video corpo

OPTIM-HYB
2Pages

{{requestButtons}}

Catalog excerpts

OPTIM-HYB - 1

Automatic capacitor banks Automatic hybrid switching capacitor banks Description The OPTIM HYB automatic capacitor banks with hybrid switching are units designed for automatic compensation of reactive energy in networks in which the load levels fluctuate, with power variation rates of seconds and also independently of the level of unbalance in the installation. The compensation system is based on the combination of switching by three-phase step contact breakers and single-phase step semiconductors (thyristors), controlled by a smart regulator that uses the electrical parameters provided via communications by a power analyzer of the CVM-MINI range for its calculations. Application The OPTIM HYB series is ideal for achieving very accurate reactive power compensation in any installation, and especially those that present a certain degree of unbalance, since the compensation between phase and neutral adds to the fast reply provided by the static switching of the thyristor. It is therefore possible to guarantee a significant reduction in the chance of penalties in comparison with conventional capacitor banks. Technical features Electrical features Operating voltage Support voltage Capacity tolerance Contactor switching voltage Semiconductor activation controller board power supply voltage Single-phase capacitor switching Solid state semiconductor Including aluminium heatsink for heat dissipation Three-phase capacitor switching Three-pole contact breakers suitable for capacitive currents, equipped with a preinserted resistor block Cylindrical capacitor, aluminium housing, CLZ-FP type Overload protection Single or three-pole circuit breaker protection on each single or three-phase step Reactive energy regulator Computer HYB communicated via RS-485 with a CVM-MINI power analyzer Main switch Tetra-polar manual switch included as standard Add-ons (optional) Tetra-polar circuit breaker on capacitor bank header Tetrapolar circuit breaker + earth leakage protection on capacitor bank header Polycarbonate plate for protection against direct contacts 400/230 V autotransformer Residual discharge voltage Capacitor losses Permissible overload 1.3 times the nominal hold current 10%, 8 over 24 hours 15%, up to 15 minutes over 24 hours Environmental conditions Mechanical features Enclosure material Steel plate Protection Degree Assembly conditions 20%, up to 5 minutes over 24 hours 30%, up to 1 minute over 24 hours Wall-mounting in OPTIM HYB1 models Free standing assembly in OPTIM HYB2 and OPTIM HYB3 Positioning the unit

Open the catalog to page 1
OPTIM-HYB - 2

Automatic capacitor banks Automatic hybrid switching capacitor banks OPTIM HYB References kvar Manual switch width x height x depth Switch and cable cross-section recommended for installations with Un= 400 V. Installers must confirm that this meets everything established in the Low Voltage Directive according to the special characteristics of each installation and cable type, completely relieving CIRCUTOR S.A. of all breaches of the pertinent regulations as a result of an incorrect choice of the type and cross-section of the cabling.

Open the catalog to page 2

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4 Pages

  2. TCP2RS+

    4 Pages

  3. LM4I4O-M

    4 Pages

Archived catalogs

  1. Short-Form 2021

    162 Pages

  2. CSB

    2 Pages

  3. RG1M

    2 Pages

  4. RGE

    2 Pages

  5. WGC series

    2 Pages

  6. RGU10

    2 Pages

  7. LVC

    1 Pages

  8. TSA

    2 Pages

  9. R-RE-RBE

    2 Pages

  10. CLZ-FP-HD

    5 Pages

  11. CV

    2 Pages

  12. computer MAX

    2 Pages

  13. LR-LRB

    3 Pages

  14. CR Series

    1 Pages

  15. WI

    2 Pages

  16. MCB

    2 Pages

  17. WGBU

    3 Pages

  18. C80

    4 Pages

  19. AR5L

    9 Pages

  20. TSR

    1 Pages

  21. C-convert

    9 Pages

  22. MEG

    2 Pages

  23. SYNCHROMAX

    3 Pages

  24. UC Series

    3 Pages

  25. SMC-STC

    3 Pages

  26. FMZ-FTZ

    3 Pages

  27. WMC-WTC

    5 Pages

  28. EC-V

    5 Pages

  29. EC-A

    5 Pages

  30. RAPTION 150

    2 Pages

  31. URBAN

    2 Pages

  32. CVM-A Series

    7 Pages

  33. BM-V

    3 Pages

  34. PGR Series

    2 Pages

  35. LM4I/4O-M

    2 Pages

  36. RGU-10B

    2 Pages

  37. CEM-C20

    2 Pages

  38. CEM-C10

    2 Pages

  39. RVE2-P

    2 Pages

  40. cSMARTIII

    2 Pages

  41. AR6

    2 Pages

  42. CVM-C5

    2 Pages

  43. FRE

    2 Pages

  44. MT-FDE

    2 Pages

  45. RECmaxMP

    2 Pages

  46. RECmaxLPD

    2 Pages

  47. CBS4

    2 Pages

  48. RGU2

    2 Pages

  49. CIRWATT-B100

    2 Pages

  50. FEMC-FETC

    3 Pages

  51. HC

    2 Pages

  52. BC-V

    3 Pages

  53. BC-A

    3 Pages

  54. TL-5

    1 Pages

  55. CIRWATT-B505

    2 Pages

  56. Type B

    8 Pages

  57. MS

    1 Pages

  58. FLEX-R

    1 Pages

  59. TRMC

    2 Pages

  60. RS2RS

    1 Pages

  61. ReadWatt

    2 Pages

  62. DIR2

    1 Pages