Catalog excerpts
Portable power analyzer m.B C-80 Portable single and three-phase power analyzer O Measurement of the main electrical parameters of a single-phase network, balanced three-phase network and unbalanced three-phase network with neutral O Measurement of energy O Measurement of the THD in A and V O Detects leakage currents and the turning direction of phases O Internal memory to record parameters automatically O Display of the maximum and minimum values of electrical parameters O Reduced size and weight (300g) very robust and easy to use O Auto-detection of clamp 2 x 1,5 V dc (LR6 AA-type batteries) 50 ... 500 Vac 45 ... 65 Hz 2 V (automatic, depending on the clamp) 10% (550 V ac) 10% 200 hours 1 on/off + 7 function keys 7 segments, 3 lines x 4 digits, indication icons L1, L2, L3 / N 4 wires (ID signal -> automatic detection) Circular file (between 1 and 90 min) 172 x 100 x 50 mm 300 g CP 2000/200, CP 1000, CP 500, CP 100, CP 5, CF-5, C-FLEX 200 / 2000 / 20000 O Calculation of the capacity in kvar to compensate the installation O Display of energies compensated with a determined capacitor bank O Creation of harmonic distortion alarms to detect resonances Operating autonomy Keyboard Display Voltage terminals Current clamp connector Record Dimensions Weight Accepted clamps Safety IEC 61010-6-1 Standards IEC 61000-6-3: 1996, Emissions in residential and commercial environments and light industry CISPR 11:1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-4: 1997, Emissions in industrial environments. CISPR 11: 1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-2:1999, Immunity in industrial environments IEC 61000-4-2:1995, Electrostatic discharge IEC 61000-4-3:2002, Radiated electromagnetic field IEC 61000-4-4:1995, Rapid transient bursts IEC 61000-4-5:1995, Shockwaves IEC 61000-4-6:1996, RF in common mode IEC 61000-4-8:1993, Magnetic field at 50 Hz IEC 61000-6-1:1997, Immunity in residential and commercial environments and light industry IEC 61000-4-5:1995, Shockwaves IEC 61010-6-1:2001, Electrical security
Open the catalog to page 1Portable power analyzer C-80 Portable single and three-phase power analyzer ^Parameters measured^ Balanced Three-phase / Single-phase system Symbol Parameter (unit) Instantaneous Maximum Minimum Voltage V • • • Current A • • - Frequency Active power Reactive power (L and C) All kits include 3 voltage cables + case Apparent power Power factor Cos <p Active energy Power factor (L) Power factor (C) V A PF cos cp W ■ h var■h L var h C ^°jnection^_ Balanced Three-phase System Balanced single-phase system Umbalanced Three-phase System with neutral
Open the catalog to page 2Clamps C-80 Portable single and three-phase power analyzer Measurement range Nominal frequency Output voltage Dielectric rigidity Scale base error Maximum conductor diameter Maximum busbar Measurement range Measurement range
Open the catalog to page 3Portable power analyzer Clamps C-80 Portable single and three-phase power analyzer C-FLEX Clamps 20 000 / 2000 / 200 A-120 Longitude sensor Scales Sensitivity in mV Measurement amplitude Bandwidth Accuracy Electrical safety Admissible output overvoltage Ambient conditions 10...20 kHz 1 % Double insulation IEC 1010 - 100 V - Cat III -Degree of contamination 2 600 V (peak factor 1.5) 10...20 kHz 1 % Double insulation IEC 1010 - 100 V - Cat III -Degree of contamination 2 600 V (peak factor 1.5)
Open the catalog to page 4All CIRCUTOR catalogs and technical brochures
-
BC48 15V
4 Pages
-
DCB, Digital instruments
2 Pages
-
WRU-10, Smart protection
2 Pages
-
REC4, Self-reclosing RCCB
8 Pages
-
Electric Vehicle Charging
8 Pages
-
Solutions for AMI systems
20 Pages
-
Solutions for ISO 50001
12 Pages
-
TCP2RS+
4 Pages
-
LM4I4O-M
4 Pages
-
Solar photovoltaic canopies
8 Pages
-
Solutions for Self-consumption
16 Pages
-
MYeBOX Connected to efficiency
12 Pages
Archived catalogs
-
Short-Form 2021
162 Pages
-
CSB
2 Pages
-
RG1M
2 Pages
-
RGE
2 Pages
-
WGC series
2 Pages
-
RGU10
2 Pages
-
LVC
1 Pages
-
TSA
2 Pages
-
R-RE-RBE
2 Pages
-
CLZ-FP-HD
5 Pages
-
CV
2 Pages
-
computer MAX
2 Pages
-
LR-LRB
3 Pages
-
CR Series
1 Pages
-
WI
2 Pages
-
MCB
2 Pages
-
WGBU
3 Pages
-
C80
4 Pages
-
AR5L
9 Pages
-
TSR
1 Pages
-
C-convert
9 Pages
-
MEG
2 Pages
-
SYNCHROMAX
3 Pages
-
UC Series
3 Pages
-
SMC-STC
3 Pages
-
FMZ-FTZ
3 Pages
-
WMC-WTC
5 Pages
-
EC-V
5 Pages
-
EC-A
5 Pages
-
RAPTION 150
2 Pages
-
URBAN
2 Pages
-
CVM-A Series
7 Pages
-
BM-V
3 Pages
-
PGR Series
2 Pages
-
SGE-PLC Series
2 Pages
-
LM4I/4O-M
2 Pages
-
RGU-10B
2 Pages
-
CEM-C20
2 Pages
-
CEM-C10
2 Pages
-
OPTIM-HYB
2 Pages
-
RVE2-P
2 Pages
-
cSMARTIII
2 Pages
-
AR6
2 Pages
-
CVM-C5
2 Pages
-
FRE
2 Pages
-
MT-FDE
2 Pages
-
RECmaxMP
2 Pages
-
RECmaxLPD
2 Pages
-
CBS4
2 Pages
-
RGU2
2 Pages
-
CIRWATT-B100
2 Pages
-
FEMC-FETC
3 Pages
-
HC
2 Pages
-
BC-V
3 Pages
-
BC-A
3 Pages
-
TL-5
1 Pages
-
CIRWATT-B505
2 Pages
-
CIRWATT B 502
2 Pages
-
CVM Power analyzers
40 Pages
-
Type B
8 Pages
-
MS
1 Pages
-
FLEX-R
1 Pages
-
CIRWATT B 410T
3 Pages
-
TRMC
2 Pages
-
RS2RS
1 Pages
-
ReadWatt
2 Pages
-
Módem Router 3G
2 Pages
-
DIR2
1 Pages
-
computer Smart
2 Pages
-
Smart earth leakage protection
32 Pages
-
ANALOGUE INSTRUMENTS
64 Pages
-
DIGITAL INSTRUMENTS
34 Pages