video corpo

C-FLEX Series
4Pages

{{requestButtons}}

Catalog excerpts

C-FLEX Series - 1

Portable power analyzer m.B C-80 Portable single and three-phase power analyzer O Measurement of the main electrical parameters of a single-phase network, balanced three-phase network and unbalanced three-phase network with neutral O Measurement of energy O Measurement of the THD in A and V O Detects leakage currents and the turning direction of phases O Internal memory to record parameters automatically O Display of the maximum and minimum values of electrical parameters O Reduced size and weight (300g) very robust and easy to use O Auto-detection of clamp 2 x 1,5 V dc (LR6 AA-type batteries) 50 ... 500 Vac 45 ... 65 Hz 2 V (automatic, depending on the clamp) 10% (550 V ac) 10% 200 hours 1 on/off + 7 function keys 7 segments, 3 lines x 4 digits, indication icons L1, L2, L3 / N 4 wires (ID signal -> automatic detection) Circular file (between 1 and 90 min) 172 x 100 x 50 mm 300 g CP 2000/200, CP 1000, CP 500, CP 100, CP 5, CF-5, C-FLEX 200 / 2000 / 20000 O Calculation of the capacity in kvar to compensate the installation O Display of energies compensated with a determined capacitor bank O Creation of harmonic distortion alarms to detect resonances Operating autonomy Keyboard Display Voltage terminals Current clamp connector Record Dimensions Weight Accepted clamps Safety IEC 61010-6-1 Standards IEC 61000-6-3: 1996, Emissions in residential and commercial environments and light industry CISPR 11:1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-4: 1997, Emissions in industrial environments. CISPR 11: 1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-2:1999, Immunity in industrial environments IEC 61000-4-2:1995, Electrostatic discharge IEC 61000-4-3:2002, Radiated electromagnetic field IEC 61000-4-4:1995, Rapid transient bursts IEC 61000-4-5:1995, Shockwaves IEC 61000-4-6:1996, RF in common mode IEC 61000-4-8:1993, Magnetic field at 50 Hz IEC 61000-6-1:1997, Immunity in residential and commercial environments and light industry IEC 61000-4-5:1995, Shockwaves IEC 61010-6-1:2001, Electrical security

Open the catalog to page 1
C-FLEX Series - 2

Portable power analyzer C-80 Portable single and three-phase power analyzer ^Parameters measured^ Balanced Three-phase / Single-phase system Symbol Parameter (unit) Instantaneous Maximum Minimum Voltage V • • • Current A • • - Frequency Active power Reactive power (L and C) All kits include 3 voltage cables + case Apparent power Power factor Cos <p Active energy Power factor (L) Power factor (C) V A PF cos cp W ■ h var■h L var h C ^°jnection^_ Balanced Three-phase System Balanced single-phase system Umbalanced Three-phase System with neutral

Open the catalog to page 2
C-FLEX Series - 3

Clamps C-80 Portable single and three-phase power analyzer Measurement range Nominal frequency Output voltage Dielectric rigidity Scale base error Maximum conductor diameter Maximum busbar Measurement range Measurement range

Open the catalog to page 3
C-FLEX Series - 4

Portable power analyzer Clamps C-80 Portable single and three-phase power analyzer C-FLEX Clamps 20 000 / 2000 / 200 A-120 Longitude sensor Scales Sensitivity in mV Measurement amplitude Bandwidth Accuracy Electrical safety Admissible output overvoltage Ambient conditions 10...20 kHz 1 % Double insulation IEC 1010 - 100 V - Cat III -Degree of contamination 2 600 V (peak factor 1.5) 10...20 kHz 1 % Double insulation IEC 1010 - 100 V - Cat III -Degree of contamination 2 600 V (peak factor 1.5)

Open the catalog to page 4

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4 Pages

  2. TCP2RS+

    4 Pages

  3. LM4I4O-M

    4 Pages

Archived catalogs

  1. Short-Form 2021

    162 Pages

  2. CSB

    2 Pages

  3. RG1M

    2 Pages

  4. RGE

    2 Pages

  5. WGC series

    2 Pages

  6. RGU10

    2 Pages

  7. LVC

    1 Pages

  8. TSA

    2 Pages

  9. R-RE-RBE

    2 Pages

  10. CLZ-FP-HD

    5 Pages

  11. CV

    2 Pages

  12. computer MAX

    2 Pages

  13. LR-LRB

    3 Pages

  14. CR Series

    1 Pages

  15. WI

    2 Pages

  16. MCB

    2 Pages

  17. WGBU

    3 Pages

  18. C80

    4 Pages

  19. AR5L

    9 Pages

  20. TSR

    1 Pages

  21. C-convert

    9 Pages

  22. MEG

    2 Pages

  23. SYNCHROMAX

    3 Pages

  24. UC Series

    3 Pages

  25. SMC-STC

    3 Pages

  26. FMZ-FTZ

    3 Pages

  27. WMC-WTC

    5 Pages

  28. EC-V

    5 Pages

  29. EC-A

    5 Pages

  30. RAPTION 150

    2 Pages

  31. URBAN

    2 Pages

  32. CVM-A Series

    7 Pages

  33. BM-V

    3 Pages

  34. PGR Series

    2 Pages

  35. LM4I/4O-M

    2 Pages

  36. RGU-10B

    2 Pages

  37. CEM-C20

    2 Pages

  38. CEM-C10

    2 Pages

  39. OPTIM-HYB

    2 Pages

  40. RVE2-P

    2 Pages

  41. cSMARTIII

    2 Pages

  42. AR6

    2 Pages

  43. CVM-C5

    2 Pages

  44. FRE

    2 Pages

  45. MT-FDE

    2 Pages

  46. RECmaxMP

    2 Pages

  47. RECmaxLPD

    2 Pages

  48. CBS4

    2 Pages

  49. RGU2

    2 Pages

  50. CIRWATT-B100

    2 Pages

  51. FEMC-FETC

    3 Pages

  52. HC

    2 Pages

  53. BC-V

    3 Pages

  54. BC-A

    3 Pages

  55. TL-5

    1 Pages

  56. CIRWATT-B505

    2 Pages

  57. Type B

    8 Pages

  58. MS

    1 Pages

  59. FLEX-R

    1 Pages

  60. TRMC

    2 Pages

  61. RS2RS

    1 Pages

  62. ReadWatt

    2 Pages

  63. DIR2

    1 Pages