CVM-E3-MINI-WiEth Power analyzer with Wi-Fi and Ethernet communications
Open the catalog to page 1CVM-E3-MINI-WiEth Easier than ever The CVM-E3-MINI-WiEth power analyzer lets you gather information on the energy consumption and electrical parameters of your installation quickly and easily. It has Ethernet and Wi-Fi communications that provide real-time information to the Energy Management System (EMS), without having to install wiring for communications. Its Bluetooth connectivity can be used to set up communications parameters (Ethernet or Wi-Fi) through the free MyConfig app on your mobile or tablet, without having to physically access the device.
Open the catalog to page 2CVM-E3-MINI-ITF-WiEth Via transformers .../5A or .../1A CVM-E3-MINI-MC-WiEth Via efficient transformers .../250mA CVM-E3-MINI-FLEX-WiEth Via flexible sensors (Rogowski)
Open the catalog to page 3You don't need anything else Bluetooth connection Use Bluetooth connectivity to program Ethernet or Wi-Fi communications without the need for a computer. With the free MyConfig app, you can set up the communications on your power analyzer quickly and easily. MyCONFIG The free app for setting up CIRCUTOR devices via Bluetooth. — Easily set up its communications through bluetooth.
Open the catalog to page 4Wi-Fi connection Ethernet connection Connect the analyzer to your Wi-Fi network and start registering all your consumptions and electrical parameters from your installation. Check the Wi-Fi coverage and assigned IP address directly from its display. Connect the analyzer to your Wi-Fi network and start registering all your consumptions and electrical parameters from your installation. Quickly check the device IP and MAC address by its display any time. Compatible with PowerStudio — Manage your installation wirelessly. Compatible with PowerStudio — Connect the analyzer to the local network...
Open the catalog to page 5Monitor any parameter in your installation Measure over 250 electrical parameters in real time (RMS, maximum and minimum values) and record active, reactive inductive or capacitive and apparent energy for consumption or generation facilities (4 quadrants). Record parameters such as THD% and individual harmonics (voltage and current) up to 31o to check the quality of your consumption. New system with Plug&On sealable terminals Protects any user against direct contact with live components, ensures the accuracy of the measurements by sealing the terminals and detect potential tampering....
Open the catalog to page 6Technical specifications Power supply circuit Nominal voltage Frequency Voltage measurement circuit Current measurement circuit Voltage measuring range Frequency measuring range Current measurement margin Accuracy of the measurements Nominal current (In) Minimum measurement current (I tart) s Voltage measurement Current measurement Active energy measurement Reactive energy measurement IEEE 802.11b/g, IEEE 802.11n (up to 150 Mbps) Bluetooth v4.2 BR/EDR and Bluetooth LE specification NZIF receiver with 97 dBm sensitivity Class-1, class-2 and class-3 transmitter Adaptive Frequency Hopping...
Open the catalog to page 7Vial Sant Jordi, s/n 08232 Viladecavalls Barcelona (Spain) t. +34. 93 745 29 00 info@circutor.com CIRCUTOR, SA reserves the right to modify any information contained in this catalogue.
Open the catalog to page 8All CIRCUTOR catalogs and technical brochures
-
Filtering solutions
16 Pages
-
BC48 15V
4 Pages
-
DCB, Digital instruments
2 Pages
-
WRU-10, Smart protection
2 Pages
-
REC4, Self-reclosing RCCB
8 Pages
-
Electric Vehicle Charging
8 Pages
-
Solutions for AMI systems
20 Pages
-
Solutions for ISO 50001
12 Pages
-
TCP2RS+
4 Pages
-
LM4I4O-M
4 Pages
-
Solar photovoltaic canopies
8 Pages
-
Solutions for Self-consumption
16 Pages
-
MYeBOX Connected to efficiency
12 Pages
Archived catalogs
-
Short-Form 2021
162 Pages
-
CSB
2 Pages
-
RG1M
2 Pages
-
RGE
2 Pages
-
WGC series
2 Pages
-
RGU10
2 Pages
-
LVC
1 Pages
-
TSA
2 Pages
-
R-RE-RBE
2 Pages
-
CLZ-FP-HD
5 Pages
-
CV
2 Pages
-
computer MAX
2 Pages
-
LR-LRB
3 Pages
-
CR Series
1 Pages
-
WI
2 Pages
-
MCB
2 Pages
-
WGBU
3 Pages
-
C80
4 Pages
-
AR5L
9 Pages
-
TSR
1 Pages
-
C-convert
9 Pages
-
MEG
2 Pages
-
SYNCHROMAX
3 Pages
-
UC Series
3 Pages
-
SMC-STC
3 Pages
-
FMZ-FTZ
3 Pages
-
WMC-WTC
5 Pages
-
EC-V
5 Pages
-
EC-A
5 Pages
-
RAPTION 150
2 Pages
-
URBAN
2 Pages
-
CVM-A Series
7 Pages
-
BM-V
3 Pages
-
PGR Series
2 Pages
-
SGE-PLC Series
2 Pages
-
LM4I/4O-M
2 Pages
-
RGU-10B
2 Pages
-
CEM-C20
2 Pages
-
CEM-C10
2 Pages
-
OPTIM-HYB
2 Pages
-
RVE2-P
2 Pages
-
cSMARTIII
2 Pages
-
AR6
2 Pages
-
CVM-C5
2 Pages
-
FRE
2 Pages
-
MT-FDE
2 Pages
-
RECmaxMP
2 Pages
-
RECmaxLPD
2 Pages
-
CBS4
2 Pages
-
RGU2
2 Pages
-
CIRWATT-B100
2 Pages
-
FEMC-FETC
3 Pages
-
HC
2 Pages
-
BC-V
3 Pages
-
BC-A
3 Pages
-
TL-5
1 Pages
-
CIRWATT-B505
2 Pages
-
CIRWATT B 502
2 Pages
-
CVM Power analyzers
40 Pages
-
Type B
8 Pages
-
C-FLEX Series
4 Pages
-
MS
1 Pages
-
FLEX-R
1 Pages
-
CIRWATT B 410T
3 Pages
-
TRMC
2 Pages
-
RS2RS
1 Pages
-
ReadWatt
2 Pages
-
Módem Router 3G
2 Pages
-
DIR2
1 Pages
-
computer Smart
2 Pages
-
Smart earth leakage protection
32 Pages
-
ANALOGUE INSTRUMENTS
64 Pages
-
DIGITAL INSTRUMENTS
34 Pages