions for analysis & management for installations-8

8 | Solutions for analysis & management for installations ENERGY ME A SUREMENT AND MANAGEMENT Power analyzers for AC networks NEW Power quality analyzer Power analyzer Class A certificate as per IEC 61000-4-30 EN 50160 Analysis Logging of events and transients Class 0.2S in active energy .../5 A; …/1 A; .../250 mA or FLEX Memory (1 year of data) EMS software with integrated web server Up to 3 expansion modules Ethernet Datalogger Modbus Up to 400 variables Class 0.5S in active energy .../5 A; .../1 A Neutral current 3 tariffs RS-485 (Modbus/BACnet) Up to 31st harmonic Wave form Flex optional...

 Open the catalog to page 8
Solutions for analysis & management for installations-9

Solutions for analysis & management for installations | 9 ENERGY ME A SUREMENT AND MANAGEMENT Power analyzers for AC networks CVM-E3-MINI Power analyzer Power analyzer Up to 400 variables Class 1 in active energy .../5 A; .../1 A or.../250 mA or FLEX Up to 31st harmonic Up to 400 variables Class 1 in active energy .../5 A; .../1 A or .../250 mA or FLEX Up to 31st harmonic Flex optional Flex optional Power analyzer Up to 500 variables Class 1 in active energy .../5 A; .../1 A or .../250 mA Up to 40th harmonic Event counter I/O expandable Line-M-4IO-R → 4 digital inputs + 4 relay outputs Line-M-8I6O...

 Open the catalog to page 9
Solutions for analysis & management for installations-10

10 | Solutions for analysis & management for installations ENERGY ME A SUREMENT AND MANAGEMENT Power analyzers for AC networks NEW Energy meter with analysis of electrical variables Energy meter with analysis of electrical variables Direct three-phase measurement 65 A 3x 230 V/400 V Class 1 in active energy (IEC 62053-21 ) Class 2 in reactive energy ( IEC 62053-23 ) V, A, kW, kvar, kWh, Kvarh, Hz, CO2, energy cost Direct single-phase measurement 100 A 1x 230 V Class 1 in active energy (IEC 62053-21) Class 2 in reactive energy ( IEC 62053-23 ) V, A, kW, kvar, kWh, kvarh, Hz, CO2, energy cost 3...

 Open the catalog to page 10
Solutions for analysis & management for installations-11

Solutions for analysis & management for installations | 11 ENERGY ME A SUREMENT AND MANAGEMENT Current transformers to analyze AC networks TD Closed-core transformers Open-core transformers I From 40 A to 4000 A I …/5 A ; .../1 A or.../250 mA I DIN connection Panel or busbar/cable I Sealable I Flange fastening I Encapsulated (optional) I Low losses I From 100 A to 1000 A I …/5 A ; .../1 A or.../250 mA I DIN connection/Panel or busbar/ cable I Button release to open I Sealable I Low losses Efficient single-phase transformers Efficient three-phase transformers Single-phase connection From 50 A...

 Open the catalog to page 11
Solutions for analysis & management for installations-12

Vial Sant Jordi, s/n 08232 Viladecavalls Barcelona (Spain) t. +34. 93 745 29 00 [email protected] C2M5G3. CIRCUTOR, SAU reserves the right to modify any information contained in this catalogue.

 Open the catalog to page 12

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4  Pages

  2. TCP2RS+

    4  Pages

  3. LM4I4O-M

    4  Pages

Archived catalogs

  1. DIR2

    1  Page

  2. ReadWatt

    2  Pages

  3. RS2RS

    1  Page

  4. FLEX-R

    1  Page

  5. MS

    1  Page

  6. C-FLEX Series

    4  Pages

  7. Type B

    8  Pages

  8. CIRWATT B 502

    2  Pages

  9. CIRWATT-B505

    2  Pages

  10. TL-5

    1  Page

  11. BC-A

    3  Pages

  12. BC-V

    3  Pages

  13. HC

    2  Pages

  14. FEMC-FETC

    3  Pages

  15. CIRWATT-B100

    2  Pages

  16. RGU2

    2  Pages

  17. CBS4

    2  Pages

  18. RECmaxLPD

    2  Pages

  19. RECmaxMP

    2  Pages

  20. MT-FDE

    2  Pages

  21. FRE

    2  Pages

  22. CVM-C5

    2  Pages

  23. AR6

    2  Pages

  24. cSMARTIII

    2  Pages

  25. RVE2-P

    2  Pages

  26. OPTIM-HYB

    2  Pages

  27. CEM-C10

    2  Pages

  28. CEM-C20

    2  Pages

  29. RGU-10B

    2  Pages

  30. LM4I/4O-M

    2  Pages

  31. TRMC

    2  Pages

  32. PGR Series

    2  Pages

  33. BM-V

    3  Pages

  34. CVM-A Series

    7  Pages

  35. URBAN

    2  Pages

  36. RAPTION 150

    2  Pages

  37. EC-A

    5  Pages

  38. EC-V

    5  Pages

  39. WMC-WTC

    5  Pages

  40. FMZ-FTZ

    3  Pages

  41. SMC-STC

    3  Pages

  42. UC Series

    3  Pages

  43. SYNCHROMAX

    3  Pages

  44. MEG

    2  Pages

  45. C-convert

    9  Pages

  46. TSR

    1  Page

  47. AR5L

    9  Pages

  48. C80

    4  Pages

  49. WGBU

    3  Pages

  50. WI

    2  Pages

  51. CR Series

    1  Page

  52. LR-LRB

    3  Pages

  53. computer MAX

    2  Pages

  54. CV

    2  Pages

  55. CLZ-FP-HD

    5  Pages

  56. R-RE-RBE

    2  Pages

  57. LVC

    1  Page

  58. RGU10

    2  Pages

  59. WGC series

    2  Pages

  60. RGE

    2  Pages

  61. RG1M

    2  Pages

  62. CSB

    2  Pages

  63. MCB

    2  Pages

  64. TSA

    2  Pages

  65. Short-Form 2021

    162  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.