1. Catalogs
  2. CIRCUTOR
  3. Protection relays and transformers
video corpo

Protection relays and transformers

Protection relays and transformers
1 / 18 PagesView full catalog

Protection relays and transformers

Product catalog summary
Introduction
This document provides an overview of protection relays and transformers, focusing on their applications, specifications, and selection criteria. It highlights the range of products offered by CIRCUTOR, designed to meet various client needs and comply with relevant specifications.
Product Selection Table
The document includes a product selection table categorizing equipment based on applications such as beacon control equipment, harmonics relays, current relays, and transformer overload protection relays.
Control Relays
Beacon Control Relays (TB and TB-3): These relays supervise and control beacon circuits on telephony transmission towers, managing ballast consumption and photocell inputs. The TB model handles dual circuits, while the TB-3 model is for single circuits.
Voltage Detector Control Relay (RV-M / RV-T / RV-TS): These relays protect against disruptions in the neutral connection by measuring voltages between phases, applicable to both single-phase and three-phase installations.
Protection Transformers
Types and Features: The document describes TRM (Measurement Transformers) and TRP (Protection Transformers), both encapsulated in resin for robustness and core manipulation prevention. Key features include primary and secondary current specifications, frequency, insulation voltage, and thermal class.
Selection Criteria: Choosing the right transformer involves understanding the application, environmental conditions, line features, and associated instrument specifications. The transformer's power is crucial to meet line losses and equipment consumption.
Standards and Compliance
The products comply with standards such as IEC 60044-1 and UNE-EN 60044-1, ensuring reliability and safety in their applications.
Conclusion
CIRCUTOR offers a comprehensive range of protection relays and transformers designed for various applications, ensuring robust performance and compliance with industry standards.
Voltage Monitoring Relays
These relays detect incorrect phase sequence, phase loss, voltage surges, and drops, suitable for industrial and modular cabinets using true root mean square measurement. Protection against voltage surges triggers at voltages higher than 265 V, while voltage drops trigger at less than 160 V. Phase sequence errors have a fixed trigger time of 1 s, except for the RV-TS type. External input activation has a trigger time of ≤10 ms, with indication LEDs for power supply and voltage error.
Control Relays
Applicable for single-phase and three-phase installations with different types and codes for each configuration. Specifications include a power supply circuit of 230 Vac, frequency of 50 Hz, and various testing voltages. Build features include DIN rail fixing, dimensions of 4 modules, weight of 250 g, and an operating temperature range of 0 to +50 ºC. Standards compliance includes IEC, EN, UL, UNE, and VDE standards.
Current Detector Control Relay (WI)
Used for applications needing load control such as grinders, extrusion machines, and motors. Features include adjustable trip levels, automatic reset, and adjustable connection/disconnection times. Measurement options with built-in or separate transformers.
Harmonics Detector Control Relay (WDH)
Used to protect transformers and capacitor banks from harmonic overloads. Monitors and acts based on the true root mean square of harmonic current with adjustable trigger levels and delay times. Automatic reset with currents under 10% of the trip level.
Current Relay Station (CDR-8)
Measures and controls current for up to 8 lines, configurable as earth leakage or current relay. Displays current and status on an LCD, with programmable thresholds and delays. Includes features for automatic reclosing and remote signaling through RS-485.
See more

Catalog excerpts

Protection relays and transformers-1

Protection relays and transformers

 Open the catalog to page 1
Protection relays and transformers-2

Protection relays and transformers Introduction · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 3 Product selection table· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 6 Beacon control relays · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·...

 Open the catalog to page 2
Protection relays and transformers-3

Protection relays and transformers Protection relays and transformers CIRCUTOR offers a range of protection relays for different and specific applications. Many of these products have been designed in compliance with the corresponding specifications, always catering for the needs of our clients. Our range of products includes simple relays that are very easy to use, such as current relays, or even protection relays used to assemble cells in substations. We can highlight the following applications in this section: }} Beacon control relays }} Current control relays }} Harmonics relays }} Overload...

 Open the catalog to page 3
Protection relays and transformers-4

Protection relays and transformers Protection transformers Selection table of the type of transformer, in accordance with the list of transformers between the nominal current of the primary (Ip) and secondary (Is) 5 000/5 4 000/5 - There are two types of transformers: }} TRM: Measurement transformers en- CIRCUTOR offers a complete range of current transformers encapsulated in resin. One of the advantages of this type of transformers is that they increase the degree of robustness (high mechanical resistance, high electrical rigidity, tropicalization, etc.). In addition, this range fully prevents...

 Open the catalog to page 4
Protection relays and transformers-5

Protection relays and transformers the measurement unit. Induced power must be equal to or more than the line losses plus the power consumed by the measurement equipment. in measurement transformers and at 100% of the nominal power. In the case of protection transformers, only at 100% of the nominal power. The transformer's response to saturation Power losses due to the transmission of current through the cabling resistor RL of the secondary cabling circuit of the transformer. Factors that must be taken into account: }} Secondary current. PL = RL • I 2 }} Cable diameter. RL is inversely pro-...

 Open the catalog to page 5
Protection relays and transformers-6

Protection relays and transformers Beacon control equipment Beacon control equipment Harmonics relay Current relay Earth leakage current station Transformer overload protection relays Protection and measurement transformer Product selection table Measurement transformers

 Open the catalog to page 6
Protection relays and transformers-7

Control relays Beacon control relays Description The TB type Beacon control system is in charge of the supervision, control and indication of anomalies detected in the different Beacon components of the telephony transmission towers. TB / TB-55 Features: }} Control and measurement of the consumption of the two sets of independent ballasts(230 Vac power supply): the main circuit and the reserve circuit. The reserve circuit is connected when there is a fault in the main circuit or when a lamp goes out. }} Control inputs of the two twilight photocells on the tower. When the light level is under...

 Open the catalog to page 7
Protection relays and transformers-8

Control relays Beacon control relays POWER SUPPLY TEST TEST

 Open the catalog to page 8
Protection relays and transformers-9

Control relays Beacon control relays Description The TB-3 type Beacon control system is in charge of the supervision, control and transmission of anomalies detected in the different Beacon components of the telephony transmission towers. TB-3 Features: }} Start-up control and measurement of the consumption of a single Beacon circuit: group of 1, 2 or 3 75W/230V or 15W/230Vac lamps. }} Inputs for a twilight photocell. The photocell will be supplied with the unit and is connected with the corresponding terminals (+ and - inputs of the photocell). }} Adjustments of the TB-3 yy Power of the 15 to...

 Open the catalog to page 9
Protection relays and transformers-10

Control relays Beacon control relays BLACK WIRE ALARIIA FOTOCfiJJLA

 Open the catalog to page 10
Protection relays and transformers-11

Control relays RV-M / RV-T / RV-TS Voltage detector control relay Description Electronic relay for protection and continuous voltage monitoring. yy Protection against voltage surges, triggers at voltages higher than 265 V. Trigger time according to the voltage value less than or equal to: yy 300 V triggers after 3 s yy 350 V triggers after 800 ms yy 400 V triggers after 200 ms yy Protection against voltage drop, triggers at voltages less than 160 V. Fixed trigger time of 300 ms. yy Error in phase sequence (incorrect phase connection order for RV-T. Fixed trigger time 1 s. yy The RV-TS type does...

 Open the catalog to page 11

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4  Pages

  2. TCP2RS+

    4  Pages

  3. LM4I4O-M

    4  Pages

Archived catalogs

  1. DIR2

    1  Page

  2. ReadWatt

    2  Pages

  3. RS2RS

    1  Page

  4. FLEX-R

    1  Page

  5. MS

    1  Page

  6. C-FLEX Series

    4  Pages

  7. Type B

    8  Pages

  8. CIRWATT B 502

    2  Pages

  9. CIRWATT-B505

    2  Pages

  10. TL-5

    1  Page

  11. BC-A

    3  Pages

  12. BC-V

    3  Pages

  13. HC

    2  Pages

  14. FEMC-FETC

    3  Pages

  15. CIRWATT-B100

    2  Pages

  16. RGU2

    2  Pages

  17. CBS4

    2  Pages

  18. RECmaxLPD

    2  Pages

  19. RECmaxMP

    2  Pages

  20. MT-FDE

    2  Pages

  21. FRE

    2  Pages

  22. CVM-C5

    2  Pages

  23. AR6

    2  Pages

  24. cSMARTIII

    2  Pages

  25. RVE2-P

    2  Pages

  26. OPTIM-HYB

    2  Pages

  27. CEM-C10

    2  Pages

  28. CEM-C20

    2  Pages

  29. RGU-10B

    2  Pages

  30. LM4I/4O-M

    2  Pages

  31. TRMC

    2  Pages

  32. PGR Series

    2  Pages

  33. BM-V

    3  Pages

  34. CVM-A Series

    7  Pages

  35. URBAN

    2  Pages

  36. RAPTION 150

    2  Pages

  37. EC-A

    5  Pages

  38. EC-V

    5  Pages

  39. WMC-WTC

    5  Pages

  40. FMZ-FTZ

    3  Pages

  41. SMC-STC

    3  Pages

  42. UC Series

    3  Pages

  43. SYNCHROMAX

    3  Pages

  44. MEG

    2  Pages

  45. C-convert

    9  Pages

  46. TSR

    1  Page

  47. AR5L

    9  Pages

  48. C80

    4  Pages

  49. WGBU

    3  Pages

  50. WI

    2  Pages

  51. CR Series

    1  Page

  52. LR-LRB

    3  Pages

  53. computer MAX

    2  Pages

  54. CV

    2  Pages

  55. CLZ-FP-HD

    5  Pages

  56. R-RE-RBE

    2  Pages

  57. LVC

    1  Page

  58. RGU10

    2  Pages

  59. WGC series

    2  Pages

  60. RGE

    2  Pages

  61. RG1M

    2  Pages

  62. CSB

    2  Pages

  63. MCB

    2  Pages

  64. TSA

    2  Pages

  65. Short-Form 2021

    162  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.