Chloride Trinergy - 1

High Power Modular Scalable UPS With Three Dynamic Functioning Modes Network Power

Open the catalog to page 1
Chloride Trinergy - 2

Emerson Network Power, a division of Emerson, is a global company that combines technology with design to supply innovative solutions for the benefit of its customers. Emerson Network Power protects and optimizes critical infrastructure for data centers, communications networks, healthcare and industrial facilities. Emerson Network Power’s broad technology base and global expertise support a full spectrum of enterprise-wide solutions for today’s vital business needs. Regardless of your size, More standardization, you can’t afford for your so you don’t need further critical business systems...

Open the catalog to page 2
Chloride Trinergy - 4

mode transitioning for first maximum load protection. • Power interface on bypass • Real-time input power mode transitioning Trinergy's revolutionary architecture comes from industry standard functioning configurations for the first time • Maximum Power • Maximum Energy High Efficiency and Power Trinergy's unique combination of technology allows it to monitor before intelligently selecting the functioning mode best suited to Trinergy's ability to choose the most efficient operating mode based on the different network conditions ensures that the supply to the load remains in optimum...

Open the catalog to page 4
Chloride Trinergy - 5

Dynamic Functioning Modes Manual Bypass Static Bypass Power interface Inverter Output Maximum Power Control (VFI) provides the highest level of power conditioning and protects the load from all electrical network disturbances. Manual Bypass Static Bypass Power interface Inverter Output Maximum Energy Saving (VFD) detects when conditioning is not required and allows the energy flow to pass through the bypass line. Manual Bypass Static Bypass Power interface Inverter Output Conditioning (VI) compensates the load THDi, PF and main sags and swells. Dynamic Modes

Open the catalog to page 5
Chloride Trinergy - 6

Minimized Total Cost Of Ownership Maximized Savings Trinergy™’s design features and outstanding efficiency up to 99%, greatly minimize the total cost of ownership from installation through to operation: Extraordinary Savings The modular architecture of the Trinergy UPS allows for great advantages in terms of installation: Reduced size of electrical infrastructure Reduced size of circuit protection devices Reduced cabling Trinergy features unitary input Power Factor and low content of harmonics providing full compatibility with gensets and greatly contributing to reduced installation and...

Open the catalog to page 6
Chloride Trinergy - 7

High Efficiency Trinergy™ 's unique architecture and technology have been purposely developed to enhance Able to discriminate between the different network input conditions and select the best functioning mode in relation to the disturbance, Trinergy can achieve maximum energy savings by using only the necessary amount of energy required to provide the best output power quality and conditioning to Advantages Include: • Premium energy savings via transformer free technology and Trinergy's algorithm • Quietest UPS in its power range • Maximized battery life with Advanced Battery Care (ABC) •...

Open the catalog to page 7
Chloride Trinergy - 8

Sizing Your System Vertical modularity Service a 200 kW module while the UPS system continues to protect your load. Orthogonal modularity Up to 8 units in parallel. I/O Box Major interface for connectivity and power connections. the stacked drawers in each module can be individually extracted for service purposes while the UPS system continues to protect your load. Horizontal modularity Up to 1600 kW with additional 200 kW modules. Trinergy™ can scale up to 1.6 MW in power by adding complete 200 kW UPS modules side-by-side and around the input/output power section. is the ability of...

Open the catalog to page 8
Chloride Trinergy - 9

Three Dimensional Modularity Trinergy™’s three dimensions of modularity allow businesses to expand their power protection needs at the same pace as their evolving load requirements by simply adding additional power modules. These three dimensions of modularity are built around Trinergy’s I/O Box which is the major interface for connectivity and power connections as well as centralized and distributed battery configurations. Modules can be added at anytime during the lifecycle of the UPS

Open the catalog to page 9
Chloride Trinergy - 10

Servicing Critical Infrastructure Proactive equipment maintenance reduces downtime and extends equipment life which in turn maximizes return on investment and increases system availability. Emerson Network Power supports entire critical infrastructures with an extensive service offering, guaranteeing network availability and total peace of mind 24/7. Our approach to servicing critical infrastructure covers all aspects of availability and performance, from single units to entire mission critical systems, providing customers with tailored services to meet their individual business needs and...

Open the catalog to page 10
Chloride Trinergy - 11

System temperature gauge Battery charge indicator Service history logs Hardware Connectivity The touch screen display ensures the monitoring and control of networked UPS, through two different options of the TCP/IP protocol: The integration of UPS with Building Monitoring and Automation Systems via MODBUS RTU, MODBUS/TCP or JBUS protocols The integration of UPS in Network Management Systems through SNMP protocol Software Connectivity Liebert® Nform will monitor the UPS via SNMP protocol. Authenticated alarm management, trend analysis and event notification delivers a comprehensive...

Open the catalog to page 11
Chloride Trinergy - 12

100% uptime: optimum scalability and fast installation and service guarantee maximum load I Input/output I Three phases internal architecture Three phases Faster Installation And Service TrinergyTU's modular design facilitates installation by allowing ideal even for sites with difficult Trinergy can be configured to suit immediate load requirements as additional modules can easily be changing load demands. This feature minimizes initial capital investment and ensures that the UPS system operates at a significant percentage load in order to ensure optimum system Modules are easily accessible...