Catalog excerpts

Portable power analyzer Portable single and three-phase power analyzer Description }} Measurement of the main electrical parameters of a single-phase network, balanced three-phase network and unbalanced three-phase network with neutral }} Measurement of energy }} Measurement of the THD in A and V }} Detects leakage currents and the turning direction of phases }} Internal memory to record parameters automatically }} Display of the maximum and minimum values of electrical parameters }} Reduced size and weight (300g) very robust and easy to use }} Auto-detection of clamp Features Power supply circuit Voltage Measurement circuit Nominal voltage Nominal current 2 V (automatic, depending on the clamp) Voltage overload Current overload Class/Accuracy Voltage Power rating Build features }} Calculation of the capacity in kvar to compensate the installation }} Display of energies compensated with a determined capacitor bank }} Creation of harmonic distortion alarms to detect resonances Operating autonomy 1 on/off + 7 function keys 7 segments, 3 lines x 4 digits, indication icons Voltage terminals Current clamp connector 4 wires (ID signal -> automatic detection) Circular file (between 1 and 90 min) Accepted clamps Safety IEC 61010-6-1 Standards IEC 61000-6-3: 1996, Emissions in residential and commercial environments and light industry CISPR 11:1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-4: 1997, Emissions in industrial environments. CISPR 11: 1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-2:1999, Immunity in industrial environments IEC 61000-4-2:1995, Electrostatic discharge IEC 61000-4-3:2002, Radiated electromagnetic field IEC 61000-4-4:1995, Rapid transient bursts IEC 61000-4-5:1995, Shockwaves IEC 61000-4-6:1996, RF in common mode IEC 61000-4-8:1993, Magnetic field at 50 Hz IEC 61000-6-1:1997, Immunity in residential and commercial environments and light industry IEC 61000-4-5:1995, Shockwaves IEC 61010-6-1:2001, Electrical security
Open the catalog to page 1
Portable power analyzer Parameters measured Balanced Three-phase / Single-phase system Portable single and three-phase power analyzer Symbol (unit) Reactive power (L and C) Type Active power Apparent power Power factor Active energy All kits include 3 voltage cables + case Connections Balanced Three-phase System Balanced single-phase system
Open the catalog to page 2
Portable power analyzer Portable single and three-phase power analyzer Measurement range Nominal frequency Output voltage Dielectric rigidity Scale base error Maximum conductor diameter Maximum busbar Measurement range Measurement range Nominal frequency Nominal frequency Output voltage Output voltage Dielectric rigidity Dielectric rigidity Scale base error Scale base error Maximum conductor diameter Maximum conductor diameter Maximum busbar Maximum busbar Measurement range Measurement range Nominal frequency Output voltage Nominal frequency Dielectric rigidity Output voltage Scale base...
Open the catalog to page 3
Portable power analyzer Portable single and three-phase power analyzer C-FLEX Clamps 20 000 / 2000 / 200 A-120 Longitude sensor Scale 200 or 100: 10 mV / A Scale 2000 or 1000: 1 mV / AScale 20k or 10k: 0.1 mV / A Measurement amplitude Electrical safety Double insulation IEC 1010 - 100 V - Cat III Degree of contamination 2 Admissible output overvoltage Ambient conditions Temperature Longitude sensor Longitude sensor Scale 200 or 100: 10 mV / A Scale 2000 or 1000: 1 mV / AScale 20k or 10k: 0.1 mV / A Scale 200 or 100: 10 mV / A Scale 2000 or 1000: 1 mV / AScale 20k or 10k: 0.1 mV / A...
Open the catalog to page 4All CIRCUTOR catalogs and technical brochures
-
BC48 15V
4 Pages
-
DCB, Digital instruments
2 Pages
-
WRU-10, Smart protection
2 Pages
-
REC4, Self-reclosing RCCB
8 Pages
-
Electric Vehicle Charging
8 Pages
-
Solutions for AMI systems
20 Pages
-
Solutions for ISO 50001
12 Pages
-
TCP2RS+
4 Pages
-
LM4I4O-M
4 Pages
-
Solar photovoltaic canopies
8 Pages
-
Solutions for Self-consumption
16 Pages
-
MYeBOX Connected to efficiency
12 Pages
Archived catalogs
-
Short-Form 2021
162 Pages
-
CSB
2 Pages
-
RG1M
2 Pages
-
RGE
2 Pages
-
WGC series
2 Pages
-
RGU10
2 Pages
-
LVC
1 Pages
-
TSA
2 Pages
-
R-RE-RBE
2 Pages
-
CLZ-FP-HD
5 Pages
-
CV
2 Pages
-
computer MAX
2 Pages
-
LR-LRB
3 Pages
-
CR Series
1 Pages
-
WI
2 Pages
-
MCB
2 Pages
-
WGBU
3 Pages
-
AR5L
9 Pages
-
TSR
1 Pages
-
C-convert
9 Pages
-
MEG
2 Pages
-
SYNCHROMAX
3 Pages
-
UC Series
3 Pages
-
SMC-STC
3 Pages
-
FMZ-FTZ
3 Pages
-
WMC-WTC
5 Pages
-
EC-V
5 Pages
-
EC-A
5 Pages
-
RAPTION 150
2 Pages
-
URBAN
2 Pages
-
CVM-A Series
7 Pages
-
BM-V
3 Pages
-
PGR Series
2 Pages
-
SGE-PLC Series
2 Pages
-
LM4I/4O-M
2 Pages
-
RGU-10B
2 Pages
-
CEM-C20
2 Pages
-
CEM-C10
2 Pages
-
OPTIM-HYB
2 Pages
-
RVE2-P
2 Pages
-
cSMARTIII
2 Pages
-
AR6
2 Pages
-
CVM-C5
2 Pages
-
FRE
2 Pages
-
MT-FDE
2 Pages
-
RECmaxMP
2 Pages
-
RECmaxLPD
2 Pages
-
CBS4
2 Pages
-
RGU2
2 Pages
-
CIRWATT-B100
2 Pages
-
FEMC-FETC
3 Pages
-
HC
2 Pages
-
BC-V
3 Pages
-
BC-A
3 Pages
-
TL-5
1 Pages
-
CIRWATT-B505
2 Pages
-
CIRWATT B 502
2 Pages
-
CVM Power analyzers
40 Pages
-
Type B
8 Pages
-
C-FLEX Series
4 Pages
-
MS
1 Pages
-
FLEX-R
1 Pages
-
CIRWATT B 410T
3 Pages
-
TRMC
2 Pages
-
RS2RS
1 Pages
-
ReadWatt
2 Pages
-
Módem Router 3G
2 Pages
-
DIR2
1 Pages
-
computer Smart
2 Pages
-
Smart earth leakage protection
32 Pages
-
ANALOGUE INSTRUMENTS
64 Pages
-
DIGITAL INSTRUMENTS
34 Pages