LR-LRB - 1

LR / LRB Reactors Reactors for filtering for power converters (network side) Description The motor speed regulation equipment, frequency variators, UPS units, etc. generate alterations in the network, which affect other loads in the installation of the operation of the equipment. The LR / LRB reactors connected to the input on the network side of the equipment can attenuate voltage peaks and reduce the harmonic distortion generated by the power electronics. The LR / LRB Reactors for filtering can reduce the current harmonics in any converter from 40... 50 % to values around 20 %. In addition, they reduce the shortcircuit current and increase the safety of the converter's semi-conductors. When installed on the motor side, they can attenuate harmonic frequencies caused during switching operations. }} Low-powered reactors, LR type, are built with plates with low losses and are coiled with copper wire. The connection is achieved with the adequate terminals. }} the case of higher currents, LRB reacIn tors are used, with a magnetic plate nucleus and multiple steel cores, which offer excellent characteristics and a low loss ratio. Copper band coils (or aluminium band, on demand). The connections run through a plate. }} Both LR and LRB type reactors have a vacuum varnish sealing to increase the insulation, providing a greater mechanical resistance and reduce the level of noise. Features Features Voltage drop Uk % (LR 04: 400 V or Lr 02: 230 V) 4 % network at 50 Hz (4.8 % network at 60 Hz) Other values on demand In accordance with the table Other values on demand Nominal current In accordance with the table Other values on demand LR: copper wire LRB: copper band (or aluminium, on demand) Isolation voltage Maximum room temperature Internal isolation Class F (155 ºC) On demand: class H (180 ºC) Maximum overload Permanent Safety Protection thermostat Application The reactors of the LR / LRB series are prepared and can be used on the network and motor sides. They attenuate micro-drops and peaks during the initial connection and switching operations, and they reduce the rate of harmonics from the network curren

Open the catalog to page 1
LR-LRB - 2

Reactors for filtering for power converters (network side) References Type of threephase network at:

Open the catalog to page 2
LR-LRB - 3

Reactors for filtering for power converters (network side) References Type of threephase network at:

Open the catalog to page 3

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4 Pages

  2. TCP2RS+

    4 Pages

  3. LM4I4O-M

    4 Pages

Archived catalogs

  1. Short-Form 2021

    162 Pages

  2. CSB

    2 Pages

  3. RG1M

    2 Pages

  4. RGE

    2 Pages

  5. WGC series

    2 Pages

  6. RGU10

    2 Pages

  7. LVC

    1 Pages

  8. TSA

    2 Pages

  9. R-RE-RBE

    2 Pages

  10. CLZ-FP-HD

    5 Pages

  11. CV

    2 Pages

  12. computer MAX

    2 Pages

  13. CR Series

    1 Pages

  14. WI

    2 Pages

  15. MCB

    2 Pages

  16. WGBU

    3 Pages

  17. C80

    4 Pages

  18. AR5L

    9 Pages

  19. TSR

    1 Pages

  20. C-convert

    9 Pages

  21. MEG

    2 Pages

  22. SYNCHROMAX

    3 Pages

  23. UC Series

    3 Pages

  24. SMC-STC

    3 Pages

  25. FMZ-FTZ

    3 Pages

  26. WMC-WTC

    5 Pages

  27. EC-V

    5 Pages

  28. EC-A

    5 Pages

  29. RAPTION 150

    2 Pages

  30. URBAN

    2 Pages

  31. CVM-A Series

    7 Pages

  32. BM-V

    3 Pages

  33. PGR Series

    2 Pages

  34. LM4I/4O-M

    2 Pages

  35. RGU-10B

    2 Pages

  36. CEM-C20

    2 Pages

  37. CEM-C10

    2 Pages

  38. OPTIM-HYB

    2 Pages

  39. RVE2-P

    2 Pages

  40. cSMARTIII

    2 Pages

  41. AR6

    2 Pages

  42. CVM-C5

    2 Pages

  43. FRE

    2 Pages

  44. MT-FDE

    2 Pages

  45. RECmaxMP

    2 Pages

  46. RECmaxLPD

    2 Pages

  47. CBS4

    2 Pages

  48. RGU2

    2 Pages

  49. CIRWATT-B100

    2 Pages

  50. FEMC-FETC

    3 Pages

  51. HC

    2 Pages

  52. BC-V

    3 Pages

  53. BC-A

    3 Pages

  54. TL-5

    1 Pages

  55. CIRWATT-B505

    2 Pages

  56. Type B

    8 Pages

  57. MS

    1 Pages

  58. FLEX-R

    1 Pages

  59. TRMC

    2 Pages

  60. RS2RS

    1 Pages

  61. ReadWatt

    2 Pages

  62. DIR2

    1 Pages