Self-reclosing overload and earth leakage protection P2-46 ^

 Open the catalog to page 2

Self-reclosing overload and earth leakage protection Earth leakage protection and self-reclosing RCCB with Self-reclosing system Self-reclosing earth leakage relay Description . Features REC2 is a 2 or 4-pole earth leakage switch associated to a compact motor and control set that enables the automatic and safe re-closure of the installation, provided that the leakage is not permanent. The earth leakage switch is reclosed auto-matically, in accordance with the work mode selected (switch on the front): O Time sequence mode: after a switch trip, REC2 will make 6 reclosing attempts, with a...

 Open the catalog to page 3

Self-reclosing overload and earth leakage protection Earth leakage protection and self-reclosing Self-reclosing earth leakage switch REC2 REC2 - 2 poles ig earth leakage device (g) <g> 1 N H (|) §) Referencesiii^^ Class Poles /n (A) Sensitivity Type Code A 2 40 30 mA REC2-2P-40-30 P26411 A 2 40 300 mA REC2-2P-40-300 P26321 A 2 63 30 mA REC2-2P-63-30 P26414 A 2 63 300 mA REC2-2P-63-300 P26324 A 4 40 30 mA REC2-4P-40-30 P26412 A 4 40 300 mA REC2-4P-40-300 P26322 A 4 63 30 mA REC2-4P-63-30 P26415 A 4 63 300 mA REC2-4P-63-300 P26325 iConnections^ P2-48

 Open the catalog to page 4

Self-reclosing overload and earth leakage protection Earth leakage protection and self-reclosing Earth leakage relay + contactor WRU RA Earth leakage relay with built-in transformer L Description O Self-reclosing electronic earth leakage protection relay with built-in transformer, a diameter of 0 25 or 0 35 mm (depending on the type), with earth leakage trigger O It is connected to a contactor or similar element as a circuit breaker O Type A relay, with high-frequency current filtering and high immunity. Monitoring in true root mean square (TRMS) O Adjustable sensitivity and trigger timer....

 Open the catalog to page 5

Self-reclosing overload and earth leakage protection Earth leakage protection and self-reclosing Earth leakage relay + contactor WRURA Earth leakage relay with built-in transformer WRU-35 RA -105 75 70 o o O O 0 0 o o o o o o O O 0 0 o o 0 35 Useful diameter 0 (mm) < Delay (s) (*) Number of reclosures Time between reclosures (s) Control of the circuit breaker Remote signaling (outputs) Type Code 25 0,03 ... 3 0,02 ... 1 6 8,16, 30,59,115,224 Switched relay mV ac proportional to the leakage current WRU-25 RA P24211 35 0,03 ... 3 0,02 ... 1 6 8,16, 30,59,115,224 Switched relay mV ac...

 Open the catalog to page 6

Self-reclosing overload and earth leakage protection Differential protection and reclosing Differential relay with integrated toroidal transformer + contacte WRU-10 RAL Differential relay with built-in transfo and display (type A) iDescription O Electronic differential protection relay with automatic reclosing with built-in 28 mm transformer, constituting one unit. O Superimmunized Type A , with high-frequency current filter and high insulation. Measurement in true root mean square (TRMS) value O Display with leds and back-lit display: - Differential protection/reclosing settings...

 Open the catalog to page 7

Self-reclosing overload and earth leakage protection Differential protection and reclosing ^Dimensions Differential relay with integrated toroidal transformer + contactor P2-52

 Open the catalog to page 8

Self- Earth leakage protection and self-reclosing Earth protection relay + contacter * externat transformer RGU-10 RAL Earth protection Relay WG Sries ^ss^aari Description Features Fledronic earth leakage [xotecbon relay. usod to conrwd the extomal toroidal trans-formers of ihe WG / WGS / WGC Senos O Sefcredosmg wrth a prograrnmaWe earth kcakagctnp o Supenmmunizod type A Ngsy, wilh hqh frequency current filtering and high immuiity Monitcnng in true RMS Iho backfcght cteptey sfwrs Ihe fotowng iikxmatav * Adjuslment values * Inslantaneous leakage mirent o 1t has hro ind驩pendant outputs > Tnp...

 Open the catalog to page 9

iinlhinllllhWnTyttrfrttlnn Earlh leakage protection and self-reclosing Eanh protection relay + contacter * oxtemal transformer Dimensions RGU-10 RAL Earlh protection Relay WG Sries 52,5 67,9-43.5闗H 0 c o o Ci 0 COOOQQOOB jii!? ■ Rfrences R»cio驮inQ lment Communications KW OeUy (4 Code Contacta - 0.03 . 30 0.02 . 10 RGLM0 RAL P24622 Cont驫tfor 0.03 . 30 0.02 . 10 RGU-10 C RAU PMW Connections L1 UUM CONTACTOR LOAD (^CIRCUTOR

 Open the catalog to page 10

1011 Earlh leakage protection and self-reclosing Ejrth Ik绻gc stJtfon * conTJCtor * cxtcmji transformer CBS-4 RA / RAL Earlh leakage relay station WG / WGC Sries e e © © © Description Fetures Unit equrvalent to 4 earth leakage protec- Protection Earth Laakag* tion reiays 4 independent programm颢t*) re- Ctass A superimmunized iays avaitable 0 4 nputs to connect the exlemal toioKjal transformer» of Ihe WG / WGSf WGC o Setfrodosing wrth programmabto earth fAeasurement True root mean square (TRMS) SenSJtrvrty Delay 003A 30 A Programmable 0 20 ms 10s Inverse curve nstantancous or seicrtw toakage...

 Open the catalog to page 11

Self-reclosing overload and earth leakage protection Earth leakage protection and self-reclosing ^Dimensions^^^^^^ Earth leakage station + contactor + external transformer RA / RAL Earth leakage relay ui Size Communications No. of Relays No. of reclosures Type Code 3 modules - 4 / NO Programmable CBS-4 RA P24911 3 modules RS-485 4 / NO Programmable CBS-4 C RA P24912 3 modules - 4 / NC Programmable CBS-4 RAL P24A11 3 modules RS-485 4 / NC Programmable CBS-4 C RAL P24A12 P2-56 fj^URCUTOR

 Open the catalog to page 12

Self-reclosing overload and earth leakage protection Earth leakage protection and self-reclosing Earth leakage station + contactor + external transfom CBS-8 Earth leakage monitoring and signaling unit of the external transformer of the WG / WGP / WGC Series O Unit equivalent to 8 earth leakage protection networks. 8 independent programmable relays available O 8 inputs to connect the external toroidal transformers of the WG / WGP / WGC O Superimmunized Type A relay with high frequency current filtering and high immunity. Monitoring in true root mean square (TRMS) O Reduced size, with 8...

 Open the catalog to page 13

Self-reclosing overload and earth leakage protection Earth leakage protection and self-reclosing ^Dimensions^^^^^^ Earth leakage station + contactor + external transformer CBS-8 Earth leakage m nomtonng ana signaiing unit of the external transformer of the WG / WGP / WGC Series Size Communications No. of Relays 'n (A) Type Code 8 modules RS-485 8 0,03 ... 63 CBS-8 " P12811 (*) In the case of the 0.3 ... 63 A scale, use earth leakage transformers of the WGP / WGSP (*) In the case of the 0.03 ... 6.3 A scale, use earth leakage transformers of the WG / WGS P2-58

 Open the catalog to page 14

All CIRCUTOR catalogs and technical brochures

  1. LM4I4O-M

    4 Pages

  2. CIRWATT-B505

    2 Pages

  3. WGC series

    2 Pages

  4. RGU-10/CBS-4

    8 Pages

  5. RG1M

    2 Pages

  6. Type B

    8 Pages

  7. MS

    1 Pages

  8. FLEX-R

    1 Pages

  9. TRMC

    2 Pages

  10. RS2RS

    1 Pages

  11. ReadWatt

    2 Pages

  12. DIR2

    1 Pages