Portable power analyzer m.B C-80 Portable single and three-phase power analyzer O Measurement of the main electrical parameters of a single-phase network, balanced three-phase network and unbalanced three-phase network with neutral O Measurement of energy O Measurement of the THD in A and V O Detects leakage currents and the turning direction of phases O Internal memory to record parameters automatically O Display of the maximum and minimum values of electrical parameters O Reduced size and weight (300g) very robust and easy to use O Auto-detection of clamp 2 x 1,5 V dc (LR6 AA-type batteries) 50 ... 500 Vac 45 ... 65 Hz 2 V (automatic, depending on the clamp) 10% (550 V ac) 10% 200 hours 1 on/off + 7 function keys 7 segments, 3 lines x 4 digits, indication icons L1, L2, L3 / N 4 wires (ID signal -> automatic detection) Circular file (between 1 and 90 min) 172 x 100 x 50 mm 300 g CP 2000/200, CP 1000, CP 500, CP 100, CP 5, CF-5, C-FLEX 200 / 2000 / 20000 O Calculation of the capacity in kvar to compensate the installation O Display of energies compensated with a determined capacitor bank O Creation of harmonic distortion alarms to detect resonances Operating autonomy Keyboard Display Voltage terminals Current clamp connector Record Dimensions Weight Accepted clamps Safety IEC 61010-6-1 Standards IEC 61000-6-3: 1996, Emissions in residential and commercial environments and light industry CISPR 11:1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-4: 1997, Emissions in industrial environments. CISPR 11: 1997 MOD, Radiated (CISPR 22: 1997 MOD-Class A) IEC 61000-6-2:1999, Immunity in industrial environments IEC 61000-4-2:1995, Electrostatic discharge IEC 61000-4-3:2002, Radiated electromagnetic field IEC 61000-4-4:1995, Rapid transient bursts IEC 61000-4-5:1995, Shockwaves IEC 61000-4-6:1996, RF in common mode IEC 61000-4-8:1993, Magnetic field at 50 Hz IEC 61000-6-1:1997, Immunity in residential and commercial environments and light industry IEC 61000-4-5:1995, Shockwaves IEC 61010-6-1:2001, Electrical security

 Open the catalog to page 1
C-FLEX Series-2

Portable power analyzer C-80 Portable single and three-phase power analyzer ^Parameters measured^ Balanced Three-phase / Single-phase system Symbol Parameter (unit) Instantaneous Maximum Minimum Voltage V • • • Current A • • - Frequency Active power Reactive power (L and C) All kits include 3 voltage cables + case Apparent power Power factor Cos <p Active energy Power factor (L) Power factor (C) V A PF cos cp W ■ h var■h L var h C ^°jnection^_ Balanced Three-phase System Balanced single-phase system Umbalanced Three-phase System with neutral

 Open the catalog to page 2
C-FLEX Series-3

Clamps C-80 Portable single and three-phase power analyzer Measurement range Nominal frequency Output voltage Dielectric rigidity Scale base error Maximum conductor diameter Maximum busbar Measurement range Measurement range

 Open the catalog to page 3
C-FLEX Series-4

Portable power analyzer Clamps C-80 Portable single and three-phase power analyzer C-FLEX Clamps 20 000 / 2000 / 200 A-120 Longitude sensor Scales Sensitivity in mV Measurement amplitude Bandwidth Accuracy Electrical safety Admissible output overvoltage Ambient conditions 10...20 kHz 1 % Double insulation IEC 1010 - 100 V - Cat III -Degree of contamination 2 600 V (peak factor 1.5) 10...20 kHz 1 % Double insulation IEC 1010 - 100 V - Cat III -Degree of contamination 2 600 V (peak factor 1.5)

 Open the catalog to page 4

All CIRCUTOR catalogs and technical brochures

  1. BC48 15V

    4  Pages

  2. TCP2RS+

    4  Pages

  3. LM4I4O-M

    4  Pages

Archived catalogs

  1. DIR2

    1  Page

  2. ReadWatt

    2  Pages

  3. RS2RS

    1  Page

  4. FLEX-R

    1  Page

  5. MS

    1  Page

  6. Type B

    8  Pages

  7. CIRWATT B 502

    2  Pages

  8. CIRWATT-B505

    2  Pages

  9. TL-5

    1  Page

  10. BC-A

    3  Pages

  11. BC-V

    3  Pages

  12. HC

    2  Pages

  13. FEMC-FETC

    3  Pages

  14. CIRWATT-B100

    2  Pages

  15. RGU2

    2  Pages

  16. CBS4

    2  Pages

  17. RECmaxLPD

    2  Pages

  18. RECmaxMP

    2  Pages

  19. MT-FDE

    2  Pages

  20. FRE

    2  Pages

  21. CVM-C5

    2  Pages

  22. AR6

    2  Pages

  23. cSMARTIII

    2  Pages

  24. RVE2-P

    2  Pages

  25. OPTIM-HYB

    2  Pages

  26. CEM-C10

    2  Pages

  27. CEM-C20

    2  Pages

  28. RGU-10B

    2  Pages

  29. LM4I/4O-M

    2  Pages

  30. TRMC

    2  Pages

  31. PGR Series

    2  Pages

  32. BM-V

    3  Pages

  33. CVM-A Series

    7  Pages

  34. URBAN

    2  Pages

  35. RAPTION 150

    2  Pages

  36. EC-A

    5  Pages

  37. EC-V

    5  Pages

  38. WMC-WTC

    5  Pages

  39. FMZ-FTZ

    3  Pages

  40. SMC-STC

    3  Pages

  41. UC Series

    3  Pages

  42. SYNCHROMAX

    3  Pages

  43. MEG

    2  Pages

  44. C-convert

    9  Pages

  45. TSR

    1  Page

  46. AR5L

    9  Pages

  47. C80

    4  Pages

  48. WGBU

    3  Pages

  49. WI

    2  Pages

  50. CR Series

    1  Page

  51. LR-LRB

    3  Pages

  52. computer MAX

    2  Pages

  53. CV

    2  Pages

  54. CLZ-FP-HD

    5  Pages

  55. R-RE-RBE

    2  Pages

  56. LVC

    1  Page

  57. RGU10

    2  Pages

  58. WGC series

    2  Pages

  59. RGE

    2  Pages

  60. RG1M

    2  Pages

  61. CSB

    2  Pages

  62. MCB

    2  Pages

  63. TSA

    2  Pages

  64. Short-Form 2021

    162  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.