video corpo

Online Odor monitoring : vigi e-nose analyzer
1 / 4Pages

Catalog excerpts

Online Odor monitoring : vigi e-nose analyzer - 1

Online Gas Analyzer Experts Online Odor Monitoring vigi e-nose analyzer New e-nose GC based technology . H2S . MERCAPTANS . SULFIDES . ODORANTS . ODOR . NH3

Open the catalog to page 1
Online Odor monitoring : vigi e-nose analyzer - 2

vigi e-nose analyzer Odor monitoring with speciation of Sulfurs & VOCs at ppb levels Revolutionary network of field-based electronic nose • Most sensitive e-nose of the market with detection lower than what human nose can detect (as low as 1 ppb for H2S) • Capabilities to deploy non-limited number of units on industrial site • Unique technology able to monitor tVOCs, Odor unit, Sulfurs speciation • Odor intensity monitoring by default without training based on odor thresholds • Odor unit concentration calculation when trained with EN13725 or ASTM 679-E04 using dynamic olfactometry •...

Open the catalog to page 2
Online Odor monitoring : vigi e-nose analyzer - 3

vigi e-nose analyzer Network for continuous monitoring of odor & pollutant gases CONTINUOUS MEASUREMENT OF CONCENTRATIONS • Odor, in odor unit (EN 13725, ASTM E679) • Pollutant gases, in ppb or ppm : tVOCs or NH3, Sulfurs (H2S / Mercaptans : MeSH, EthylSH, Pro-pylSH/ Sulfides : DMS / DMDS ) at ppb levels DYNAMIC DISPERSION PLUME IN THE NEIGHBORHOOD • Dynamic 3D mapping of dispersion plumes • Calculations of concentrations in the vicinity of the site(s) • Automated dispersion reports REAL-TIME ALERTS • Configurable alert thresholds per molecule, odor or group of molecule • Notification by...

Open the catalog to page 3
Online Odor monitoring : vigi e-nose analyzer - 4

Parameters measured Technologies Detection limits Range Relative standard deviation Cycle Time Supervisor Communication Power Supply Electrical Consumption Dimensions and weights Norms and certifications Sulfurs (H2S, MeSH, EtSH, Propyl-SH, DMS, DMDS), Odor concentration and Total Sulfur, tVOCs including NH3, Amines, Sulfurs, BTEX and more Mixed technologies with autoGC with electrochemical wet cell with reservoir for long term stability & PID detector Down to 1 ppb for H2S, DMS, MM, EM, SO2 50 ouE/m3 limited of the olfactometer Adjustable depending on application: 0/10 or 0/100 or 0/1000...

Open the catalog to page 4

All CHROMATOTEC catalogs and technical brochures

  1. chromaTCD

    2 Pages

  2. MEDOR® Exd

    2 Pages

  3. airmo H-CHO

    2 Pages

  4. airmOzone

    4 Pages

  5. airmo S

    2 Pages

  6. Medor Exp

    4 Pages

  7. Key products

    2 Pages

  8. chromaCO

    1 Pages

  9. airmoTWA

    2 Pages

  10. airmoTHM