Catalog excerpts
CVM-A1500 Power analyzer with power quality
Open the catalog to page 1Quality in every sense of the word Class A Poor voltage quality supplied by the electric company affects the proper operation of your installation, which has a direct effect on equipment, production systems or the level of service of your business. When the voltage in your installation is too high or too low for the loads connected, whether temporarily or all the time, it can cause service outages or interruptions that can cost you money. The CVM-A1500 power quality analyzer is specially designed to record the signal quality of your installation and detect anomalous events such as...
Open the catalog to page 2CVM-A1500 Power analyzer with power quality The quality of your installation under supervision CVM-A1500 is designed to monitor, supervise electrical parameters and detect Power quality events. It is an ideal device to be installed at the most relevant measuring points, such as mains or any problematic line or machine. CVM-A1500 shows a wide range of electrical parameters, including: Current and power demands, phase-phase and per phase Power quality variables: Unbalance, Asymmetry, Flicker, etc. Phasor Diagram Recording of power quality events every ½ cycle with: date, time, duration and...
Open the catalog to page 3The quality of your installation under supervision Easy, simple and accessible The unit has a very user-friendly interface. You can access your data instantaneously using any browser, displaying instantaneous values, charts and tables, and also export data quickly and easily. Waveform capture Oscilloscope in real time The analyzer captures the voltage and current wave shape when it detects quality events or deformation of the voltage wave, storing them internally to be analyzed online or downloading the data to PowerStudio. It shows voltage and current wave shapes in real time and has...
Open the catalog to page 4RS-485 ethernet EMS integrated The unit includes the datalogger module with embedded PowerStudio: the analysis tool that gives you access to all the information recorded by the analyzer and provides it with Ethernet. It shows averages with different configurations, including maximums, minimums, energy increments, quality events with their associated wave shape, alarms logged and additional calculations programmed by the user. Expandable in many ways Modular and expandable thanks to its expansion modules; this makes it more versatile as you can add different types of communication and...
Open the catalog to page 5Installation without interruption The most flexible version Install the FLEX version in all those installations where interrupting the power is not an option. The CVM-A1500-FLEX power analyzer allows connecting flexible current clamps (FLEX-MAG) to read the current and any associated electrical parameters, such as energy and power. The flexible clamps are designed for installations of up to 10000 A with diameters of 70 or 120 mm, spanning distances up to 5 meters from the measuring point to the analyzer. Applications Industry Production processes Tertiary sector
Open the catalog to page 6Technical features Power supply circuit DC consumption Voltage measurement circuit Power supply voltage Voltage range Current measurement circuit Current measurement Input current Maximum transformation ratios Primary V: 500,000 (500 kV) Primary A: 999.9 to 1.0 (10 kA) in .../5 A and .../1 A, 63...2000 A in MC Prim V x Prim A < 60 MW Maximum energy meter value (total) Accuracy class (.../5 A) (Consult other accuracies) Neutral voltage Neutral current Active Power Reactive Power Active energy Reactive energy Voltage / Current Digital inputs 2, Optoisolated potential-free contact Digital...
Open the catalog to page 7Vial Sant Jordi, s/n 08232 Viladecavalls Barcelona (Spain) t. +34. 93 745 29 00 info@circutor.com CIRCUTOR, SAU reserves the right to change any information contained in this catalogue.
Open the catalog to page 8All CIRCUTOR catalogs and technical brochures
-
Filtering solutions
16 Pages
-
BC48 15V
4 Pages
-
DCB, Digital instruments
2 Pages
-
WRU-10, Smart protection
2 Pages
-
REC4, Self-reclosing RCCB
8 Pages
-
Electric Vehicle Charging
8 Pages
-
Solutions for AMI systems
20 Pages
-
Solutions for ISO 50001
12 Pages
-
TCP2RS+
4 Pages
-
LM4I4O-M
4 Pages
-
Solar photovoltaic canopies
8 Pages
-
Solutions for Self-consumption
16 Pages
-
MYeBOX Connected to efficiency
12 Pages
Archived catalogs
-
Short-Form 2021
162 Pages
-
CSB
2 Pages
-
RG1M
2 Pages
-
RGE
2 Pages
-
WGC series
2 Pages
-
RGU10
2 Pages
-
LVC
1 Pages
-
TSA
2 Pages
-
R-RE-RBE
2 Pages
-
CLZ-FP-HD
5 Pages
-
CV
2 Pages
-
computer MAX
2 Pages
-
LR-LRB
3 Pages
-
CR Series
1 Pages
-
WI
2 Pages
-
MCB
2 Pages
-
WGBU
3 Pages
-
C80
4 Pages
-
AR5L
9 Pages
-
TSR
1 Pages
-
C-convert
9 Pages
-
MEG
2 Pages
-
SYNCHROMAX
3 Pages
-
UC Series
3 Pages
-
SMC-STC
3 Pages
-
FMZ-FTZ
3 Pages
-
WMC-WTC
5 Pages
-
EC-V
5 Pages
-
EC-A
5 Pages
-
RAPTION 150
2 Pages
-
URBAN
2 Pages
-
CVM-A Series
7 Pages
-
BM-V
3 Pages
-
PGR Series
2 Pages
-
SGE-PLC Series
2 Pages
-
LM4I/4O-M
2 Pages
-
RGU-10B
2 Pages
-
CEM-C20
2 Pages
-
CEM-C10
2 Pages
-
OPTIM-HYB
2 Pages
-
RVE2-P
2 Pages
-
cSMARTIII
2 Pages
-
AR6
2 Pages
-
CVM-C5
2 Pages
-
FRE
2 Pages
-
MT-FDE
2 Pages
-
RECmaxMP
2 Pages
-
RECmaxLPD
2 Pages
-
CBS4
2 Pages
-
RGU2
2 Pages
-
CIRWATT-B100
2 Pages
-
FEMC-FETC
3 Pages
-
HC
2 Pages
-
BC-V
3 Pages
-
BC-A
3 Pages
-
TL-5
1 Pages
-
CIRWATT-B505
2 Pages
-
CIRWATT B 502
2 Pages
-
CVM Power analyzers
40 Pages
-
Type B
8 Pages
-
C-FLEX Series
4 Pages
-
MS
1 Pages
-
FLEX-R
1 Pages
-
CIRWATT B 410T
3 Pages
-
TRMC
2 Pages
-
RS2RS
1 Pages
-
ReadWatt
2 Pages
-
Módem Router 3G
2 Pages
-
DIR2
1 Pages
-
computer Smart
2 Pages
-
Smart earth leakage protection
32 Pages
-
ANALOGUE INSTRUMENTS
64 Pages
-
DIGITAL INSTRUMENTS
34 Pages