Catalog excerpts

Portable power analyzer m.B C-80 Portable single and three-phase power analyzer O Measurement of the main electrical parameters of a single-phase network, balanced three-phase network and unbalanced three-phase network with neutral O Measurement of energy O Measurement of the THD in A and V O Detects leakage currents and the turning direction of phases O Internal memory to record parameters automatically O Display of the maximum and minimum values of electrical parameters O Reduced size and weight (300g) very robust and easy to use O Auto-detection of clamp 2 x 1,5 V dc (LR6 AA-type batteries) 50 ... 500 Vac 45 ... 65 Hz 2 V (automatic, depending on the clamp) 10% (550 V ac) 10% 200 hours 1 on/off + 7 function keys 7 segments, 3 lines x 4 digits, indication icons L1, L2, L3 / N 4 wires (ID signal -> automatic detection) Circular file (between 1 and 90 min) 172 x 100 x 50 mm 300 g CP 2000/200, CP 1000, CP 500, CP 100, CP 5, CF-5, C-FLEX 200 / 2000 / 20000 O Calculation of the capacity in kvar to compensate the installation O Display of energies compensated with a determined capacitor bank O Creation of harmonic distortion alarms to detect resonances Operating autonomy Keyboard Display Voltage terminals Current clamp connector Record Dimensions Weight Accepted clamps Safety IEC 61010-6-1 Standards IEC 61000-6-3: 1996, Emissions in residential and commercial environments and light industry CISPR 11:1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-4: 1997, Emissions in industrial environments. CISPR 11: 1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-2:1999, Immunity in industrial environments IEC 61000-4-2:1995, Electrostatic discharge IEC 61000-4-3:2002, Radiated electromagnetic field IEC 61000-4-4:1995, Rapid transient bursts IEC 61000-4-5:1995, Shockwaves IEC 61000-4-6:1996, RF in common mode IEC 61000-4-8:1993, Magnetic field at 50 Hz IEC 61000-6-1:1997, Immunity in residential and commercial environments and light industry IEC 61000-4-5:1995, Shockwaves IEC 61010-6-1:2001, Electrical security
Open the catalog to page 1
Portable power analyzer C-80 Portable single and three-phase power analyzer ^Parameters measured^ Balanced Three-phase / Single-phase system Symbol Parameter (unit) Instantaneous Maximum Minimum Voltage V • • • Current A • • - Frequency Active power Reactive power (L and C) All kits include 3 voltage cables + case Apparent power Power factor Cos <p Active energy Power factor (L) Power factor (C) V A PF cos cp W ■ h var■h L var h C ^°jnection^_ Balanced Three-phase System Balanced single-phase system Umbalanced Three-phase System with neutral
Open the catalog to page 2
Clamps C-80 Portable single and three-phase power analyzer Measurement range Nominal frequency Output voltage Dielectric rigidity Scale base error Maximum conductor diameter Maximum busbar Measurement range Measurement range
Open the catalog to page 3
Portable power analyzer Clamps C-80 Portable single and three-phase power analyzer C-FLEX Clamps 20 000 / 2000 / 200 A-120 Longitude sensor Scales Sensitivity in mV Measurement amplitude Bandwidth Accuracy Electrical safety Admissible output overvoltage Ambient conditions 10...20 kHz 1 % Double insulation IEC 1010 - 100 V - Cat III -Degree of contamination 2 600 V (peak factor 1.5) 10...20 kHz 1 % Double insulation IEC 1010 - 100 V - Cat III -Degree of contamination 2 600 V (peak factor 1.5)
Open the catalog to page 4All CIRCUTOR catalogs and technical brochures
-
BC48 15V
4 Pages
-
DCB, Digital instruments
2 Pages
-
WRU-10, Smart protection
2 Pages
-
REC4, Self-reclosing RCCB
8 Pages
-
Electric Vehicle Charging
8 Pages
-
Solutions for AMI systems
20 Pages
-
Solutions for ISO 50001
12 Pages
-
TCP2RS+
4 Pages
-
LM4I4O-M
4 Pages
-
Solar photovoltaic canopies
8 Pages
-
Solutions for Self-consumption
16 Pages
-
MYeBOX Connected to efficiency
12 Pages
Archived catalogs
-
Short-Form 2021
162 Pages
-
CSB
2 Pages
-
RG1M
2 Pages
-
RGE
2 Pages
-
WGC series
2 Pages
-
RGU10
2 Pages
-
LVC
1 Pages
-
TSA
2 Pages
-
R-RE-RBE
2 Pages
-
CLZ-FP-HD
5 Pages
-
CV
2 Pages
-
computer MAX
2 Pages
-
LR-LRB
3 Pages
-
CR Series
1 Pages
-
WI
2 Pages
-
MCB
2 Pages
-
WGBU
3 Pages
-
C80
4 Pages
-
AR5L
9 Pages
-
TSR
1 Pages
-
C-convert
9 Pages
-
MEG
2 Pages
-
SYNCHROMAX
3 Pages
-
UC Series
3 Pages
-
SMC-STC
3 Pages
-
FMZ-FTZ
3 Pages
-
WMC-WTC
5 Pages
-
EC-V
5 Pages
-
EC-A
5 Pages
-
RAPTION 150
2 Pages
-
URBAN
2 Pages
-
CVM-A Series
7 Pages
-
BM-V
3 Pages
-
PGR Series
2 Pages
-
SGE-PLC Series
2 Pages
-
LM4I/4O-M
2 Pages
-
RGU-10B
2 Pages
-
CEM-C20
2 Pages
-
CEM-C10
2 Pages
-
OPTIM-HYB
2 Pages
-
RVE2-P
2 Pages
-
cSMARTIII
2 Pages
-
AR6
2 Pages
-
CVM-C5
2 Pages
-
FRE
2 Pages
-
MT-FDE
2 Pages
-
RECmaxMP
2 Pages
-
RECmaxLPD
2 Pages
-
CBS4
2 Pages
-
RGU2
2 Pages
-
CIRWATT-B100
2 Pages
-
FEMC-FETC
3 Pages
-
HC
2 Pages
-
BC-V
3 Pages
-
BC-A
3 Pages
-
TL-5
1 Pages
-
CIRWATT-B505
2 Pages
-
CIRWATT B 502
2 Pages
-
CVM Power analyzers
40 Pages
-
Type B
8 Pages
-
MS
1 Pages
-
FLEX-R
1 Pages
-
CIRWATT B 410T
3 Pages
-
TRMC
2 Pages
-
RS2RS
1 Pages
-
ReadWatt
2 Pages
-
Módem Router 3G
2 Pages
-
DIR2
1 Pages
-
computer Smart
2 Pages
-
Smart earth leakage protection
32 Pages
-
ANALOGUE INSTRUMENTS
64 Pages
-
DIGITAL INSTRUMENTS
34 Pages