video corpo

MDC 4, New Maximum Demand Control by level
2Pages

{{requestButtons}}

Catalog excerpts

MDC 4, New Maximum Demand Control by level - 1

Main features MDC-4 Basic option Analyzer to control the maximum demand for each level MDC-4 xx Built-in power analyzer. xx Demand management that can control up to 4 local loads. xx Calculations on scrolling window. xx Measurement of electrical parameters of the installation. xx Activation by level above setpoint. xx Programming of the contracted power. xx Programming of 4 different alarm levels for the outputs. xx100…240 Vac power supply. xx Information on load operating time. xx Current measurement with MC transformers. xx Window for displaying power control parameters. xx Compact dimensions. New Maximum Demand Control by level Managing demand 365 days a year MDC-4 is designed to control the maximum demand of an installation for each level. The unit performs analyzer functions and therefore also calculates the energy consumed. Disconnecting non-priority loads at maximum demand times when you are close to the contracted power avoids penalties on your electricity bill. MDC Maximum Demand Controller M61430 www. circutor. com CIRCUTOR, SA - Vial Sant Jordi, s/n 08232 Viladecavalls (Barcelona) Spain Tel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 central@circutor.es Technology for energy efficiency Designed by: communication dept. - CIRCUTOR, SA.

Open the catalog to page 1
MDC 4, New Maximum Demand Control by level - 2

Analyzer to control the maximum demand for each level Level control optimises the installation because it allows the maximum number of loads to be used simultaneously, avoiding any power excesses which would normally result in high penalties. Load management The unit controls the disconnection of up to 4 relays. Loads are disconnected by level. For example, if the unit configuration for each of the relays is as below, the unit's response will be as shown in the attached graphic. • • • • 70% of the configured power 80% of the configured power 90% of the configured power 95% of the configured...

Open the catalog to page 2

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4 Pages

  2. TCP2RS+

    4 Pages

  3. LM4I4O-M

    4 Pages

Archived catalogs

  1. Short-Form 2021

    162 Pages

  2. CSB

    2 Pages

  3. RG1M

    2 Pages

  4. RGE

    2 Pages

  5. WGC series

    2 Pages

  6. RGU10

    2 Pages

  7. LVC

    1 Pages

  8. TSA

    2 Pages

  9. R-RE-RBE

    2 Pages

  10. CLZ-FP-HD

    5 Pages

  11. CV

    2 Pages

  12. computer MAX

    2 Pages

  13. LR-LRB

    3 Pages

  14. CR Series

    1 Pages

  15. WI

    2 Pages

  16. MCB

    2 Pages

  17. WGBU

    3 Pages

  18. C80

    4 Pages

  19. AR5L

    9 Pages

  20. TSR

    1 Pages

  21. C-convert

    9 Pages

  22. MEG

    2 Pages

  23. SYNCHROMAX

    3 Pages

  24. UC Series

    3 Pages

  25. SMC-STC

    3 Pages

  26. FMZ-FTZ

    3 Pages

  27. WMC-WTC

    5 Pages

  28. EC-V

    5 Pages

  29. EC-A

    5 Pages

  30. RAPTION 150

    2 Pages

  31. URBAN

    2 Pages

  32. CVM-A Series

    7 Pages

  33. BM-V

    3 Pages

  34. PGR Series

    2 Pages

  35. LM4I/4O-M

    2 Pages

  36. RGU-10B

    2 Pages

  37. CEM-C20

    2 Pages

  38. CEM-C10

    2 Pages

  39. OPTIM-HYB

    2 Pages

  40. RVE2-P

    2 Pages

  41. cSMARTIII

    2 Pages

  42. AR6

    2 Pages

  43. CVM-C5

    2 Pages

  44. FRE

    2 Pages

  45. MT-FDE

    2 Pages

  46. RECmaxMP

    2 Pages

  47. RECmaxLPD

    2 Pages

  48. CBS4

    2 Pages

  49. RGU2

    2 Pages

  50. CIRWATT-B100

    2 Pages

  51. FEMC-FETC

    3 Pages

  52. HC

    2 Pages

  53. BC-V

    3 Pages

  54. BC-A

    3 Pages

  55. TL-5

    1 Pages

  56. CIRWATT-B505

    2 Pages

  57. Type B

    8 Pages

  58. MS

    1 Pages

  59. FLEX-R

    1 Pages

  60. TRMC

    2 Pages

  61. RS2RS

    1 Pages

  62. ReadWatt

    2 Pages

  63. DIR2

    1 Pages