Case Study - Source Water - airmoVOC WMS
1 /2Pages

Case Study - Source Water - airmoVOC WMS

Case Study - Source Water - airmoVOC WMS
1 /2Pages

Catalog excerpts

Case Study - Source Water - airmoVOC WMS-1

Case Study N°WMS2 – airmoVOC WMS– updated: 24.09.21 Analysis and monitoring of source water quality Context & Challenges The water may contain chemical species such as Benzene, Toluene, Ethylbenzene and Xylene, as well as other VOCs, including halogens. These compounds can result from various treatment processes, including iron removal. It is made by reaction with Ozone which also reacts with various compounds present in the water, such as Bromides and Chlorides, to form Bromoform and Chloroform. Subject to regulation, these levels, although minimal, must be followed closely, before and after the process. Chromatotec® Solutions Chromatotec® has developed a solution equipped with an MCERTS certified GC FID, analyzing VOCs dissolved in liquids, by purge & trap sampling system (according to the EPA 502-2 standard) or headspace. This system makes the extraction of VOCs from a liquid and analyze them by a GC, in order to identify and quantify the contaminantes in the water with BTEX and light SVOCs, at very low levels (µg/L or ppb). The airmoVOC WMS can both be adapted to take liquid samples in standing water or with a continuous and controlled flow. This all in one solution is composed of an airmoVOC analyzer, hydrogen generators and zero air catalyzer, an internal calibration allowing to obtain reliable results, in real time and without human intervention. The airmoVOC WMS is used in the water markets of the food processing, the pharmaceutical industry, cosmetics and perfumery and also in the analysis of drinking water, beverages and drinking water, surfaces, food liquids (milk, soda, wines, spirits…). airmoVOC WMS [email protected] www.chromatotec.com Online Gas and Liquid Analyzer

 Open the catalog to page 1
Case Study - Source Water - airmoVOC WMS-2

Case Study N°WMS2 - airmoVOC WMS- updated: 24.09.21 Ease of use ■ Waterproof cabinet, protected from wet projections and aggressive atmospheres ■ No auxiliary gas needed for operation and calibration ■ Hydrogen, nitrogen and air consumption ■ Integrated sampling pump enables analysis of atmosphere pressurized sample ■ Automatic internal calibration with certified permeation tubes at ppb or ppm level Data are automatically collected by Vistachrom software and interface. Datas like concentrations, retention times, analyzer status ... can be transferred by Modbus protocol or 4-20mA analog output,...

 Open the catalog to page 2

All CHROMATOTEC catalogs and technical brochures

  1. airmoPURE 2L

    2  Pages

  2. airmoPURE

    2  Pages

  3. airmoCAL

    2  Pages

  4. DET H2O

    2  Pages

  5. microF

    2  Pages

  6. microVOC

    2  Pages

  7. vigi e-nose

    2  Pages

  8. THT MEDOR

    2  Pages

  9. H2S MEDOR

    2  Pages

  10. trsMEDOR

    2  Pages

  11. airmoMEDOR

    2  Pages

  12. energyMEDOR

    2  Pages

  13. chromaPID

    2  Pages

  14. chromaDID

    2  Pages

  15. chromaS COS

    2  Pages

  16. chromEnergy

    2  Pages

  17. chromaTCD

    2  Pages

  18. chromARGON

    2  Pages

  19. chromaFID

    2  Pages

  20. chroma CO

    2  Pages

  21. auto GCMS 866

    2  Pages

  22. airmoVOC WMS

    2  Pages

  23. airTOXIC WMS

    2  Pages

  24. airTOXIC

    2  Pages

  25. airmoVOC C2C6

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.