Catalog excerpts
PRIME Solutions for AMI systems Technology for energy efficiency
Open the catalog to page 1Telemanagement Most utility distribution companies have developed and implemented modernisation plans for their distribution lines, with the aim of improving energy efficiency. In some countries, these improvements are prompted by regulations that make it compulsory to provide a more intelligent network, covering such areas as power generation control, improvements to the distribution lines, remote metering and remote control of transformer substations or the installation of smart meters. A whole range of new possibilities has emerged in the area of smart metering that were completely...
Open the catalog to page 2Telemanagement system Benefits of the system 1. Billing process The telemanagement system with PRIME PLC communications enables the meter reading process to be controlled automatically, thus eliminating reading errors and reducing the costs associated with managing meters. 2. Demand management From the information received from the meters, the concentrator allows you to create an accurate prediction of the energy demand in different time slots. This facilitates the management of the generation capacity of power distribution companies. 3. Technical management To facilitate the technical...
Open the catalog to page 3Compact concentrator for telemanagement Concentrator COMPACT DC Serie Purpose of a PLC concentrator The main purpose of a PLC concentrator is to read the energy meters over the electrical network and export that data to one or more computer systems that are responsible for managing concentrators or, failing that, meters. The ability to send the same data collected by the concentrator to different systems results in faster billing, for example, as the measurements are obtained instantly. Not only power distribution companies and operators of distribution lines can optimise their procedures....
Open the catalog to page 4Functionalities and features of COMPACT DC The COMPACT DC concentrator is normally installed in the transformer substation, by mounting it on a DIN rail and connecting it to the low voltage winding of the three-phase system. This allows the meters to be remotely managed through PLC communications, using the protocol standardised by PRIME Alliance. All of the information recorded by the meters is obtained using PLC. This information includes the load profiles, daily or monthly summaries of consumption and even quality parameters and any events that have occurred at the measuring point. As...
Open the catalog to page 5PLC Communications In terms of PLC communications, the concentrator has a passive three-phase injection system, that injects the maximum power permitted by standard EN 50065, by all 3 phases at once. In addition to the three-phase injection, the concentrator can be configured, via the web, to inject through one of the 3 phases. This is used in cases where one of the phases interferes with the communications of the other phases. Models The PRIME COMPACT DC range of concentrators is available in different models, depending on the needs of each installation. The most basic model is the COMPACT...
Open the catalog to page 6Technical features Power supply circuit Rated voltage Compact DC Basic 10... 26 VA Compact DC 2 Installation category Communications port 1x Ethernet 10/100 Mbit, insulated 10 kV for 1 minute Operating system LV Supervision system Rated voltage Frequency Installation category Frequency measurement margin Active energy measurement Reactive energy measurement Impulse LEDs 1 impulse LED for active energy: 20000 imp/kWh 1 impulse LED for reactive energy: 20000 imp/kVArh Quad band HSPA + HSPA/UMTS 850/900/1900/2100 MHz Maximum output power Mini-SIM with dual bay Antenna Digital inputs (Compact...
Open the catalog to page 7Energy meters for residential applications residential meters B200RCP / B410RCP Type 5 meters Residential meters make up the bulk of the systems that have to be controlled by power distribution companies. The PRIME system provides a more effective solution for the telemanagement of this kind of meter. 8 PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.c
Open the catalog to page 8Applications CIRCUTOR has developed both the single-phase and three-phase meter with PRIME communications, for residential power supplies below 15 kW. The main features of these types of systems are as follows: –– Measurement of active and reactive energy, with the ability to distinguish between energy consumed and generated (4 quadrants). –– It remotely collects information about energy consumption, eliminating the errors associated with manual readings and eradicating the need to make estimates. –– Inclusion of a circuit breaker with two main functions. Thanks to the first function, the...
Open the catalog to page 9Energy meters for industrial applications and SMEs industrial meters B410DP / B410TP Type 3 and 4 meters This PRIME telemanagement system provided by CIRCUTOR not only offers a robust solution for residential meter management, it also enables the integration of industrial direct and indirect measurement meters for low voltage supplies above 15 kW. 10 PRIME © 2016 CIRCUTOR, SA — circutor.com — central@circutor.c
Open the catalog to page 10Applications Although telemanagement systems were originally created to deliver effective reading and management of residential meters, it is to be expected that during the second phase, or even in the initial project, one of the objectives set was to take advantage of all of the resources that had already been deployed to integrate the industrial meters connected to the same low voltage network. CIRCUTOR has integrated PRIME communications into the direct and indirect measurement three-phase energy meters. By including these customers, complete telemanagement of all supplies connected to a...
Open the catalog to page 11Accessories for the telemanagement system System accessories CIRCUTOR has a complete range of accessories, ranging from the current transformers used in industrial indirect measurement meters, overvoltage protection that optimises the service life of our equipment, protecting it against electrical disturbances, components with 3G modems that allow our concentrators to be integrated into communications networks, the SoftWatt PRIME parameterisation software which can be used to configure meters and the optical head for local reading and downloading from the units. SoftWatt SoftWatt PRIME...
Open the catalog to page 12All CIRCUTOR catalogs and technical brochures
-
Filtering solutions
16 Pages
-
BC48 15V
4 Pages
-
DCB, Digital instruments
2 Pages
-
WRU-10, Smart protection
2 Pages
-
REC4, Self-reclosing RCCB
8 Pages
-
Electric Vehicle Charging
8 Pages
-
Solutions for ISO 50001
12 Pages
-
TCP2RS+
4 Pages
-
LM4I4O-M
4 Pages
-
Solar photovoltaic canopies
8 Pages
-
Solutions for Self-consumption
16 Pages
-
MYeBOX Connected to efficiency
12 Pages
Archived catalogs
-
Short-Form 2021
162 Pages
-
CSB
2 Pages
-
RG1M
2 Pages
-
RGE
2 Pages
-
WGC series
2 Pages
-
RGU10
2 Pages
-
LVC
1 Pages
-
TSA
2 Pages
-
R-RE-RBE
2 Pages
-
CLZ-FP-HD
5 Pages
-
CV
2 Pages
-
computer MAX
2 Pages
-
LR-LRB
3 Pages
-
CR Series
1 Pages
-
WI
2 Pages
-
MCB
2 Pages
-
WGBU
3 Pages
-
C80
4 Pages
-
AR5L
9 Pages
-
TSR
1 Pages
-
C-convert
9 Pages
-
MEG
2 Pages
-
SYNCHROMAX
3 Pages
-
UC Series
3 Pages
-
SMC-STC
3 Pages
-
FMZ-FTZ
3 Pages
-
WMC-WTC
5 Pages
-
EC-V
5 Pages
-
EC-A
5 Pages
-
RAPTION 150
2 Pages
-
URBAN
2 Pages
-
CVM-A Series
7 Pages
-
BM-V
3 Pages
-
PGR Series
2 Pages
-
SGE-PLC Series
2 Pages
-
LM4I/4O-M
2 Pages
-
RGU-10B
2 Pages
-
CEM-C20
2 Pages
-
CEM-C10
2 Pages
-
OPTIM-HYB
2 Pages
-
RVE2-P
2 Pages
-
cSMARTIII
2 Pages
-
AR6
2 Pages
-
CVM-C5
2 Pages
-
FRE
2 Pages
-
MT-FDE
2 Pages
-
RECmaxMP
2 Pages
-
RECmaxLPD
2 Pages
-
CBS4
2 Pages
-
RGU2
2 Pages
-
CIRWATT-B100
2 Pages
-
FEMC-FETC
3 Pages
-
HC
2 Pages
-
BC-V
3 Pages
-
BC-A
3 Pages
-
TL-5
1 Pages
-
CIRWATT-B505
2 Pages
-
CIRWATT B 502
2 Pages
-
CVM Power analyzers
40 Pages
-
Type B
8 Pages
-
C-FLEX Series
4 Pages
-
MS
1 Pages
-
FLEX-R
1 Pages
-
CIRWATT B 410T
3 Pages
-
TRMC
2 Pages
-
RS2RS
1 Pages
-
ReadWatt
2 Pages
-
Módem Router 3G
2 Pages
-
DIR2
1 Pages
-
computer Smart
2 Pages
-
Smart earth leakage protection
32 Pages
-
ANALOGUE INSTRUMENTS
64 Pages
-
DIGITAL INSTRUMENTS
34 Pages