Catalog excerpts
Portable power analyzer Portable single and three-phase power analyzer Description }} Measures all of the main electrical parameters of an electricity network }} Measurement in true root mean square }} Built-in energy meter }} With 4 voltage channels and 4 current channels (AR5-L) }} Configurable auto-trigger, depending on the parameters required }} Languages: Spanish and English }} Large backlit LCD display }} CAT III 600 V (EN 61010). UL Certificate }} Display of up to 30 electrical parameters on the screen }} Small size and reduced weight, only 800 g }} Independent files for each measurement }} Including the powerful analysis software: POWER VISION PLUS }} Configurable with menus }} Optional operation with no external power supply, with an autonomy of up to 8 hours }} RS-232 Communications with PC }} Clamp auto-detection }} Auto-selection of parameters stored }} Calculation of the time remaining until the memory is full }} Linear or rotating memory (depending on the configuration) Features AR5-L Power supply circuit Through an external power supply unit Operating temperature 80 % for temperatures under 31 ºC, with a linear decrease down to 50 % at 40 ºC Measurement circuit Contamination level Voltage circuit Measurement range In accordance with the clamp, 0.01 A...20 kA Voltage and current transformation ratios Measurement units Automatic change of scale Internal memory Accuracy class (*) Voltage Active power Power factor Build features Reinforced insulation Keyboard / Display Current clamp connector
Open the catalog to page 1Portable power analyzer Portable single and three-phase power analyzer }} Complete study of the installation where the analyzer is capable of gathering different types of records: harmonics, disturbances, meter verification, transients, flicker, etc. Category III - 600 V, in accordance with 61010 Standards EN 61000-3-2 (1995), Harmonics EN 61000-3-3 (1995), Voltage fluctuations EN 61000-6-4 (2002), Industrial emissions EN 55011 (1994), Driven (EN 52022 – Class B) EN 55011 (1994), Radiated (EN 55022 – Class A) EN 61000-6-2 (2022), Industrial immunity EN 61000-4-2 (1995), Electrostatic...
Open the catalog to page 2Portable power analyzer Portable single and three-phase power analyzer Parameters measured Three-phase system, 3 wires Three-phase system, 4 wires Symbol (unit) Three-phase value phase-neutral voltage Neutral current (only AR5-L) Active power Apparent power Power factor Active energy Voltage harmonics Three-phase value phase-phase voltage Active power Apparent power Power factor Active energy Voltage harmonics Current harmonics Current harmonics on neutral Symbol (unit) Current harmonics Single-phase system Two-phase System Parameter Symbol (unit) Symbol (unit) phase-phase voltage...
Open the catalog to page 3Portable power analyzer Programs Portable single and three-phase power analyzer Programs Description Updating harmonics Detection of network disturbances PERTURB Program CHECK METER, meter verification system Optic fibre sensor, shunts and CHECK METER program included Optical check meter kit FAST CHECK, motor start-up Fast Program LEAK METER, detection and analysis of leakages Leak Program FILE VISION, display of files in AR5-L Memory capacity example: In the Energy program, if you record 30 network parameters, with a registration period of 15 minutes, you obtain an autonomy of 80 days of...
Open the catalog to page 4Portable power analyzer Portable single and three-phase power analyzer Network quality - Disturbances Program applications: }} Detection of interruptions, gaps, microcuts, peaks, etc. }} Adjustment of the sensitivity for the capture of different types of disturbances }} Information about the number of disturbances detected }} Applications }} Check the effect of switching a load over various points of the installation }} Take "x-rays" of any installation with an AR5-L unit and a PC, in order to know everything about a supply network: xx Evolution of the wave shape xx Display of an...
Open the catalog to page 5Portable power analyzer Portable single and three-phase power analyzer Check-Meter The program can be used to: }} Check the measurements of electronic and mechanical meters }} Carry out the tests with no energy cuts }} Carry out 30-second long tests }} Determine the error in active energy or power factor meters }} Programmed setup and percentage error on a single screen }} to 4000 records can be created Up }} Numerical table }} Export to .bmp format or to the clampboard. Optical reader kit }} electronic meters or meters with veriFor fication LED }} Optic fibre cable used to check meters }}...
Open the catalog to page 6Portable power analyzer Portable single and three-phase power analyzer File Vision }} On-site verification of records }} Display of records, with no need for a PC }} screen has a cursor that indicates the The position of the value of the variable selected, in terms of record time and parameter }} Auto-scalable axis of the parameter (adapted to the maximum and minimum values of all records }} Permanent display of 32 records on the screen }} Display of the maximum and minimum value of the records }} You can browse through records easily and quickly }} Variables represented by the different...
Open the catalog to page 7Portable power analyzer Portable single and three-phase power analyzer Clamps Measurement range Nominal frequency Output voltage Dielectric rigidity Maximum conductor diameter Maximum busbar Scale base error Description / Code
Open the catalog to page 8Portable power analyzer Portable single and three-phase power analyzer Clamps C-FLEX 20 000 / 2 000 / 200 A-45 Longitude sensor Scale 200 or 100: 10 mV / A Scale 2000 or 1000: 1 mV / A Scale 20k or 10k: 0,1 mV / A Measurement amplitude Electrical safety Double insulation IEC 1010 - 100 V - Cat III Degree of contamination 2 Admissible output overvoltage Ambient conditions Temperature Clamps C-FLEX 20 000 / 2 000 / 200 A-80 Longitude sensor Longitude sensor Scale 200 or 100: 10 mV / A Scale 2000 or 1000: 1 mV / A Scale 20k or 10k: 0,1 mV / A Scale 200 or 100: 10 mV / A Scale 2000 or 1000: 1...
Open the catalog to page 9All CIRCUTOR catalogs and technical brochures
-
Filtering solutions
16 Pages
-
BC48 15V
4 Pages
-
DCB, Digital instruments
2 Pages
-
WRU-10, Smart protection
2 Pages
-
REC4, Self-reclosing RCCB
8 Pages
-
Electric Vehicle Charging
8 Pages
-
Solutions for AMI systems
20 Pages
-
Solutions for ISO 50001
12 Pages
-
TCP2RS+
4 Pages
-
LM4I4O-M
4 Pages
-
Solar photovoltaic canopies
8 Pages
-
Solutions for Self-consumption
16 Pages
-
MYeBOX Connected to efficiency
12 Pages
Archived catalogs
-
Short-Form 2021
162 Pages
-
CSB
2 Pages
-
RG1M
2 Pages
-
RGE
2 Pages
-
WGC series
2 Pages
-
RGU10
2 Pages
-
LVC
1 Pages
-
TSA
2 Pages
-
R-RE-RBE
2 Pages
-
CLZ-FP-HD
5 Pages
-
CV
2 Pages
-
computer MAX
2 Pages
-
LR-LRB
3 Pages
-
CR Series
1 Pages
-
WI
2 Pages
-
MCB
2 Pages
-
WGBU
3 Pages
-
C80
4 Pages
-
TSR
1 Pages
-
C-convert
9 Pages
-
MEG
2 Pages
-
SYNCHROMAX
3 Pages
-
UC Series
3 Pages
-
SMC-STC
3 Pages
-
FMZ-FTZ
3 Pages
-
WMC-WTC
5 Pages
-
EC-V
5 Pages
-
EC-A
5 Pages
-
RAPTION 150
2 Pages
-
URBAN
2 Pages
-
CVM-A Series
7 Pages
-
BM-V
3 Pages
-
PGR Series
2 Pages
-
SGE-PLC Series
2 Pages
-
LM4I/4O-M
2 Pages
-
RGU-10B
2 Pages
-
CEM-C20
2 Pages
-
CEM-C10
2 Pages
-
OPTIM-HYB
2 Pages
-
RVE2-P
2 Pages
-
cSMARTIII
2 Pages
-
AR6
2 Pages
-
CVM-C5
2 Pages
-
FRE
2 Pages
-
MT-FDE
2 Pages
-
RECmaxMP
2 Pages
-
RECmaxLPD
2 Pages
-
CBS4
2 Pages
-
RGU2
2 Pages
-
CIRWATT-B100
2 Pages
-
FEMC-FETC
3 Pages
-
HC
2 Pages
-
BC-V
3 Pages
-
BC-A
3 Pages
-
TL-5
1 Pages
-
CIRWATT-B505
2 Pages
-
CIRWATT B 502
2 Pages
-
CVM Power analyzers
40 Pages
-
Type B
8 Pages
-
C-FLEX Series
4 Pages
-
MS
1 Pages
-
FLEX-R
1 Pages
-
CIRWATT B 410T
3 Pages
-
TRMC
2 Pages
-
RS2RS
1 Pages
-
ReadWatt
2 Pages
-
Módem Router 3G
2 Pages
-
DIR2
1 Pages
-
computer Smart
2 Pages
-
Smart earth leakage protection
32 Pages
-
ANALOGUE INSTRUMENTS
64 Pages
-
DIGITAL INSTRUMENTS
34 Pages