Group: Chromatotec Group
Catalog excerpts
Online Gas Analyzer Experts ONLINE ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY autoGC-MS Turnkey Stand-alone Solution Monitoring up to 123 compounds with expertise in ambient air from cities or industrial areas OZONE PRECURSORS : VOCs FROM PAMS, TO14, TO15, OVOCs INCLUDING BTEX, HALOGENATED VOCs DIOXINS PRECURSORS AND SOLVENTS S VOCs: PAHs, PCBs
Open the catalog to page 1The airmOzone + DET QMS from CHROMATOTEC® offers continuous, online analysis of volatile organic compounds from concentrations as low as 1 ppt in indoor or outdoor ambient air. All compounds from C2 to C12 are analyzed by the autoGC MS and unknown compounds are identified by our VistaMS software comparing automatically obtained mass spectrum to embedded NIST library down to sub ppb level. With specific configuration, linear hydrocarbons up to C16 or gaseous PAHs are analyzed using airmoVOC C6CI6 expert + DET QMS. The system uses proven autoGC technology and process quadrupole mass...
Open the catalog to page 2Features & Benefits FID and MS detection Internal multipoint calibration system The use of our micro FID and process MS ensure no interference of results and high expertise by All airmOzone + DET QMS systems are supplied with combining the long term stability and linearity of FID airmoCAL MFC: internal calibration by permeation and the expertise in term of identification of the MS. tubes, cylinder inlet and MFC for dilution of the The only gases required by the system are Hydrogen cylinder or the permeation tubes. Results are thus and zero air provided by inbuilt ultra-high purity...
Open the catalog to page 3Molecule range Technologies Dimensions Detectors Detection limits Range RSD Cycle Time Analysis Mode Results Communication Supervisor Carrier gas / Gas supply per analyzer Power Supply AMERICA / US CHROMATOTEC Inc. Houston - USA Technical Specifications Capabilities of analysis: - up to 123 VOCs including PAMS 56, TO14, TO 15 molecule lists - Alkanes, hydrocarbons and Polyaromatics Hydrocarbons (PAHs) with airmoVOC C6C16/ MS configuration - Oxygenated VOCs in addition to current VOCs Automatic Gas Chromatography (autoGC) and Process MS 19'' cabinet : Height: 1800 mm (analyzer alone) /...
Open the catalog to page 4All CHROMATOTEC catalogs and technical brochures
-
Sampling solutions
2 Pages
-
Online Gas Analyzer Experts
4 Pages
-
chromaTCD
2 Pages
-
CHROMA THC 2MIN
2 Pages
-
airTOXICBTX PID
2 Pages
-
airmoVOC BTEX MCERTS
2 Pages
-
PURE GASES QUALITY CONTROL
1 Pages
-
MEDOR® Exd
2 Pages
-
airmo H-CHO
2 Pages
-
airmoVOC C6-C16
2 Pages
-
airmo S
2 Pages
-
Expertise in Online GC
4 Pages
-
Medor Exp
4 Pages
-
General Catalogue
4 Pages
-
Company Profile
2 Pages
-
Key products
2 Pages
-
Case Study Terpenes analysis
2 Pages
-
chromaCO
1 Pages
-
airmoTWA
2 Pages
-
airmoTHM
2 Pages
-
airmoVOC C6C12
2 Pages
-
airmoVOC C2C6
2 Pages