Electrical energy meters for partial consumption Centralizing unit with 4 inputs Impulse CENTRALIZING UNIT Centralizing unit with 4 optocoupled inputs and 4 relay-type outputs, with RS-485 communications Description 4-input impulse centralising equipment. Inputs are optoisolated to read impulses and it has a 32-bit memory to store the values metered. }} has an RS-485 communications port It that can be used with an RS-232 or Ethernet converter to read and write the unit's records remotely, using the PowerStudio management software. The RS-485 bus can be used to connect up to 32 units that use this type of communications }} unit's outputs can be programmed to The generate impulses or for remote control actions with the PowerStudio software Features Power supply circuit Digital inputs 4 optoinsulated inputs (voltage-free) Maximum activation current Nominal voltage Electrical endurance Nominal current With resistive load With inductive load (ac) With inductive load (dc) Ambient conditions }} Reading any Impulse-emitting device (up to 4 units). These parameters are useful to generate receipts or define a price/unit cost }} Alarm central: the unit's outputs can act on contacts, sound and/or luminous devices to carry out a protection or warning operation with an internal relay. Humidity (non-condensing) Operating temperature Build features Type of box Degree of protection Fitted unit (frontal) Non-fitted unit (sides and rear cover) Safety Category III - 300 V ac / 520 V ac EN 61010 Double-insulated electric shock protection, Class IIInsulation voltage between the box enclosure and any terminal: 2500 V, 50 Hz, 1 minInsulation between the group of inputs / outputs and the power supply input: 1 GΩ Insulation between the group of inputs and the box enclosure: 1 GΩ Standards IEC 60664, VDE 0110, UL 94, EN61010-1, EN55011, EN61000-4-13, EN61000-4-11, EN61000-6-4, EN61000-4-2, EN61000-6-2, EN61000-6-
Open the catalog to page 1Electrical energy meters for partial consumption Centralizing unit with 4 inputs Impulse CENTRALIZING UNIT Centralizing unit with 4 optocoupled inputs and 4 relay-type outputs, with RS-485 communications References Optoinsulated inputs Relay outputs Communications with the MODBUS (RTU) protocol
Open the catalog to page 22 Pages
4 Pages
2 Pages
8 Pages
8 Pages
20 Pages
12 Pages
4 Pages
4 Pages
8 Pages
16 Pages
12 Pages
34 Pages
32 Pages
64 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
4 Pages
8 Pages
3 Pages
2 Pages
2 Pages
1 Page
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
7 Pages
2 Pages
2 Pages
5 Pages
5 Pages
5 Pages
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
9 Pages
1 Page
9 Pages
4 Pages
3 Pages
2 Pages
1 Page
3 Pages
2 Pages
2 Pages
5 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
40 Pages
2 Pages
2 Pages
162 Pages