Specifications:
The portable power analyzer M8-23 is designed for both single and three-phase systems. It operates with a power supply of 2 x 1.5 V DC (LR6 AA-type batteries) and measures nominal voltages between 50 to 500 Vac with a frequency range of 45 to 65 Hz. The device can handle a voltage overload of 10% (up to 550 V ac) and a current overload of 10%. It offers a class accuracy of 0.5% ± 2 digits for voltage and current, and 1% ± 2 digits for power rating. The analyzer has an operating autonomy of 200 hours and features a 7-segment display with 3 lines x 4 digits.
Build Features:
The device includes 1 on/off button and 7 function keys. It supports voltage terminals L1, L2, L3 / N and a current clamp connector with 4 wires for automatic detection. The dimensions are 172 x 100 x 50 mm, and it weighs 300 g. Accepted clamps include CP 2000/200, CP 1000, CP 500, CP 100, CP 5, CF-5, and C-FLEX 200 / 2000 / 20000.
Safety and Standards:
The analyzer complies with IEC 61010-6-1 for electrical safety and various IEC standards for emissions and immunity in different environments, including IEC 61000-6-3, IEC 61000-6-4, IEC 61000-6-2, and others.
Features and Applications:
The analyzer measures main electrical parameters for single-phase, balanced, and unbalanced three-phase networks. It can measure energy, THD in A and V, detect leakage currents, and determine phase rotation. It has an internal memory for automatic parameter recording and displays maximum and minimum values. The device is compact, robust, and easy to use, with auto-detection of clamps. It can calculate the capacity in kvar for installation compensation and display energies compensated with a capacitor bank. It also creates harmonic distortion alarms to detect resonances.
Clamps and Accessories:
Various clamps are available, including CP-100, CPR-1000, CP-2000/200, CPR-500, CP-5, and C-FLEX clamps with different measurement ranges and specifications. Each clamp type has specific codes for identification and compatibility with the analyzer.
See more

Catalog excerpts

C80-1

Portable power analyzer Portable single and three-phase power analyzer Description }} Measurement of the main electrical parameters of a single-phase network, balanced three-phase network and unbalanced three-phase network with neutral }} Measurement of energy }} Measurement of the THD in A and V }} Detects leakage currents and the turning direction of phases }} Internal memory to record parameters automatically }} Display of the maximum and minimum values of electrical parameters }} Reduced size and weight (300g) very robust and easy to use }} Auto-detection of clamp Features Power supply circuit Voltage Measurement circuit Nominal voltage Nominal current 2 V (automatic, depending on the clamp) Voltage overload Current overload Class/Accuracy Voltage Power rating Build features }} Calculation of the capacity in kvar to compensate the installation }} Display of energies compensated with a determined capacitor bank }} Creation of harmonic distortion alarms to detect resonances Operating autonomy 1 on/off + 7 function keys 7 segments, 3 lines x 4 digits, indication icons Voltage terminals Current clamp connector 4 wires (ID signal -> automatic detection) Circular file (between 1 and 90 min) Accepted clamps Safety IEC 61010-6-1 Standards IEC 61000-6-3: 1996, Emissions in residential and commercial environments and light industry CISPR 11:1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-4: 1997, Emissions in industrial environments. CISPR 11: 1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-2:1999, Immunity in industrial environments IEC 61000-4-2:1995, Electrostatic discharge IEC 61000-4-3:2002, Radiated electromagnetic field IEC 61000-4-4:1995, Rapid transient bursts IEC 61000-4-5:1995, Shockwaves IEC 61000-4-6:1996, RF in common mode IEC 61000-4-8:1993, Magnetic field at 50 Hz IEC 61000-6-1:1997, Immunity in residential and commercial environments and light industry IEC 61000-4-5:1995, Shockwaves IEC 61010-6-1:2001, Electrical security

 Open the catalog to page 1
C80-2

Portable power analyzer Parameters measured Balanced Three-phase / Single-phase system Portable single and three-phase power analyzer Symbol (unit) Reactive power (L and C) Type Active power Apparent power Power factor Active energy All kits include 3 voltage cables + case Connections Balanced Three-phase System Balanced single-phase system

 Open the catalog to page 2
C80-3

Portable power analyzer Portable single and three-phase power analyzer Measurement range Nominal frequency Output voltage Dielectric rigidity Scale base error Maximum conductor diameter Maximum busbar Measurement range Measurement range Nominal frequency Nominal frequency Output voltage Output voltage Dielectric rigidity Dielectric rigidity Scale base error Scale base error Maximum conductor diameter Maximum conductor diameter Maximum busbar Maximum busbar Measurement range Measurement range Nominal frequency Output voltage Nominal frequency Dielectric rigidity Output voltage Scale base error...

 Open the catalog to page 3
C80-4

Portable power analyzer Portable single and three-phase power analyzer C-FLEX Clamps 20 000 / 2000 / 200 A-120 Longitude sensor Scale 200 or 100: 10 mV / A Scale 2000 or 1000: 1 mV / AScale 20k or 10k: 0.1 mV / A Measurement amplitude Electrical safety Double insulation IEC 1010 - 100 V - Cat III Degree of contamination 2 Admissible output overvoltage Ambient conditions Temperature Longitude sensor Longitude sensor Scale 200 or 100: 10 mV / A Scale 2000 or 1000: 1 mV / AScale 20k or 10k: 0.1 mV / A Scale 200 or 100: 10 mV / A Scale 2000 or 1000: 1 mV / AScale 20k or 10k: 0.1 mV / A Measurement...

 Open the catalog to page 4

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4  Pages

  2. TCP2RS+

    4  Pages

  3. LM4I4O-M

    4  Pages

Archived catalogs

  1. DIR2

    1  Page

  2. ReadWatt

    2  Pages

  3. RS2RS

    1  Page

  4. FLEX-R

    1  Page

  5. MS

    1  Page

  6. C-FLEX Series

    4  Pages

  7. Type B

    8  Pages

  8. CIRWATT B 502

    2  Pages

  9. CIRWATT-B505

    2  Pages

  10. TL-5

    1  Page

  11. BC-A

    3  Pages

  12. BC-V

    3  Pages

  13. HC

    2  Pages

  14. FEMC-FETC

    3  Pages

  15. CIRWATT-B100

    2  Pages

  16. RGU2

    2  Pages

  17. CBS4

    2  Pages

  18. RECmaxLPD

    2  Pages

  19. RECmaxMP

    2  Pages

  20. MT-FDE

    2  Pages

  21. FRE

    2  Pages

  22. CVM-C5

    2  Pages

  23. AR6

    2  Pages

  24. cSMARTIII

    2  Pages

  25. RVE2-P

    2  Pages

  26. OPTIM-HYB

    2  Pages

  27. CEM-C10

    2  Pages

  28. CEM-C20

    2  Pages

  29. RGU-10B

    2  Pages

  30. LM4I/4O-M

    2  Pages

  31. TRMC

    2  Pages

  32. PGR Series

    2  Pages

  33. BM-V

    3  Pages

  34. CVM-A Series

    7  Pages

  35. URBAN

    2  Pages

  36. RAPTION 150

    2  Pages

  37. EC-A

    5  Pages

  38. EC-V

    5  Pages

  39. WMC-WTC

    5  Pages

  40. FMZ-FTZ

    3  Pages

  41. SMC-STC

    3  Pages

  42. UC Series

    3  Pages

  43. SYNCHROMAX

    3  Pages

  44. MEG

    2  Pages

  45. C-convert

    9  Pages

  46. TSR

    1  Page

  47. AR5L

    9  Pages

  48. WGBU

    3  Pages

  49. WI

    2  Pages

  50. CR Series

    1  Page

  51. LR-LRB

    3  Pages

  52. computer MAX

    2  Pages

  53. CV

    2  Pages

  54. CLZ-FP-HD

    5  Pages

  55. R-RE-RBE

    2  Pages

  56. LVC

    1  Page

  57. RGU10

    2  Pages

  58. WGC series

    2  Pages

  59. RGE

    2  Pages

  60. RG1M

    2  Pages

  61. CSB

    2  Pages

  62. MCB

    2  Pages

  63. TSA

    2  Pages

  64. Short-Form 2021

    162  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.