Product Overview
The document outlines the technical specifications and capabilities of the Vigi E-Nose, an advanced odor and VOCs speciation monitoring solution. It is designed for ultra-sensitive odor detection and real-time environmental supervision across industrial sites.

Key Specifications
  • Measures a wide range of compounds including sulfurs, VOCs, amines, and more, with speciation capabilities.
  • Integrated sensors for Cl2, N2O, CH4, CO2, NH3, and others upon request.
  • Utilizes mixed technologies such as autoGC, electrochemical wet cell, PID detector, GC-FID, GC-MS, NDIR, sensors, FTUV, and HPLC.
  • Detection limits down to 1 ppb for H2S and 10 ppt for Benzene.
  • Relative standard deviation (RSD) of less than 3% on concentration over 48 hours.

Performance and Features
  • Real-time mapping of odor sources and plume movements.
  • Scalable network architecture for extensive site coverage.
  • Automatic calibration and validation with integrated permeation tubes.
  • Zero drift and no cross-interference due to chromatographic separation.
  • Remote access and control via Ethernet and 4G modem.

Operational Capabilities
  • Configurable thresholds and automatic alarms for real-time alerts.
  • Continuous 3D visualization of odor dispersion and automated reporting.
  • Automatic activation/deactivation of deodorization systems based on odor load.
  • Capable of monitoring multiple points simultaneously.

Physical and Power Specifications
  • Mean power consumption of 100 W with options for 230V 60Hz or 115V 50Hz power supply.
  • Available in rack, wall-mounted box, and shelter configurations with specified dimensions and weights.

Conclusion
The Vigi E-Nose offers a comprehensive solution for odor and VOC monitoring, providing precise source identification and site-wide coverage with advanced real-time mapping and control features.
See more

Catalog excerpts

CHROMATOTEC Brochure: Vigi E-Nose, Online Odor & VOCs Speciation Monitoring Solutions-1

Product technical specifications Designation Parameters measured • Sulfurs with speciation (H2S, MeSH, EtSH, Propyl-SH, DMS, DMDS), Odor concentration and Total Sulfur • T-VOCs including NH3, Amines, Sulfurs, BTEX and more • VOCs with speciation such as : aldehydes, ketones and others • Amines with speciation • With integrated sensors : Cl2, N2O, CH4, CO2, NH3 and others on request Technologies Mixed technologies with autoGC with electrochemical wet cell with reservoir for long term stability & PID detector, GC-FID, GC-MS, NDIR, sensors, FTUV, HPLC Detection limits • Down to 1 ppb for H2S, DMS, MM, EM, SO2 Range Adjustable depending on application : 0/10 or 0/100 or Relative standard • RSD < 3% on concentration over 48 h deviation • RSD < 0,5 % on retention time over 48 h • VOCs from 2 to 30 minutes Communication Power Supply Embeded computer Windows® based with LCD display & 128 GB of Hardware storage on SSD memory Ethernet for remote control, 4G modem Vigi E-Nose Online Odor & VOCs Speciation Monitoring Solutions Electrical Consumption Mean power consumption 100 W Wall mounted box: Shelter: Dimensions and weights Rack: 19 (5U)

 Open the catalog to page 1
CHROMATOTEC Brochure: Vigi E-Nose, Online Odor & VOCs Speciation Monitoring Solutions-2

Vigi e-nose Solutions Intelligent Odor Management Advanced autoGC platform delivering continuous ppb/ppt-level odor and VOCs speciation, enabling precise source identification and site-wide monitoring. Real-time odor mapping, threshold-based alerts and automated process control for reliable environmental supervision across industrial facilities. Ultra-Sensitive Odor Detection • Lower detection limits than human olfactory thresholds (e.g., H2S < 1 ppb) • Accurate quantification of odor intensity without prior training • True chemical speciation: sulfurs, mercaptans, VOCs, aldehydes, ketones, amines,...

 Open the catalog to page 2

All CHROMATOTEC catalogs and technical brochures

  1. airmoPURE 2L

    2  Pages

  2. airmoPURE

    2  Pages

  3. airmoCAL

    2  Pages

  4. DET H2O

    2  Pages

  5. microF

    2  Pages

  6. microVOC

    2  Pages

  7. vigi e-nose

    2  Pages

  8. THT MEDOR

    2  Pages

  9. H2S MEDOR

    2  Pages

  10. trsMEDOR

    2  Pages

  11. airmoMEDOR

    2  Pages

  12. energyMEDOR

    2  Pages

  13. chromaPID

    2  Pages

  14. chromaDID

    2  Pages

  15. chromaS COS

    2  Pages

  16. chromEnergy

    2  Pages

  17. chromaTCD

    2  Pages

  18. chromARGON

    2  Pages

  19. chromaFID

    2  Pages

  20. chroma CO

    2  Pages

  21. auto GCMS 866

    2  Pages

  22. airmoVOC WMS

    2  Pages

  23. airTOXIC WMS

    2  Pages

  24. airTOXIC

    2  Pages

  25. airmoVOC C2C6

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.