Measurement Principle: The MEDOR® Ex system is designed for the continuous, online analysis of sulfur compounds in natural and biogas feeds. It utilizes gas chromatography (GC) technology to analyze compounds such as H2S, methyl mercaptan, ethyl mercaptan, and other odorant blends.
Specifications: The system offers a detection limit down to 1 ppb for H2S and a measuring range from 1 ppb to 1000 ppm. It features an automatic tank filling mechanism and is housed in a stainless steel purged cabinet, certified for ATEX Zone 1 and 2, or CSA International for Class 1 Division 2 areas.
Technical Specifications: The analyzer cabinet dimensions are 540mm x 475mm x 272mm, with a net weight of 65 kg. It operates on a power supply of 230V AC / 50-60Hz with a mean power consumption of 150 VA. The system uses nitrogen or air as carrier gas and includes an internal calibration system.
Norms & Certifications: The MEDOR® Ex complies with ASTM D7493-22, D5504-20, ISO 19739:2004, DIN 51855/7, and ASTM Type 1 Standard. It is suitable for hazardous zones with ATEX or IECEx certification.
Features & Benefits: The system provides full speciation of analyzed compounds, ensuring no thermal conversion is required. It is equipped with Vistachrom software for easy operation, data processing, and alarm management. The system is low maintenance, with components like capillary columns and the electrochemical detection system having lifetimes exceeding 10 years.
Applications: The MEDOR® Ex is used for odorization applications, process monitoring in gas cleaning and desulfurization, and pipeline quality control. It ensures accurate monitoring and control of sulfur content in various gas types, providing security and efficiency in gas processing and transport.
See more

Catalog excerpts

CHROMATOTEC Brochure: MEDOR® Ex-1

Technical Specifications MEDOR® Ex Designation Measurement Principle Wet cell with reservoir for long term stability Sulfur compounds analysis Total or speciated compound results. H2S, methyl mercaptan, ethyl mercaptan, THT, TBM, NPM, SBM, IPM, DMS, DMDS are all analyzed by the MEDOR® Ex COS in option Detection limits Measuring Range Cycle Time H2S/TOS/TS: 120 seconds Speciation + Total Sulfurs: 600 seconds Relative standard deviation < 3 % over 48 h period on concentration < 0,5 % over 48 h period on retention time Data Management Module 4-20 mA with 4 output and 0 mA for default instrument; MODBUS RTU/RS485; ethernet storage of all results on internal SSD memory Electrical Power Supply & Consumption 230V AC / 50-60Hz (115V AC / 50-60Hz) Mean power consumption 150 VA 24V DC in option Carrier gas : N2 or Air (3 Bar): 4 ml/min Internal calibration: 50 ml/min Pneumatic valve: 90 ml/commutation Sample gas: (1 Bar): 10 l/h Automatic tank filling for MEDOR detector Analyzer Cabinet: 540mm x 475mm x 272mm (H x W xD) Net Weight: 65 kg (for one single module) Norms & Certifications Fully compliant with ASTM D7493-22, D5504-20, ISO 19739:2004, DIN 51855/7, and ASTM Type 1 Standard Class 1 Division 2 T4 ATEX : ATEX or IECEx: Zone 1 and 2 - II 2 G Exp and Exd xb IIC T4 Gb Ta=Up to -20°C to +55°C) MEDOR® Ex ONLINE ANALYSIS OF SULFUR COMPOUNDS ATEX / IECEx / C1D2 / C1 D

 Open the catalog to page 1
CHROMATOTEC Brochure: MEDOR® Ex-2

Features & benefits of the MEDOR® Ex system Online monitoring of sulfurs in Hazardous zones The MEDOR® Ex from CHROMATOTEC® offers continuous, online analysis of sulfur compounds from concentrations as low as 1 ppb in natural and biogas feeds. The compounds analyzed by the system include all naturally occurring sulfurs such as H2S, methyl and ethyl mercaptan as well as all odorant blends. The system uses proven GC technology developed and improved over 35 years for odorization, quality and safety applications in a wide variety of processes. The quality and performance of our systems have been...

 Open the catalog to page 2

All CHROMATOTEC catalogs and technical brochures

  1. airmoPURE 2L

    2  Pages

  2. airmoPURE

    2  Pages

  3. airmoCAL

    2  Pages

  4. DET H2O

    2  Pages

  5. microF

    2  Pages

  6. microVOC

    2  Pages

  7. vigi e-nose

    2  Pages

  8. THT MEDOR

    2  Pages

  9. H2S MEDOR

    2  Pages

  10. trsMEDOR

    2  Pages

  11. airmoMEDOR

    2  Pages

  12. energyMEDOR

    2  Pages

  13. chromaPID

    2  Pages

  14. chromaDID

    2  Pages

  15. chromaS COS

    2  Pages

  16. chromEnergy

    2  Pages

  17. chromaTCD

    2  Pages

  18. chromARGON

    2  Pages

  19. chromaFID

    2  Pages

  20. chroma CO

    2  Pages

  21. auto GCMS 866

    2  Pages

  22. airmoVOC WMS

    2  Pages

  23. airTOXIC WMS

    2  Pages

  24. airTOXIC

    2  Pages

  25. airmoVOC C2C6

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.