Smart earth leakage protection

Smart earth leakage protection
1 / 32 PagesView full catalog

Smart earth leakage protection

Product catalog summary
Introduction
The document focuses on smart earth leakage protection systems, highlighting their role in ensuring both protection and continuity of electrical power supply to enhance user safety and prevent unnecessary tripping due to electrical distortions.
Specifications and Features
The systems offer advanced features including True Root Mean Square (TRMS) monitoring, high-frequency filtering, inverse curve delay, adjustable nominal sensitivity triggers, and fault current display for monitoring.
Components of Earth Leakage Protection System
The system consists of three main components: a detecting element or sensor, a relay, and a circuit breaker, each playing a crucial role in detecting and interrupting earth leakage currents.
Types of Loads
Loads are categorized based on their insulation from earth, including those with no earthed capacitors and those with earthed capacitors, which can cause capacitive earthing faults.
Immunised Earth Leakage Protection
Advancements in immunised protection systems address issues like transient leakages and high-frequency currents, with features such as TRMS measurement, immunity to transient leakages, and adjustable triggers.
Standards and Compliance
The document references IEC 61008-1 standards, emphasizing the importance of immunity against transient leakages to maintain electrical supply continuity.
Monitoring and Maintenance
Continuous monitoring of leakage currents is essential for preventive and corrective maintenance, allowing timely interventions to prevent system triggers.
Conclusion
The integration of earth leakage currents into energy control systems is emphasized for enhanced monitoring and control.
Overview of Self-Reclosing Systems
The document provides a guide on industrial earth leakage protection systems, focusing on self-reclosing systems, their components, and operational parameters, highlighting the importance of continuous energy supply and remote control capabilities.
Key Sections
1. Earth Leakage Protection Systems
These systems are crucial for installations requiring uninterrupted energy supply, including remote control and reset functions.
2. Self-Reclosing Systems
Designed for installations needing constant energy supply, these systems ensure safety and service continuity.
3. Components of Self-Reclosing Systems
Includes earth leakage transformers, self-reclosing relays, and circuit breakers, each with specific roles and features.
4. Parameters of Self-Reclosing Relays
Include relay status indicators, nominal trigger points, and timer settings to ensure effective operation.
5. Earth Leakage Transformers (WGC Series)
Offer improved installation options and greater immunity to transient current peaks.
6. Electronic Earth Leakage Relays
Details various models with features like protection class, measurement methods, and compatibility with external transformers.
Conclusion
Emphasizes the importance of selecting appropriate earth leakage protection systems and components for safety and reliability.
Device Specifications and Features
Details technical specifications and features of various earth leakage protection devices, including relays and transformers, designed for industrial applications.
Applications
These devices are used for intelligent earth leakage protection in industrial settings, ensuring maximum security and continuity of electrical services.
WRN-22 Earth Leakage Protection
Designed for small-scale installations, offering efficient detection of earth leakage in compact environments.
Manufacturer Information
CIRCUTOR, SA, located in Viladecavalls, Barcelona, Spain, is the manufacturer of the WRN-22, providing reliable safety measures for electrical installations.
See more

Catalog excerpts

Smart earth leakage protection-1

Smart earth leakage protection

 Open the catalog to page 1
Smart earth leakage protection-2

Smart earth leakage protection Contenido WGC Earth leakage transformres WGC Series · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · P1-13 WG WG Series Earth Leakage transformers· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · P1-14 RG1M Electronic earth leakage relay with external transformer of the WG / WGC Series · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · P1-15 RGE...

 Open the catalog to page 2
Smart earth leakage protection-3

Industrial earth leakage protection Smart earth leakage protection The "protection" and "continuity" of the electrical power supply are two terms that must not be separated if we wish to guarantee the safety of users and electrical installations. The recent addition of receivers or loads that generate distortion in the electricity grid (speed variators, electronic startup units, computer equipment, lighting with electronic ballasts, etc.) has made necessary the use of protection systems that can distinguish between defects in the installation and the electrical alterations that cause the unwanted...

 Open the catalog to page 3
Smart earth leakage protection-4

Industrial earth leakage protection Definition When the earth leakage protection system detects a fault current, it acts on the electrical installation being protected, opening the circuit while interrupting the supply of electrical energy, thus preventing the danger of electrocution for persons when the fault current reaches dangerous values, either as a result of direct or indirect contact, including any potential damage caused to goods and materials. An earth leakage protection system is composed of three clearly different parts: }} Detecting element or sensor }} Relay }} Circuit breaker ceived...

 Open the catalog to page 4
Smart earth leakage protection-5

Industrial earth leakage protection In this case, we must simply adjust the sensitivity and delay time to guarantee the adequate protection. Loads with earthed capacitors The current passes through the earthing elements as a result of the unit's operations through its capacitors. In addition, the length of cables in an electrical installation can lead to capacitive earthing faults, which would lead to this situation. The current can be injected with two methods: Permanent Leakages. The unit injects current in the earthing elements permanently. This type of behaviour is closely tied to the use...

 Open the catalog to page 5
Smart earth leakage protection-6

Industrial earth leakage protection Measurement in TRMS and Class A The voltage and current wave shapes have stopped being complete sine waves since the loads distributed in the installations are not linear. The continuous and harmonic components can distort the wave shapes, whereby it will be necessary to take more accurate measurements. CLASS AC The earth leakage devices used in domestic installations or that protect loads that do not cause distortions can be of the AC Type. These devices are marked with a symbol, in compliance with the IEC 61008-1 Standard. The current range of electronic...

 Open the catalog to page 6
Smart earth leakage protection-7

Industrial earth leakage protection The IEC 479-1 / UNE 20-572-92 Standard describes the effects of currents passing through the human body for a frequency of 50 Hz. As you can see, the effect depends on the root-meansquare-value of the current passing through the body and the time it takes to pass through. In accordance with the effects, we can establish zones 1 (zone with no perception) and 2 (perception zone) as safe work zones. Therefore, in terms of the protection of persons, earth leakage protection systems must act on those zones. previous graph, which indicates that the current is less...

 Open the catalog to page 7
Smart earth leakage protection-8

Industrial earth leakage protection Inverse curve The IEC 61008-1 Standard allows us to incorporate a circuit opening delay for the circuit being protected, which will depend on the leakage current level. Therefore, the greater the fault current, the lower the delay. }} Instantaneous }} Selective Two types of curves are specified, as shown on the following table of values: t Standardised operating time values (s) The application of these curves to our earth leakage systems can be used to increase the continuity in the installation's power supply and avoid unwanted trips. Monitoring protection...

 Open the catalog to page 8
Smart earth leakage protection-9

Industrial earth leakage protection Earth leakage protection systems with self-reclosing Given the current efficient personal and material protection requirements and obligations, and the complexity of some installations that require the continuous supply of electrical energy with the use of overload and earth leakage protection systems, CIRCUTOR has developed a wide range of units that make safety and service continuity compatible. Self-reclosing systems are an ideal solution for installations that need a constant supply of electrical energy, without the need for the usual maintenance staff:...

 Open the catalog to page 9

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4  Pages

  2. TCP2RS+

    4  Pages

  3. LM4I4O-M

    4  Pages

Archived catalogs

  1. DIR2

    1  Page

  2. ReadWatt

    2  Pages

  3. RS2RS

    1  Page

  4. FLEX-R

    1  Page

  5. MS

    1  Page

  6. C-FLEX Series

    4  Pages

  7. Type B

    8  Pages

  8. CIRWATT B 502

    2  Pages

  9. CIRWATT-B505

    2  Pages

  10. TL-5

    1  Page

  11. BC-A

    3  Pages

  12. BC-V

    3  Pages

  13. HC

    2  Pages

  14. FEMC-FETC

    3  Pages

  15. CIRWATT-B100

    2  Pages

  16. RGU2

    2  Pages

  17. CBS4

    2  Pages

  18. RECmaxLPD

    2  Pages

  19. RECmaxMP

    2  Pages

  20. MT-FDE

    2  Pages

  21. FRE

    2  Pages

  22. CVM-C5

    2  Pages

  23. AR6

    2  Pages

  24. cSMARTIII

    2  Pages

  25. RVE2-P

    2  Pages

  26. OPTIM-HYB

    2  Pages

  27. CEM-C10

    2  Pages

  28. CEM-C20

    2  Pages

  29. RGU-10B

    2  Pages

  30. LM4I/4O-M

    2  Pages

  31. TRMC

    2  Pages

  32. PGR Series

    2  Pages

  33. BM-V

    3  Pages

  34. CVM-A Series

    7  Pages

  35. URBAN

    2  Pages

  36. RAPTION 150

    2  Pages

  37. EC-A

    5  Pages

  38. EC-V

    5  Pages

  39. WMC-WTC

    5  Pages

  40. FMZ-FTZ

    3  Pages

  41. SMC-STC

    3  Pages

  42. UC Series

    3  Pages

  43. SYNCHROMAX

    3  Pages

  44. MEG

    2  Pages

  45. C-convert

    9  Pages

  46. TSR

    1  Page

  47. AR5L

    9  Pages

  48. C80

    4  Pages

  49. WGBU

    3  Pages

  50. WI

    2  Pages

  51. CR Series

    1  Page

  52. LR-LRB

    3  Pages

  53. computer MAX

    2  Pages

  54. CV

    2  Pages

  55. CLZ-FP-HD

    5  Pages

  56. R-RE-RBE

    2  Pages

  57. LVC

    1  Page

  58. RGU10

    2  Pages

  59. WGC series

    2  Pages

  60. RGE

    2  Pages

  61. RG1M

    2  Pages

  62. CSB

    2  Pages

  63. MCB

    2  Pages

  64. TSA

    2  Pages

  65. Short-Form 2021

    162  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.