Technical features Service continuity guarantee Earth leakage protection Type A (IEC 60755) Ultra-immunised True root mean square value (TRMS) Adjustable, 0.03-0.1-0.3-0.5-1 A* Adjustable, Trip curve: INS, SEL Defined time: 0.1 - 0.2 - 0.3 0.4 - 0.5 - 0.6 - 0.8 - 1s Through the use of T and R buttons Type Measurement Sensitivity Trip delay Plug and Play Circuit breaker protection Saves space Earth leakage reclosing / Circuit breaker Preventive control of leakages Test and reset Sensor element that can be associated Built-in element Current intensity Number of poles Rated voltage, Un Vac Trip curves Cut off power No. of reclosings Time between reclosings WGC earth leakage transformer (inc.) Motorized circuit breaker In 6-10-16-20-25-32-40-50-63 A 2/4 240 / 415 C/D 6 kA Programmable 10 / 2 (by default) Configurable, 3 min. (by default) According to configured sequence, 30 min. (by default) 300 Vac p-n – 520 Vac p-p 50...60 Hz RESET time Measurement circuit Electrical parameter control Accuracy Class Communications systems Industry Communications External inputs Electrical features Mechanical features Voltage Frequency Sensor element that can be associated Transformation ratio of the sensor element V, A, Power Active energy Reactive energy Protocol Speed Bit, parity, stop EXT ON/OFF RECmax CVM Circuit breaker and reclosing earth leakage protection, with measurement included 0.50% I < 0.1 In (Class 1) I > 0.1 In (Class 0.5) Class 2 Modbus/RTU (RS-485) 9600, 19200 8, n, 1 Trip / Rearm, voltage-free input External locking of reclosings, EXT Locked voltage-free input Interlocking output contact Potential-free, 230 Vac, Imax=100 mA Positive safety contact Potential-free, 230 Vac, Imax=100 mA Circuit breaker status contact Potential-free, 230 Vac, Imax=500 mA Digital outputs 24 Vdc – 50 mA Operating temperature -10 ... +55 ºC Attachment DIN rail 46277 (EN 50022) Dimensions 2P: 5.5 modules / 4P: 7.5 modules Weight 2 poles: 539 g / 4 poles: 790 g Protection degree Terminals IP 20, embedded relay IP 41 IEC 60898, IEC 60947-2, IEC 60755, IEC 61557-12 Protects Measures Recloses CIRCUTOR, SA - Vial Sant Jordi, s/n 08232 Viladecavalls (Barcelona) Spain Tel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 [email protected] Information systems, UPS systems C2P283-01 CIRCUTOR, SA reserves the right to change any information contained in this catalogue. Technology for energy efficien
Open the catalog to page 1Saves time and space Circuit breaker and reclosing earth leakage protection, with measurement included Your installation controlled on a single device 4 Poles > The Plug&Play system simplifies the installation in an easy and intuitive way. > Sensors with cable outlet and terminal block, simply connect and start them (included). > Integrated voltage power supply (selfpowered), simplifying the installation. Avoids unwanted tripping > Protection:circuit breaker and ultraimmunised earth leakage protection. > Avoids unnecessary tripping due to harmonics. Information at your fingertips The display...
Open the catalog to page 22 Pages
4 Pages
2 Pages
8 Pages
8 Pages
20 Pages
12 Pages
4 Pages
4 Pages
8 Pages
16 Pages
12 Pages
34 Pages
32 Pages
64 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
4 Pages
8 Pages
3 Pages
2 Pages
2 Pages
1 Page
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
7 Pages
2 Pages
2 Pages
5 Pages
5 Pages
5 Pages
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
9 Pages
1 Page
9 Pages
4 Pages
3 Pages
2 Pages
1 Page
3 Pages
2 Pages
2 Pages
5 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
40 Pages
2 Pages
2 Pages
162 Pages