Catalog excerpts
Power analyzers Technology for energy efficiency
Open the catalog to page 1More than simply measuring... Record the real cost of your manufacturing processes and the kgCO2 emissions of your installation during different time bands. Record the total cost of electrical energy consumed by your installation, including the operating time of each line, process or activity. Obtain information about a large number of electrical variables in real time to achieve the maximum energy efficiency of your installations. Use your inputs and outputs to manage loads and processes, and to combine different communication modes used in your installation to gather data. A vast range of...
Open the catalog to page 2Much more than a power analyzer The most complete range Always with our customers in mind CIRCUTOR's power analyzers are much Our products are suited to any type of insta- CIRCUTOR has a vast network of professio- more than a simple power analyzer. These llation and space; they can be mounted on a nals that are always ready to help you choose units feature many different communication panel or DIN rail in both High and Low Voltage the best product, adapted to your needs and options, inputs and outputs used to control installations. Our offer ranges from the most those of your customers. In...
Open the catalog to page 3Why should you install a power analyzer? Gathering information is vital to know, understand and perform actions that reduce the cost of energy. / Learn more about where and when you are consuming / Control and reduce unnecessary and inefficient consumption / Anticipate possible penalties due to excess power or the consumption of reactive energy and remove them from your electricity bill / The software can perform a continuous and simple energy and electric audit Connect to http://powerstudio.circutor.com Power, .circutor.com studio Permanently communicated You can get the most out of the...
Open the catalog to page 4Where are analyzers installed? Main Distribution Switchboards Secondary Switchboards Devices with high performance and Devices dedicated to register Devices dedicated to read loads accuracy for monitoring, registering electrical parameters and energy and controlling energy and electrical consumption in distribution switch- the lines or secondary Low Volta- variables of any installation. Specia- boards. Provide relevant information ge switchboards. Those gives fully related the status of each electrical information related the status and dium Voltage applications or in the line as well as...
Open the catalog to page 5Panel mounted Power Analyzers The CVM series of panel mounted analyzers ding information associated with Electrical (96x96 or 144x144) features very accurate Energy Efficiency management parameters, units, which have been designed to control showing different variables, such as: kgCO2 and supervise the main electrical parameters Emissions, Cost of energy and Operating of different network topologies: Single-phase, time. The different combinations of inputs and Two-phase with or without neutral and Three- outputs can check your installation to prevent phase with or without neutral. The unit...
Open the catalog to page 6Power Analyzers for assembly on DIN Rail The CVM series of DIN rail analyzers features secondary (depending on the model) or with units that have been especially designed for installation on switchboards or industrial mA). The units feature ITF technology: galva- machinery. Their main purpose is to control nic insulation protection Therefore, CIRCU- and supervise the main electrical parameters TOR offers a wide range of power analyzers of different network topologies: Single-phase, for assembly on DIN rails to the market, which Two-phase with or without neutral and Three- take up less space...
Open the catalog to page 7CVM - Power Analyzers @ 2017 CIRCUTOR, SA — circutor
Open the catalog to page 8CVM - Power Analyzers @ 2017 CIRCUTOR, SA — circutor.com — cen
Open the catalog to page 9Multifunctional multimeter for panel Description The CVM-C5 is a panel mounted (96 x 96 mm) multimeter that records energy values. Compact and intuitive, with 4-quadrant measurement (Consumption and Generation). The CVM-C5 is suitable for Low Voltage installations, in both 3 and 4-wire three-phase circuits, two-phase circuits with or without neutral, single-phase circuits or ARON connections. Display features and interface: — Quick display of parameters with a single button — Clearly displays the electric parameters of the installation — Displays the electricity consumption value according...
Open the catalog to page 10Fixed power analyzers Multifunctional multimeter for panel References Current input Connections Three-phase + neutral connection with or without voltage transformers Single-phase connection with or without voltage transformers Alimentación Auxiliar Alimentación Auxiliar Power Supply Power Supply POWER SUPPLY POWER SUPPLY CVM – Power Analyzers @ 2017 CIRCUTOR, SA — circutor.com — central@circutor.com
Open the catalog to page 11Power analyzer for panel Description The CVM-C10 is a panel mounted (96 x 96 mm) power analyzer that records energy values. Compact and versatile, with 4-quadrant measurement (consumption and generation). Suitable for Medium or Low voltage installations, in both 3 or 4-wire three-phase circuits, two-phase circuits with or without neutral, single-phase circuits or ARON connections. Display features and interface: — Backlit touch-screen (capacitive) — Analogue display of instantaneous parameters (power, maximum power reached and cos 9 or PF) — Backlit display — Alarm LED indicator. — Tariff...
Open the catalog to page 12Power analyzers Power analyzer for panel Other features: — Modbus RS-485 serial communications — 2 transistor outputs, configurable for impulses or alarms — 2 relay outputs, configurable for alarms — 2 digital inputs for selecting three tariffs or detecting logical states — Allows for tariff selection through communications — Precision class 0.5% in voltage, current and power. — Class 1 in active energy and Class 2 in reactive energy. References Transistor output Current measurement channels Current input Connections Three-phase + neutral connection with or without voltage transformers...
Open the catalog to page 13All CIRCUTOR catalogs and technical brochures
-
Filtering solutions
16 Pages
-
BC48 15V
4 Pages
-
DCB, Digital instruments
2 Pages
-
WRU-10, Smart protection
2 Pages
-
REC4, Self-reclosing RCCB
8 Pages
-
Electric Vehicle Charging
8 Pages
-
Solutions for AMI systems
20 Pages
-
Solutions for ISO 50001
12 Pages
-
TCP2RS+
4 Pages
-
LM4I4O-M
4 Pages
-
Solar photovoltaic canopies
8 Pages
-
Solutions for Self-consumption
16 Pages
-
MYeBOX Connected to efficiency
12 Pages
Archived catalogs
-
Short-Form 2021
162 Pages
-
CSB
2 Pages
-
RG1M
2 Pages
-
RGE
2 Pages
-
WGC series
2 Pages
-
RGU10
2 Pages
-
LVC
1 Pages
-
TSA
2 Pages
-
R-RE-RBE
2 Pages
-
CLZ-FP-HD
5 Pages
-
CV
2 Pages
-
computer MAX
2 Pages
-
LR-LRB
3 Pages
-
CR Series
1 Pages
-
WI
2 Pages
-
MCB
2 Pages
-
WGBU
3 Pages
-
C80
4 Pages
-
AR5L
9 Pages
-
TSR
1 Pages
-
C-convert
9 Pages
-
MEG
2 Pages
-
SYNCHROMAX
3 Pages
-
UC Series
3 Pages
-
SMC-STC
3 Pages
-
FMZ-FTZ
3 Pages
-
WMC-WTC
5 Pages
-
EC-V
5 Pages
-
EC-A
5 Pages
-
RAPTION 150
2 Pages
-
URBAN
2 Pages
-
CVM-A Series
7 Pages
-
BM-V
3 Pages
-
PGR Series
2 Pages
-
SGE-PLC Series
2 Pages
-
LM4I/4O-M
2 Pages
-
RGU-10B
2 Pages
-
CEM-C20
2 Pages
-
CEM-C10
2 Pages
-
OPTIM-HYB
2 Pages
-
RVE2-P
2 Pages
-
cSMARTIII
2 Pages
-
AR6
2 Pages
-
CVM-C5
2 Pages
-
FRE
2 Pages
-
MT-FDE
2 Pages
-
RECmaxMP
2 Pages
-
RECmaxLPD
2 Pages
-
CBS4
2 Pages
-
RGU2
2 Pages
-
CIRWATT-B100
2 Pages
-
FEMC-FETC
3 Pages
-
HC
2 Pages
-
BC-V
3 Pages
-
BC-A
3 Pages
-
TL-5
1 Pages
-
CIRWATT-B505
2 Pages
-
CIRWATT B 502
2 Pages
-
Type B
8 Pages
-
C-FLEX Series
4 Pages
-
MS
1 Pages
-
FLEX-R
1 Pages
-
CIRWATT B 410T
3 Pages
-
TRMC
2 Pages
-
RS2RS
1 Pages
-
ReadWatt
2 Pages
-
Módem Router 3G
2 Pages
-
DIR2
1 Pages
-
computer Smart
2 Pages
-
Smart earth leakage protection
32 Pages
-
ANALOGUE INSTRUMENTS
64 Pages
-
DIGITAL INSTRUMENTS
34 Pages