video corpo

RGU10

RGU10

RGU10

Product catalog summary
Overview
The RGU-10 is a smart earth leakage protection relay designed for use with external transformers from the WG series. It features high-frequency current filtering and high immunity, with true RMS measurement capabilities. The relay includes a display for data visualization and two independent programmable outputs for main and prealarm functions. It also supports remote control functions via a 230 Vac external input.
Applications
The RGU-10 relays, when used with WG transformers, provide intelligent earth leakage protection, ensuring maximum security and continuity of electrical service by preventing unwanted tripping. The display of instantaneous leakage values and prealarm indicators aids in line status monitoring and preventive maintenance. The RGU-10 C version offers RS-485 communications for centralized real-time supervision and historical data logging with PowerStudio software.
Technical Features
  • Compatibility: WGC earth leakage transformers
  • Protection: Class A super-immunized
  • Measurement: True root mean square (TRMS)
  • Sensitivity: 0.03 to 3 A, 0.03 to 30 A (programmable)
  • Delay: 0.02 to 10 s, with instantaneous or selective inverse curve
  • Test and Reset: Built-in buttons, T & R
  • Remote Control: External test option
  • Associated Circuit Breaker: Contactor or circuit breaker with trigger coil
  • LED Indicators: Power supply voltage, leakage trip, disconnection of external transformer, prealarm
  • Display: Trip current, parameter programming, instantaneous leakage current, disconnection of external transformer
  • Remote Signaling: Prealarm, parameter display via RS-485 communication (RGU-10 C)
  • Circuit Breaker Control: Via NO/NC switched relay
Electrical Features
  • Auxiliary Power Supply: 230 Vac (± 20%) 50/60 Hz
  • Output Contacts: 250 Vac, 6 A
  • Operating Temperature: -10 ºC to +50 ºC
Mechanical Features
  • Attachment: DIN 46277 rail (EN 50022)
  • Dimensions: 3 modules
  • Weight: 236 g
  • Protection Degree: IP 20 on terminals, IP 41 on back panel
Standards
Complies with IEC 60947-2, IEC 60755, IEC 61008, IEC 62020.
References
  • RGU-10: Code P11941, no communications, sensitivity and delay programmable
  • RGU-10C: Code P11944, RS-485 Modbus/RTU communications, sensitivity and delay programmable
See more

Catalog excerpts

RGU10-1

Smart earth leakage protection Electronic earth leakage relay with external transformer of the WG series Description Electronic earth leakage protection relay of the WG series, connected to the external transformers of the WG / WGC series. Superimmunized type relay with high frequency currents filtering and high immunity. True RMS measurement (TRMS). —— Data shown on the display —— Features two independent programmable outputs (main and prealarm) —— External input for remote-control functions (230 Vac) Applications The RGU-10 relays associated with WG transformers offer smart earth leakage protection. Their design features guarantee maximum security and electrical service continuity, avoiding unwanted tripping. Compatible with WGC earth leakage transformers Viewing the instantaneous leakage value on the display, together with the prealarm indicators, makes it possible to obtain information on the status of lines to be protected, and to perform adequate preventive maintenance. In addition, version RGU-10 C features RS-485 communications and, with the PowerStudio software, offers centralised supervision in real time, as well as keeping a log of historical data for future analysis. Technical features Protection Time defined: 0.02...10 s Inverse curve: Instantaneous or selective Earth leakage transformer With built-in buttons, T & R Remote control External test option Associated circuit breaker Contactor or circuit breaker + trigger coil Power supply voltage Leakage trip Disconnection of external transformer Prealarm Trip current (red display when tripped) Parameter programming Instantaneous leakage current Disconnection of external transformer Remote signaling Prealarm Display of parameters via RS-485 communication (RGU-10 C) Circuit breaker control Via an NO/NC switched relay, depending on the connection with the circuit breaker Auxiliary power supply 230 Vac (± 20%) 50 / 60 Hz (other values on demand) Output contacts Operating temperature Protection degree Standards True root mean square (TRMS) Mechanical features Electrical features IP 20 on terminals, IP 41 on back panel

 Open the catalog to page 1
RGU10-2

Smart earth leakage protection Electronic earth leakage relay with external transformer of the WG series References Type Connections Shunt coil Undervoltage coil

 Open the catalog to page 2

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4  Pages

  2. TCP2RS+

    4  Pages

  3. LM4I4O-M

    4  Pages

Archived catalogs

  1. DIR2

    1  Page

  2. ReadWatt

    2  Pages

  3. RS2RS

    1  Page

  4. FLEX-R

    1  Page

  5. MS

    1  Page

  6. C-FLEX Series

    4  Pages

  7. Type B

    8  Pages

  8. CIRWATT B 502

    2  Pages

  9. CIRWATT-B505

    2  Pages

  10. TL-5

    1  Page

  11. BC-A

    3  Pages

  12. BC-V

    3  Pages

  13. HC

    2  Pages

  14. FEMC-FETC

    3  Pages

  15. CIRWATT-B100

    2  Pages

  16. RGU2

    2  Pages

  17. CBS4

    2  Pages

  18. RECmaxLPD

    2  Pages

  19. RECmaxMP

    2  Pages

  20. MT-FDE

    2  Pages

  21. FRE

    2  Pages

  22. CVM-C5

    2  Pages

  23. AR6

    2  Pages

  24. cSMARTIII

    2  Pages

  25. RVE2-P

    2  Pages

  26. OPTIM-HYB

    2  Pages

  27. CEM-C10

    2  Pages

  28. CEM-C20

    2  Pages

  29. RGU-10B

    2  Pages

  30. LM4I/4O-M

    2  Pages

  31. TRMC

    2  Pages

  32. PGR Series

    2  Pages

  33. BM-V

    3  Pages

  34. CVM-A Series

    7  Pages

  35. URBAN

    2  Pages

  36. RAPTION 150

    2  Pages

  37. EC-A

    5  Pages

  38. EC-V

    5  Pages

  39. WMC-WTC

    5  Pages

  40. FMZ-FTZ

    3  Pages

  41. SMC-STC

    3  Pages

  42. UC Series

    3  Pages

  43. SYNCHROMAX

    3  Pages

  44. MEG

    2  Pages

  45. C-convert

    9  Pages

  46. TSR

    1  Page

  47. AR5L

    9  Pages

  48. C80

    4  Pages

  49. WGBU

    3  Pages

  50. WI

    2  Pages

  51. CR Series

    1  Page

  52. LR-LRB

    3  Pages

  53. computer MAX

    2  Pages

  54. CV

    2  Pages

  55. CLZ-FP-HD

    5  Pages

  56. R-RE-RBE

    2  Pages

  57. LVC

    1  Page

  58. WGC series

    2  Pages

  59. RGE

    2  Pages

  60. RG1M

    2  Pages

  61. CSB

    2  Pages

  62. MCB

    2  Pages

  63. TSA

    2  Pages

  64. Short-Form 2021

    162  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.